Records from 2000 to 2026. Most recent: inspection, 13 February 2026.
Inspection history · 46
13 February 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8299415
11 December 2024
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8035395
12 November 2024
Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8031797
29 February 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7872004
30 August 2023
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7783178
30 January 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7628920
4 January 2023
Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7611525
16 February 2022
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7397208
9 February 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7137842
6 January 2020
COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6883165
21 November 2019
Cargo Tank Internal · Hull Examination · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6859718
8 November 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6851952
8 January 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6612249
30 October 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6571443
25 October 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6568770
2 May 2018
Administrative Inspection · Annual Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6404235
17 April 2018
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6399553
1 February 2017
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6080802
11 February 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6079902
17 March 2014
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4817590
12 March 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4814257
11 March 2014
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4816054
30 July 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4397049
23 February 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3950853
17 December 2010
Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3662202
19 January 2010
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3666409
16 March 2009
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3443679
14 April 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3189003
24 March 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3213451
18 January 2008
Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3134335
24 April 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2919028
16 August 2006
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2750053
17 March 2006
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2604188
26 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501707
17 February 2005
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2294282
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2294007
18 January 2005
Internal Structural Exam · Hull Examination · Cargo Tank Internal · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2276526
19 May 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2072266
3 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979601
10 March 2003
Cargo Tank Internal · Underwater Inspection in lieu of Drydock · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1756508
3 May 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1612315
5 April 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1604187
5 June 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471769
2 June 2001
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 487813
13 March 2000
Initial Certification · Initial Construction-Excluding Oversight · Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458734
9 January 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 814496
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 December 2024
Resolved
Each hatch exposed to the weather must be watertight.
ER escape hatch had visible light coming through in aft corner when secured.
46 CFR 174.220(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2024
Resolution: Received proof of repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2024
Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to protect crew members, offshore workers from electrical hazards.
MI's found exposed electrical contacts on #1-S ballast fill valve & broken lamp cover above emergency generator.
46 CFR 174.220(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2024
Resolved 13 December 2024
Resolution: Received proof of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 December 2024
Resolved
Suitable covers, guards, or rails must be installed on each exposed and dangerous place, such as hot surfaces.
Exhaust lagging was removed from bow thruster engine.
46 CFR 127.330
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2024
Resolved 13 December 2024
Resolution: Received proof of replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 February 2024
Resolved
A rescue boat is not required for a vessel operating on the continental shelf of the United States, if the OCMI determines the vessel is arranged to allow a helpless person to be recovered from the water. The on board rescue platform (in lieu of rescue boat) is too large to safely operate/maneuver. Alter/replace rescue platform by the vessel's next dry dock inspection.
- 46 CFR Part 133.135(c)
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 11 December 2024
Resolution: Platform reduced so 1 person can deploy. Ran MOB drill, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 January 2023
Resolved
Nothing in this part shall limit the inspector from inspections deemed necessary to assure the safety of the vessel. STBD Fuel Oil line is wearing through due to loose clamp. Replace fuel oil line.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2023
Resolved 15 March 2023
Resolution: Rcvd photos of the new installed fuel line.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 January 2023
Resolved
Each entrance to a space storing or protected by CO2 must be marked. Paint locker CO2 cylinder storage and paint locker are not marked.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 January 2023
Resolved 30 January 2023
Resolution: Vessel Crew properly marked the space IAW 46CFR131.817
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 January 2023
Resolved
Each OSV must be equipped with portable fire extinguisher. Fire extinguisher #25 has a broken nozzle.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2023
Resolved 10 February 2023
Resolution: Vsl rep provided proof of new fire extinguisher onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 January 2020
Resolved
Before any vessel leaves protected waters, the master shall ensure that the vessel’s exposed cargo hatches and other openings in the hull are made properly watertight by the use of gaskets or similar devices. Adjust Forward/Aft Escape Hatches. Replace gaskets on aft escape hatch and all internal machinery watertight doors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2020
Resolution: Cleared to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 January 2020
Resolved
Nonmetallic flexible hoses may be used in lube oil, fuel oil and fluid power systems only where flexibility is required and in lengths no exceeding 30 inches. Inspectors observed corroded supply and return diesel fuel lines on both MDEs. Replace supply and return diesel fuel lines on both MDEs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2020
Resolution: Cleared to satisfaction of MI.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 January 2020
Resolved
The exterior boundaries of superstructures containing accommodations, service and control spaces, and facing the cargo area must be protected by A-60 boundaries and divisions. Adjust self-closing fire doors in galley and stairwell leading to bridge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2020
Resolution: Cleared to satisfaction of MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 January 2020
Resolved
Before any vessel leaves protected waters, the master shall ensure that the vessel’s openings in the hull are made properly watertight by the use of gaskets or similar devices. Replace rox blox for penetration on starboard steering compartment bulkhead.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2020
Resolution: Cleared to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2020
Resolved
Vital systems are those systems that are vital to a vessel’s survivability and safety. Emergency electrical generation systems are defined as a vital system and the inspectors observed a noticeable leak from the Raycor diesel fuel filter installed. Replace Raycor diesel fuel filter on emergency generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2020
Resolution: Resolved to satisfaction of MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 January 2020
Resolved
Before any vessel leaves protected waters, the master shall ensure that the vessel’s openings in the hull are made properly watertight by the use of gaskets or similar devices. Replace inboard seal on bow tunnel thruster.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2020
Resolution: Resolved to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2020
Resolved
Nonmetallic flexible hoses may be used in lube oil, fuel oil and fluid power systems only where flexibility is required and in lengths no exceeding 30 inches. Inspectors observed corroded fuel lines on starboard MDE centripetal oil purifier system. Replace fuel line on starboard MDE centripetal oil purifier system.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2020
Resolution: Resolved to satisfaction of MI.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 January 2020
Resolved
All systems for detecting smoke and fire, including sensors and alarms, must be inspected and tested annually. Fault on fire detection and alarm panel, STBD aft cargo area smoke alarm. Cleared by 3rd party rep while inspectors were on board.
Action required: 10 - Deficiency Rectified
Resolved 6 January 2020
Resolution: Cleared to satisfaction of attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2018
Resolved
PROVIDE (2) PROPER RING BOUYS
Action required: 60 - Rectify deficiencies prior to movement
Due 31 October 2018
Resolved 8 November 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 October 2018
Resolved
PROVIDE CLASS 1 DIVISION 1 LIGHT IN PAINT LOCKER
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2018
Resolved 8 November 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 30 October 2018
Resolved
REMOVE ALL ACCESS OIL FROM BILGE
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2018
Resolved 8 November 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 30 October 2018
Resolved
PROVIDE PROPER WORKING VALVE ON OILY WATER SEPARATOR #1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2018
Resolved 8 November 2018
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 30 October 2018
Resolved
PROVIDE PROPER WORKIONG SANITARY WATER SYSTEM OR LOCK OUT TAG OUT
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2018
Resolved 6 November 2018
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 May 2018
Resolved
Demonstrate the ability to recover a helpless person from the water.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 May 2018
Resolution: Crew completed sat drill
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 2 May 2018
Resolved
Provide operational fire detector in ECR
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 17 May 2018
Resolution: Tested detector with smoke, all sat.
Deck/Cargo › Holds/Tanks › Watertight Door
Issued 2 May 2018
Resolved
Provide repairs to watertight doors
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 17 May 2018
Resolution: Replaced gasket material, all sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 May 2018
Resolved
Provide Emergency lighting in E-gen space
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 May 2018
Resolution: Light battery replaced.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 2 May 2018
Resolved
Provide ground detection in swithcboard
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2018
Resolution: Witnessed function test of the ground fault detection and meter, all sat.
Engineering › Thrusters › Hose
Issued 2 May 2018
Resolved
Provide repairs to hydraulic connections in propulsion system (bow thruster)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2018
Resolution: The hydraulic lines on the fwd bow thruster were replaced, all sat.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 2 May 2018
Resolved
Provide line diagram and fuel transfer procedures
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2018
Resolution: Both ar now posted at the manifold.
Operations/Management › Pollution › Control of Garbage
Issued 2 May 2018
Resolved
Provide MARPOL V placard for garbage macerator in laundry room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 May 2018
Resolution: Placard is posted at the pump controls.
Navigation › Piloting/Steering › Marine Charts
Issued 1 February 2017
Resolved
Each vessel must carry adequate and up to date nautical charts and nautical publications. Vessel is not equipped with charts and nautical publications. Provide charts and publications on board to the satisfaction of attending USCG MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2017
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 1 February 2017
Resolved
Vessel has not conducted NT-VRP drills, exercises, or QI notifications IAW USCG approved NT-VRP. Provide proof of following all elements of NT-VRP to the satisfaction of USCG MI.
Due 4 February 2017
Resolved 3 February 2017
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 1 February 2017
Resolved
The transfer procedures required by 33CFR155.720 are to include a line diagram of the transfer system. Vessel's transfer procedures lack a line diargam. Proved on board a complete set of transfer procedures to the satisfaction of attending USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2017
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 1 February 2017
Resolved
The respective piping systems on a vessel shall be made safe and efficient for operation. Flexible fuel hose on STBD generator found severly deteriorated. Repair/replace to the satisfaction of attending USCG MI.
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 3 February 2017
Operations/Management › Drills/Instruction › Fire
Issued 1 February 2017
Resolved
Crew could not conduct a satisfactory fire drill. Conduct a satisfactory fire drill in the presence of attending USCG MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2017
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 March 2014
Resolved
Provide self closing fire door in engine room vestibule/fiddly space.
Due 12 March 2014
Resolved 12 March 2014
Resolution: Adjusted door to it now closing.
Documentation › Markings/Placards › Garbage Placard
Issued 12 March 2014
Resolved
Provide new MARPOL V placard
Due 31 March 2014
Resolved 12 March 2014
Resolution: New MARPOL V placard provided.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 March 2006
Resolved
Provide 3rd party servicing for OWS prior to 17Apr06 to the satisfaction of an attending Marine inspector.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 22 March 2006
Resolution: 3rd party documentation provided.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 17 March 2006
Resolved
Provide spare SCBA cylinder.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 22 March 2006
Resolution: Provided spare bottle.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 March 2003
Resolved
PROVIDE PROPER BATTERY INSTALLATION FOR BATTERIES LOCATED AT 02 LEVEL VENTILATION SPACE.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 20 May 2004
Resolution: Batteries were relocated to a weathetight box on the main deck. All satisfactory.
Communications › Radio Communications › EPIRB
Issued 10 March 2003
Resolved
PROVIDE NEW PULL CLIP FOR EPIRB RELEASE.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 11 March 2003
Stability › Watertight Integrity
Issued 10 March 2003
Resolved
RENEW GASKET ON AFT MESSDECK WATERTIGHT DOOR. LEGACY COMPONENT DESC: WATERTIGHT DOORS
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2003
Resolved 11 March 2003
Lifesaving › Line-Throwing Appliances › Lines
Issued 3 May 2002
Resolved
PROVIDE PROPER AMOUNT OF MESSENGER LINE FOR LINE THROWING APPARATUS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 June 2002
Resolved 6 May 2002
Engineering › Bilge Water Management System › Valve
Issued 3 May 2002
Resolved
REPAIR FOREPEAK REMOTE REACH ROD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2002
Resolved 3 May 2002
Engineering › Thrusters › Hose
Issued 3 May 2002
Resolved
PROVIDE AND INSTALL CHAFFING GEAR ON STARBOARD Z-DRIVE FLEXIBLE HOSES.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 June 2002
Resolved 3 May 2002
Communications › Internal Communications System › Sound-powered Telephone
Issued 3 May 2002
Resolved
REPAIR Z-DRIVE ROOM SOUND POWERED PHONE VISUAL INDICATOR.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 June 2002
Resolved 3 May 2002
Construction/Loadline › Hull
Issued 3 May 2002
Resolved
MAKE PERMANENT REPAIRS TO BOW AND BOW BUL WARKS. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 June 2002
Resolved 3 May 2002