Inspection history · 53
16 February 2026
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8308049
7 August 2025
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8204475
16 February 2025
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8076232
10 February 2025
Security Breach
Type not classified · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8077900
30 December 2024
Security Breach
Type not classified · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8057054
23 November 2024
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8038976
18 August 2024
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7979465
12 August 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7979350
18 February 2024
COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7866154
3 September 2023
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7807033
20 August 2023
Deficiency Check · COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7768881
29 July 2023
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7789441
19 February 2023
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7638261
10 February 2023
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7634937
21 November 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7597602
27 August 2022
PSC A · Ballast Water Examination · COC-CVE Annual · ISPS Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7542354
15 May 2022
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7457552
26 March 2022
COC-CVE Quarterly · Ballast Water Examination · ISPS Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7418118
15 March 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7412045
12 September 2021
COC-CVE Annual · PSC A · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7310549
22 May 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7203525
22 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6942577
10 April 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6937853
10 April 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6944534
4 April 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6935469
15 January 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6907195
28 October 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6844803
10 October 2019
ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6831283
30 September 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6832027
24 August 2019
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6794944
23 August 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6809331
19 August 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6789658
18 July 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6759372
14 April 2019
Ballast Water Examination · ISPS III Exam · COC-CVE Quarterly
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6660372
6 April 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6725226
30 December 2018
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6603950
14 October 2018
ISPS III Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6560758
10 April 2018
Ballast Water Examination · COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6388697
3 April 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6399317
25 March 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6380758
28 November 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6315872
15 October 2017
COC-CVE Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6286864
7 October 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6284967
12 September 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6266528
5 September 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6262483
23 April 2017
COC-CVE Quarterly · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6129756
28 February 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6097954
13 February 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6088349
13 November 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6040933
27 October 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6030845
24 October 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6050050
16 October 2016
ISPS III Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6022456
24 April 2016
ISPS III Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5857681
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 August 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed lifeboat 8 unable to start. A 17C was issured on the form B and then cleared on the spot. Ships force found that the batteries was drained on voltage and would not take charge from the charger. ships force replaced with new spare batteries onboard.
74 SOLAS 20 III/20.2
11129 Deficiency code
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2023
Resolution: Resolved prior to departure. Ships force found that the batteries was drained on voltage and would not take charge from the charger. ships force replaced with new spare batteries onboard.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 20 August 2023
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed crew assigned to Liferaft Station 1 not familiar with procedures for moving davit in case of loss of power.
A 17c was issued. PSCO witnessed the training that was given to Liferaft station 1. The liferaft station then performed from memory their duties to launch the liferaft correctly to the [name withheld] then cleared the deficincy on the Form B
74 SOLAS 20 III/19.2.1
04110 Deficiency code
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2023
Resolution: PSCO witnessed the training that was given to Liferaft station 1. The liferaft station then performed from memory their duties to launch the liferaft correctly to the [name withheld] then cleared the deficincy on the Form B
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 August 2023
Resolved
The Load Line ring, lines and letters shall be painted white or yellow on a dark background or in black on a light background. They shall also be permanently marked. PSCO observed load line marking not painted in color contrasting hull background color. Staff captain had ships force repaint the load line because of this PSCO issued a 10c
Load Line Convention 66 I/6
03199 Deficiency code
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 August 2023
Resolution: Rectified, Staff captain had ships force repaint the load line because of this PSCO issued a 10c
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 February 2023
Resolved
Every crew member with assigned emergency duties shall be familar with these duties before the voyage begins. During the abandon ship drill PSC observed 02 stairway guides did not know where the fire extinguishers were located, and the 2nd coxswain for lifeboat 7 did not know how to turn on the batteries to start the life boat. 74 SOLAS 20 II/19.2.2 DEF code 10C
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 19 February 2023
Resolved 19 February 2023
Resolution: Saftey officer conducted onsite training with the crew
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 February 2023
Resolved
The Means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The markings must enable passengers to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. PSC observed 02 sections of low location lighting were flickering on and off and would remain off for extended amounts of time on 01 MVZ 03 stb side, and on deck 07 MVZ 05 portside. 74 SOLAS 20 II-2/13.3.2.5.1 code 7120 action code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 February 2023
Resolved 19 February 2023
Resolution: ships crew found a loose conncection for both sets of lights. they reattached connection point and the lights stopped flickering
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2022
Resolved
All electrical appliances shall be so constructed and installed as not to cause injury when handled or touched in the normal manner. USCG PSCO observed and overhead lighting fixture on Deck 2, adjacent to Cabin 1276 was dripping water onto the deck. The fixture was full of water.
Action required: 10 - Deficiency Rectified
Resolved 27 August 2022
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 27 August 2022
Resolved
The illumination provided shall be such that the approach to the means of escape can be readily seen. USCG PSCO observed the low location lighting in FWD stairway, Deck 11 in the spa/gym was flickering, dim, and inoperable.
Action required: 10 - Deficiency Rectified
Resolved 27 August 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 September 2021
Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. USCG Port State Control Officers discovered several overhead lighting fixtures located on Deck 6, in the midship STBD, room service galley, had accumulated water inside of the lighting fixture. SOLAS II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2021
Resolved 21 September 2021
Resolution: Insulation to chiller piper inspected and replaced. Light fixtures corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 September 2021
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. Provision shall be made for marking each life raft with the name and port of registry of the ship to which it is fitted. USCG Port State Control Officers discovered that all of the life rafts onboard had been recently replaced in dry-dock and that each loife raft was missing the vessel specific information documnet on the marking sheet attached to the life raft. SOLAS III/34
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 12 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 September 2021
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboat #8 was utilized during the lowering of lifeboats to tender crews to each lifeboat for testing. Lifeboat #8 suffered an engine cooling casualty to the port engine during the lifeboat drills. SOLAS III/34
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 September 2021