KYRA'S PEARL

KYRA'S PEARL is a 2007 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in October 2025, along with 75 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 28 October 2025.

Built
2007
Last inspected
28 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 October 2025
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG6051
867542
Flag
UNITED STATES
Maury page id
psix-867542

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEA STALLION Passenger (Inspected) · MISLE 1487342 · 4 October 2023 · activity 7809669KAMANU ELUA Passenger (Inspected) · MISLE 1330311 · 4 November 2019 · activity 6850982

Inspection history · 22

28 October 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8260711
25 October 2024 Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8025445
16 May 2024 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7918650
4 October 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7809669
29 August 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7780783
5 October 2022 Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7572192
27 July 2022 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7518329
13 April 2022 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7429995
13 October 2021 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7332244
28 July 2021 Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7270876
28 October 2020 Internal Structural Exam · In-Service Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7082710
12 November 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6855733
4 November 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6850982
2 November 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6877016
31 October 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6842268
27 August 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6803211
21 November 2018 Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6583897
17 November 2017 Deficiency Check · Hull Examination · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6306317
7 November 2017 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6302505
22 March 2017 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6115407
20 October 2016 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6042435
20 September 2016 Administrative Inspection · Hull Examination · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5996019

Deficiency record · 75

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2025 Resolved
Need to conduct exterior “leak” test on inflatable collar IAW Sector Honolulu Work Instruction 07 to receive credit for COI annual exam. Could not conduct test due to inadequate test equipment. Must complete test to satisfaction of USCG Marine Inspector prior to carrying passengers. **Note: may operate as a six pack vessel until satisfactorily completing test.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 October 2025 Resolved
A vessel not required to have a power-driven fire pump by 46 CFR 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI. Vessel only had 1 fire bucket. Must add two (02) more buckets to inventory.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 October 2025 Resolved
Electrical equipment must be installed and maintained to minimize accidental personnel contact contact. Need to correct the following: -Clean up electrical wire runs under operator's station to minimize electrical hazard..i.e. install wire bands -cap/remove dead end wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2025
Resolved 24 November 2025
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 October 2025 Resolved
All flexible nonmetallic hose for use in vital systems subject to pressures not exceeding 5 PSI must have a minimum of two (02) hose clamps installed at both ends of the hose. Must correct to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2025
Resolved 20 November 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 October 2025 Resolved
All vessels required to have exhaust blowers for gasoline engines/fuel tanks must have a red warning sign at the starting switch that states that the blowers must be operated prior to starting the engines for the time sufficient to insure at least one (01) change of air in the space served (02 minutes). Must replace current sign to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2025
Resolved 29 October 2025
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 28 October 2025 Resolved
A durable, emergency broadcast placard must be posted next to all radio installations to satisfaction of USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2025
Resolved 20 November 2025
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 October 2025 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2025
Resolved 29 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 October 2025 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2025
Resolved 29 October 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 October 2025 Resolved
The Original Certificate of Inspection (COI) and Stability Letter must be kept on board vessel in weather tight container readily available for use by crew and display to passengers. Page two (02) of Original COI and Stability Letter not available during inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2025
Resolved 29 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 October 2025 Resolved
Vessels on limited coastwise routes are required to carry six (06) red and six (06) orange flares or twelve (12) red flares. Vessel had six (06) red flares at the time of the inspection. Must add six (06) more flares for vessel's route. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 28 October 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 October 2025 Resolved
Vessel EPIRBS must be tested monthly and logged. No log entries for EPIRB tests at time of inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 28 October 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2025 Resolved
All vessels that are permitted under their routes and conditions to allow crewmembers to enter the water during snorkeling excursions must adhere to the eligibility requirements under CG Sector Honolulu Work Instruction 31. The following were not available for inspection: -Automated External Defibrillator (AED); Eligibility criteria #5 Must correct or endorsement will be removed from vessel's routes and conditions.
Action required: 705 - Other - as specified
Resolved 28 October 2025
Resolution: COI Endorsement removed from routes and conditions for Sector Hono WI 31 at operator's request.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 28 October 2024 Resolved
All vessels must comply with applicable FCC radio requirements per 47 CFR Part 80. VHF radio o/b vessel not operational at time of inspection. Must make repairs/replace in kind to the satisfaction of the USCG Marine Inspector. Vessel operator must have handheld VHF radio approved by USCG Marine Inspector and conduct radio checks prior to getting underway with passengers until fixed VHF radio replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2024
Resolved 13 November 2024
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 25 October 2024 Resolved
Vessel operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment: -No evidence of annual servicing of 10:BC portable fire extinguisher -No charge on 10:BC portable fire extinguisher -Expired annual servicing on fixed fire system Must rectify to satisfaction of USCG prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 October 2024 Resolved
Vessel operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment: -Missing one (01) 40:BC portable fire extinguisher as required by Certificate of Inspection (COI). Must rectify prior to satisfaction of USCG prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 October 2024 Resolved
USCG did not get underway with vessel crew to conduct drills due to inadequate fire fighting systems. Vessel crew required to get underway and conduct drills in presence of USCG inspector prior to receiving credit for annual exam.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2024
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 October 2024 Resolved
Provisions must be made for closing all supply duct cowls protected by fixed gas system. All closure devices must be readily available: -missing closure handle for louver for air supply cowl to fuel tank space. Must correct to satisfaction of USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2024
Resolved 29 November 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 October 2024 Resolved
One (01) adult lifejacket was removed from service due to overall substandard condition. Vessel operator required to change max passenger count to eleven (11) until new adult lifejacket is added to satisfaction of USCG.
Action required: 705 - Other - as specified
Resolved 28 October 2025
Resolution: Verified during 2025 annual exam.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 25 October 2024 Resolved
Fire, abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Logged drills not available for inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2024
Resolved 26 November 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2024 Resolved
Although power high level bilge alarm and pump not required for vessel. Both entities not functional due to inadequate electrical wiring. All wiring of systems must be installed to satisfaction of USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2024
Resolved 29 November 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 October 2024 Resolved
Vessel operator must provide up-to-date drug prevention enrollment for vessel crew members. Current enrollment has been expired since January 2024. Two (02) out of the three (03) crew members present for inspection not on current enrollment. Must correct to satisfaction of USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2024
Resolved 26 November 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 August 2023 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy was cracked and separating, must replace buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2023
Resolved 30 August 2023
Resolution: New ring bouy installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2023 Resolved
A flammable vapor detection system must provide a visual and audible alarm at the operating station. Detector not operational, must replace and test with CG inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2023
Resolved 30 August 2023
Resolution: Replaced detector and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2023 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The vessel's fuel shutoff valve was not operable and seized, must replace valve and conduct function test with CG inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2023
Resolved 30 August 2023
Resolution: New valve installed and tested.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 August 2023 Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located at or near the space where the extinguishing agent cylinders are stored. No instructions posted, must post instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2023
Resolved 30 August 2023
Resolution: Instructions are now posted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2023 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets with an attached lanyard satisfactory to the cognizant OCMI. Vessel missing 2 fire buckets, must supply vessel with 2 fire buckets.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2023
Resolved 30 August 2023
Resolution: 2 new buckets installed onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2023 Resolved
A red warning sign at the switch must state that the blowers must be operated prior to starting the engines for the time sufficient to insure at least one complete change of air in the space served, no placard present, must install placard.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2023
Resolved 30 August 2023
Resolution: placard posted
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 August 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Placard missing; post placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 30 August 2023
Resolution: placard installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2023 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Vessels remote fuel shutoff station labeling is missing letters, must re-stencil.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 30 August 2023
Resolution: labeled correctly
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 August 2023 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessels alcohol test strips not onboard. Must acquire test strips and verify with CG inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 30 August 2023
Resolution: approved test strips onboard
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 August 2023 Resolved
The employer shall provide an Employee Assistance Program for all crewmembers that includes both education and training on the effects and consequences of drug and alcohol use. Supervisory personnel must receive at least 60 minutes of training. Vessel O/O must establish an Employee Assistance Program as part of the company's chemical testing program. Provide satisfactory evidence of an Employee Assistance Program to CG inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 30 August 2023
Resolution: EAP established
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 August 2023 Resolved
Except as provided in 80.13(c), stations must have an authorization granted by the Federal Communications Commission. Vessel could not produce current FCC station license during annual inspection. Present current FCC license to CG inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 30 August 2023
Resolution: Owner presented valid FCC license
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 29 August 2023 Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, compass must be illuminated installed. Vessel restricted to daytime operation. Provide light for the compass.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 30 August 2023
Resolution: compass is now illuminated
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 August 2023 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. No broadcast placard present, must affix placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 30 August 2023
Resolution: placard posted
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 August 2023 Resolved
Firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and general description of the drill scenario and training topics. Vessel unable to provide logs for fire fighting drills and training. No logs provided, must conduct training and drills and show documentation to CG inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 30 August 2023
Resolution: Vessel owner conducted fire fighting drill with the crew and documented the drill.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 August 2023 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and scenario and training topics. Vessel unable to provide drill/training logs, must conduct training and drills and show documentation to CG inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 30 August 2023
Resolution: Owner conducted man overboard and abandon ship drill with the crew and documented the drills.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 October 2022 Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer’s instructions. Fireboy needle indicator gauge is outside the green and not serviced.
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Due 5 November 2022
Resolved 20 January 2023
Resolution: Vessel installed fixed mounted portable CO2 extinguisher with smoke detection system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 October 2022 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. No fuel shutoff valve at the tank.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2022
Resolved 21 December 2022
Resolution: Verified installation of fuel shutoff at the fuel tank.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 October 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to prevent electrical ignition of flammable vapors. Batteries and electrical wirings were located in same compartment as gasoline fuel lines and valves and exhaust blower electrical connections were wire nuts and duck tape.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2022
Resolved 21 December 2022
Resolution: Batteries removed to another location and all electrical wiring relocated outside the compartment.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 October 2022 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Ventilation intake duct opening for gasoline fuel compartment did not have closing devices keep gas extinguishing system from escaping.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2023
Resolved 20 January 2023
Resolution: Ventilation closures provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 October 2022 Resolved
A vessel must carry one floating waterlight unless it is limited to daytime operations. The waterlight is extinguished; must replace the battery in the waterlight for the ring life buoy; vessel limited to daytime operations only until waterlight is operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2023
Resolved 20 January 2023
Resolution: New battery installed and waterlight operational.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 October 2022 Resolved
The master may allow reduced crew for limited or special operating conditions subject to the approval of the OCMI. In accordance with Sector Honolulu Work Instruction 31, reduced manning, the deckhand may enter the water while moored or at anchor during in-water passenger activity if provisions in the instruction are met; vessel not equipped with AED with adult and child pads. Vessel is not authorized to have the deckhand enter water until AED with adult and child pads onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2023
Resolved 20 January 2023
Resolution: AED, adult and child pads onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 October 2022 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant OCMI. No fire buckets onboard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2023
Resolved 20 January 2023
Resolution: 3 fire buckets of 2.5 gal provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 October 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Vessel does not have all around 360 masthead light.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2023
Resolved 20 January 2023
Resolution: All around 360 degree mast light provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 October 2022 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Port RPM gauge not functional.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2023
Resolved 20 January 2023
Resolution: New working RPM gauge provided for port engine.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 October 2022 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. No procedure to catch fuel spill onboard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2023
Resolved 20 January 2023
Resolution: Procedure and absorbent pads provided during fueling operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 July 2022 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy is worn, ring buoy light does not work and did not have the line attached. Replace life ring buoy and ring buoy light with line attached.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2022
Resolved 28 July 2022
Resolution: Verified installation of new life buoy with line and working water light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 July 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 05 adult life jackets were flattened and unserviceable. Provide 5 additional adult lifejackets. Vessel is limited to carry 9 persons onboard.
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Due 27 July 2022
Resolved 27 July 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 July 2021 Resolved
Exhaust blower switches must be located outside of any space required to be ventilated and must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. The vessel's blowers were found to not be interlocked with starting switch.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 August 2021
Resolution: The vessel's blowers were interlocked with starting switch.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 July 2021 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The vessel’s fire dampener on the mechanical means of exhaust would not close. Provide proper closure device for exhaust.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 August 2021
Resolution: Provided proper closure device for exhaust.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 28 July 2021 Resolved
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. The engine’s fuel and electrical lines that penetrate the deck going into the fuel space does not have any means to prevent water from entering the space. Replace or repair the watertight gasket around the deck penetrations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 August 2021
Resolution: Replaced the watertight gasket around the deck penetrations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 July 2021 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Repair or replace the vessel’s floating waterlight.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 August 2021
Resolution: Replaced the vessel’s floating waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 July 2021 Resolved
Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry six hand red flare distress signals and six hand orange smoke distress signals. Provide the required type and amount of flares.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 August 2021
Resolution: Provided the required type and amount of flares.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 July 2021 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Place emergency fuel shut off placard by the fuel shut off valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 August 2021
Resolution: Placed emergency fuel shut off placard by the fuel shut off valves.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 July 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. (List found in 46 CFR 160.041-4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 August 2021
Resolution: A new first-aid kit was purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 July 2021 Resolved
A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. One of the four required child life jackets was removed due to the poor condition. One child life jacket needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 August 2021
Resolution: One child life jacket was replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 July 2021 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below. The vessel needs to conduct the overpressure "stress" test IAW Sector Honolulu Work Instruction 07.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 August 2021
Resolution: The vessel conducted the overpressure "stress" test IAW Sector Honolulu Work Instruction 07.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 October 2020 Resolved
An exhaust blower motor may not be installed in a duct, and if mounted in any space required to be ventilated by this section, must be located as high above the bilge as practicable. The vessel has an in-line blower installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 10 November 2020
Resolution: Vessel changed the in-line blower with a CG approved blower, 120 CFM.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 October 2020 Resolved
Each ring buoy on a vessel must be approved in accordance with 46CFR 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. The ring life buoy was found to be damaged by UV exposure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 10 November 2020
Resolution: Owner replaced ring buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 October 2020 Resolved
A flexible tube or hose may be used instead of fixed pipe for the discharge line of a submersibel electric bilge pump provided the hose or tube does not penetrate any required water-tight bulkhead and is of good quality and of substantial construction, suitable for the intended use. Vessel's forward bilge pump tubing has a pinhole leak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 10 November 2020
Resolution: The hose was replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 October 2019 Resolved
Provide visual alarm/indicator light for fixed gas fire system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2019
Resolved 18 November 2019
Resolution: Provided visual alarm/indicator light for fixed gas fire system.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 October 2019 Resolved
Port aft and starboard FWD baffle drop from 3 PSI to less than 2.5 PSI to less than 2/5 PSI during the 15 minute test. Both Baffles have to hold pressure. Repair baffles as needed to hold/pass pressure test. Sector Honolulu Work Instruction #7.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2019
Resolved 12 November 2019
Resolution: Marine Inspector verified successful over inflate / baffle pressure tests.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 November 2018 Resolved
Provide a working visual/audible indicator for the vapor detection sensor at the helm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 18 December 2018
Resolution: Marine Inspector verified working visual/audible alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 21 November 2018 Resolved
Provide proof of having a consistently powered float water light for the vessel ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 18 December 2018
Resolution: Marine Inspector verified float water light for ring buoy functions properly.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 November 2018 Resolved
Provide proof of carrying all required medicines for the vessel's onboard first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 18 December 2018
Resolution: Marine Inspector verified all required medicines onboard were valid.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 21 November 2018 Resolved
Install a oil discharge placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 18 December 2018
Resolution: Marine Inspector verified oil discharge placard onboard vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 November 2018 Resolved
Provide proof of carrying the applicable coast pilot publication.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 18 December 2018
Resolution: Marine Inspector verified Coast Pilot publication is onboard vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2018 Resolved
Vessel needs to provide the hailing port in block letters on the transom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 18 December 2018
Resolution: Marine Inspector verified hailing port labeled on transom
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 November 2018 Resolved
Re-label/mark the quanity and location of all adult life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 18 December 2018
Resolution: Marine Inspector verified life jacket markings were re-labeled and marked appropriately.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 17 November 2017 Resolved
Vessel needs to have an operational vapor detection system installed onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 7 December 2017
Resolution: A vapor detection system was installed onboard.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 November 2017 Resolved
Vessel needs to ensure bilge pumps operate in both automatic and manual mode of operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 7 December 2017
Resolution: The companny ensured bilge pumos operate in both automatic and manual modes.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 November 2017 Resolved
Vessel needs to clearly mark stowage location and quantity of onboard child lifejackets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 7 December 2017
Resolution: The company marked the number and location of lifejackets oboard the vessel.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 September 2016 Resolved
Vessel needs to be equipped with the proper navigational light arrangement required for night operations. 46 CFR 183.420 Restricted to daylight operations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 September 2016
Resolved 20 October 2016
Resolution: Vessel made proper lighting arrangements for conducting night dive/snorkel operations. NAV RULE 27
Engineering › Bilge Water Management System › Not Operational
Issued 20 September 2016 Resolved
Bilge pumps need to be able to be controled from a central control station emitting a light to indicate the pump is functioning. 46 CFR 182.520
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 20 October 2016
Resolution: Vessel rep showed proper operation of bilge pump operation from light emitting from central control station.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 September 2016 Resolved
Vessel needs to have functioning light and audible indicators to show satisfactory discharge of the pre-engineered fixed gas fire extinguishing system. 46 CFR 181.420
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 20 October 2016
Resolution: Verified fire technician arranged the fixed fire extinguishing so that the audible and visual indicators emit from the control station.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.