Records from 2007 to 2023. Most recent: inspection, 14 June 2023.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWEST GULF MARINE LTD · GALVESTON, TX, UNITED STATES · built 2007
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 April 2026 · expires 30 April 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
14 June 2023
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7715197
24 May 2023
Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7695969
11 February 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6638881
9 May 2018
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6409798
19 April 2018
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6395030
20 June 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6199929
10 August 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5968698
18 August 2015
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5225410
4 August 2015
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5758281
26 May 2015
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5136462
11 August 2014
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4948179
2 July 2014
Permit to Proceed · Damage Survey · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4909931
2 July 2014
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4915360
11 June 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4945042
11 June 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4974290
4 June 2013
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4610172
11 July 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4421056
10 January 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4263705
24 September 2010
SIP Initial Entry
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3856418
14 September 2010
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3849517
7 January 2010
SIP Inspection/Audit
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3856560
22 August 2009
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3575228
8 April 2009
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3563209
17 March 2008
Initial Certification · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3165904
10 December 2007
Construction Oversight · Hull Examination · Internal Structural Exam · Spot Check · Cargo Tank Internal
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3112939
6 February 2007
Construction Oversight · Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2867660
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 August 2015
Resolved
Navigation light screens need to be repainted flat black
Condition: Improper/Lack of Maintenance
Due 4 September 2015
Resolved 4 August 2015
Resolution: Navigation light screens repainted flat black
Construction/Loadline › Hull › Hull Plating
Issued 2 July 2014
Resolved
Vessel suffered hull damage after bridge allision. Specific damage as follows: stbd #4 wing void suffered 2 fractures at deck gunnel, the 1st measured approx 3' X 1", the 2nd measured 18" X 1/2". The stbd #5 wing void suffered tear at the deck gunnel measuring approx 10" X 6" and sharp hull inset at aft blkhd measuring approx 7" X 2". The stbd #6 wing void suffered minor inset measuring 20' X 1/2"
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 August 2014
Resolved 18 August 2014
Resolution: Witness sat repair of forward damage 11 AUG, and sat repair of aft areas 18 AUG. Soap/air test of all insert areas.
Construction/Loadline › Hull › Transverse Frame
Issued 10 December 2007
Resolved
Prior to operating, vessel (barge) owner/operator must demonstrate that barge has been built according to sistered approved plans (i.e. welded padeyes to transverse floor framing IAW plans/approved ltrs.)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 December 2007
Resolution: Received correspondence from Naval Architect [name withheld] and Associates attesting to no loss of structural integrity to subject barge with attached padeyes to floor framing.