MAURY USCG vessel records
← All vessels

RANDY J

RANDY J is a 2007 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in December 2025, along with 21 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2013.

Records from 2013 to 2025. Most recent: inspection, 15 December 2025.

Built
2007
Last inspected
15 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 December 2025
…with no type recorded3
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD9484
874503
Flag
UNITED STATES
Maury page id
psix-874503

Documentation record

Registered dimensions (L × B × D)147.5 ft × 29.5 ft × 10.8 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)147.5 ft × 29.5 ft × 10.8 ft
ITC tonnagegross 341 / net 102
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 2007
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portERATH, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 11 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it341 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
102 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

21 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; 2 vessels inspected with it, by name and date; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ENTERPRISE 205 Mobile Offshore Drilling Unit · MISLE 51209 · 25 October 2018 · activity 6568770C-PERFORMER Offshore Supply Vessel · MISLE 508515 · 25 October 2018 · activity 6568770

Inspection history · 21

15 December 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8275628
4 December 2025 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8267644
10 December 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8045528
17 November 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7826551
3 November 2023 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7819944
12 September 2022 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7547068
2 December 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7360240
29 November 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7358400
15 October 2021 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7333300
17 May 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7200293
11 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110291
9 December 2020 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108821
18 October 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6837537
12 September 2019 Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6810950
25 May 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6716993
6 November 2018 Annual Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6575246
25 October 2018 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6568096
25 October 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6568770
5 September 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6259649
31 August 2017 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6256349
28 November 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6048676

Deficiency record · 21

10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 10 December 2024 Resolved
A vessel with a power driven main steering gear must be provided with an independent rudder angle indicator. The rudder angle indicator in aft steering was stuck at 20 degrees rudder angle.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2025
Resolved 11 December 2024
Resolution: RAI fixed and tested.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2024 Resolved
Electrical equipment used in a machinery space must be drip proof. The battery box in the engine room contained built up water and corrosion in it.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2024
Resolved 11 December 2024
Resolution: Cleaned up. Water was from washing down.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 December 2024 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The vents onboard were damaged and no longer allowed the closure devices to fit properly.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2025
Resolved 11 December 2024
Resolution: Bent sections replaced, verified operation.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 10 December 2024 No resolution recorded
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The service tank containing hydraulic oil had a slow leak with a temporary repair.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 November 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 December 2024 Resolved
A drip pan fitted with flame screen must be installed under gasoline strainers. Fuel filters fitted with bowls of other than steel construction must meet ASTM F1201. The drip pan bowl was missing from the filter.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2024
Resolved 11 December 2024
Resolution: Flame screen replaced.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 22 November 2023 Resolved
All vessels with overnight accommodations must be equipped with a general alarm system. General alarm was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 November 2023
Resolution: General alarm light was replaced and satisfactorily tested.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 November 2023 Resolved
Each survival craft must be: stowed in a way that neither the survival craft nor its stowage arrangements will interfere with the operation of any other survival craft. Life float line connecting life floats to one another was frayed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 November 2023
Resolution: Life float line was replaced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 November 2023 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard. EPIRB tests required monthly shall be logged or or otherwise documented. Crew drills and EPIRB maintenence tests were not logged. Crew logged drills and EPIRB tests conducted during the inspection.
Action required: 10 - Deficiency Rectified
Resolved 22 November 2023
Resolution: Crew logged drills that were conducted during the inspection. Additionally, crew documented EPIRB test that was conducted during the inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 September 2022 Resolved
Bilge piping must be 1.5 in nominal pipe size. E/R bilge suction line wasted and found w/ temp repair.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2022
Resolved 12 September 2022
Resolution: Verified piping repairs prior to vessel departure.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 12 September 2022 Resolved
Hinged water tight bulk head door must be fitted. E/R, Galley, Generation Compartment and Rudder Room not water tight. Adjust WTD's.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2022
Resolved 12 September 2022
Resolution: Adjusted WTD's, MI verified prior to departure.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 September 2022 Resolved
Up to date charts required for intended voyage. Charts last updated 2021.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2022
Resolved 14 September 2022
Resolution: New charts onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 September 2022 Resolved
F/O remote shutoff stations must be marked w/ letters at least 1 in and direction of operation. Port and Stbd stations not marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 14 September 2022
Resolution: F/O reach rods marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2022 Resolved
Piping used in vital systems must be composed of ferrous materials. Temp patch on jacket water pipe #3 M/E.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2022
Resolved 21 September 2022
Resolution: New Cat parts-Tube, Rings and o-rings installed.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 29 November 2021 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties. Each fire drill must include: Instruction in the use and location of fire alarms, extinguishers, and any other fire fighting equipment on board. When questioning the deckhand on previous training and knowledge for operating the vessels fixed CO2 system, the deckhand had not received instruction nor had knowledge of the operation of the system. Vessel shall ensure all crewmembers are familiar with operating the fixed CO2 system prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2021
Resolution: Vessel provided proof of system training.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 29 November 2021 Resolved
A vessel of more than 65 feet in length must carry at least one rescue boat unless the cognizant OCMI determines that: The vessel is sufficiently maneuverable, arranged, & equipped to allow the crew to recover a helpless person from the water. While conducting a man overboard drill the crew was unable to produce a safety line for the harness and thus not able to safely recover a helpless person from the water. Vessel shall provide a safety line for the rescue harness prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2021
Resolution: Vessel provided safety line for harness.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 November 2021 Resolved
A hinged watertight bulkhead door must be fitted with a quick action closing device operable from both sides of the door... Watertight door leading to machinery space was not able to fully close and thus inoperable. Vessel shall repair watertight door leading to machinery space prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2021
Resolution: Vessel repaired door to the satisfaction of attending MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 November 2021 Resolved
Flexible nonmetallic hose may be used in lube oil, fuel oil & fluid power systems, subject to the following requirements: Flexible hose installed in lengths of not more than 30 inches. Both Port & Stbd generators have more than 30 inches of flexible nonmetallic hose installed on the fuel lines. Vessel shall make Port & Stbd generators to have not more than 30 inches of flexible nonmetallic hose installed on the fuel lines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2021
Resolution: Vessel repaired hoses to the satisfaction of the attending MI
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 November 2021 Resolved
A weathertight door must be provided for each opening located in a deck house or companionway. Gasket material around main deck weathertight door was missing around two of the corners. Vessel shall install new gasket material to make main deck door weathertight prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2021
Resolution: Door was reapired to satisfaction of attending MI
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 18 October 2019 Resolved
The float-free link required by 180.130(a)(1) must be: Secured to the painter at one end and to the vessel at the other end; Lifefloat not secured; Secure as per 46 CFR 180.137(b)(3); To the satisfaction of the Coast Guard by 22OCT19.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2019
Resolved 21 October 2019
Resolution: Accepted pictures of repair, showing all lifefloats attached to single weak-link secured together.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 October 2019 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or a any space into which carbon dioxide might migrate must be conspicuously marked in accordance with 46 CFR 185.612(g)(1) and (2); Placards were not present; Provide placards as per 46 CFR 185.612(g)(1) and (2); To the satisfaction of the Coast Guard by 22OCT19.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 October 2019
Resolved 21 October 2019
Resolution: Accepted photos of CO2 placards posted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 October 2019 Resolved
Each pressure type wire connector and lug must can utilize twist-on type wire nuts under the following conditions: The connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Junction box was not present; Provide junction box as per 46 CFR 183.340(i)(1) and 46 CFR 183.200(b); To the satisfaction of the Coast Guard by 22OCT19.
Action required: 10 - Deficiency Rectified
Due 22 October 2019
Resolved 21 October 2019
Resolution: Accepted photo of repaird junction box.

Casualty record · 1

3 December 2013Routine · role: Acknowledged Pollution Source · activity 4764155
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.