650-3 is a 2007 tank barge. The Coast Guard has recorded 57 inspections since 2006, most recently in June 2026, along with 32 deficiencies and 15 casualty investigations between 2010 and 2025.

Records from 2006 to 2026. Most recent: inspection, 10 June 2026.

Built
2007
Last inspected
10 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

877595
Flag
UNITED STATES
Maury page id
psix-877595

Inspections, by type

…with no type recorded16
Years with a record 20 calendar years (2006–2026)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)559.8 ft × 74.0 ft × 40.1 ft
Registered tonnagegross 11,147 / net 11,147
ITC dimensions (L × B × D)559.8 ft × 74.0 ft × 40.1 ft
ITC tonnagegross 13,462 / net 8,791
BuilderV.T. HALTER MARINE · PASCAGOULA, MS, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 July 2026 · expires 31 August 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11147 - Regulatory (Subpart C or D), Gross Ton
13462 - Convention (Subpart B), Gross Ton
11147 - Regulatory (Subpart C or D), Net Ton
8791 - Convention (Subpart B), Net Ton
27023 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

RESOLVE Towing Vessel · MISLE 870678 · 31 October 2025 · activity 8261445RESOLVE Towing Vessel · MISLE 870678 · 13 September 2025 · activity 8235053RESOLVE Towing Vessel · MISLE 870678 · 7 September 2025 · activity 8228752RESOLVE Towing Vessel · MISLE 870678 · 31 August 2025 · activity 8225963RESOLVE Towing Vessel · MISLE 870678 · 20 August 2025 · activity 8217563RESOLVE Towing Vessel · MISLE 870678 · 16 May 2025 · activity 8151869RESOLVE Towing Vessel · MISLE 870678 · 6 December 2024 · activity 8045877RESOLVE Towing Vessel · MISLE 870678 · 5 July 2024 · activity 7961286RESOLVE Towing Vessel · MISLE 870678 · 8 April 2020 · activity 6951267JEFFREY MCALLISTER Towing Vessel · MISLE 1407738 · 8 April 2020 · activity 6951267CAPT. JIM MCALLISTER Towing Vessel · MISLE 1528587 · 8 April 2020 · activity 6951267RESOLVE Towing Vessel · MISLE 870678 · 21 March 2014 · activity 4821212RESOLVE Towing Vessel · MISLE 870678 · 27 October 2012 · activity 4479294RESOLVE Towing Vessel · MISLE 870678 · 22 September 2012 · activity 4449184RESOLVE Towing Vessel · MISLE 870678 · 4 August 2012 · activity 4406073BOCA DEL DRAGO Towing Vessel · MISLE 94612 · 25 October 2010 · activity 3906733RESOLVE Towing Vessel · MISLE 870678 · 25 October 2010 · activity 3906733RESOLVE Towing Vessel · MISLE 870678 · 19 April 2010 · activity 3720254

Inspection history · 57

10 June 2026 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8397693
31 October 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8261445
13 September 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8235053
7 September 2025 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8228752
31 August 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8225963
20 August 2025 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8217563
16 May 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8151869
14 May 2025 Administrative Inspection · Examination of Repairs · Cargo Tank Internal · COI Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8135796
7 April 2025 Ballast Water Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8110393
9 February 2025 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8076989
18 December 2024 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8048877
6 December 2024 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8045877
2 December 2024 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8041943
16 October 2024 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8024761
19 September 2024 MARPOL Annex II Examination · Administrative Inspection · Deficiency Check · MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8000721
5 July 2024 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7961286
2 February 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7860780
26 September 2023 MARPOL Annex I Examination · Administrative Inspection · Annual Inspection · MARPOL Annex II Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7798886
11 July 2022 Drydock Exam · Administrative Inspection · COI Inspection · MARPOL Annex II Examination · Internal Structural Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7503672
30 July 2021 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7272758
2 October 2020 Periodic Inspection · Examination of Repairs · Administrative Inspection · MARPOL Annex II Examination · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7070349
9 April 2020 Internal Structural Exam · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6937497
8 April 2020 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6951267
9 October 2019 Annual Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6831129
4 October 2018 MARPOL Annex I Examination · Annual Inspection · MTSA Verification · MARPOL Annex II Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6554571
19 September 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6269941
10 July 2017 Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6204469
28 November 2016 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6049188
1 November 2016 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6033325
30 November 2015 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5772127
9 November 2015 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5758967
20 April 2015 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5107036
23 March 2015 Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5093951
20 October 2014 Periodic Inspection · MTSA Verification · MARPOL Annex II Examination · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5008737
21 March 2014 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4821212
21 November 2013 Annual Inspection · MTSA Verification · MARPOL Annex I Examination · MARPOL Annex II Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4756082
27 October 2012 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4479294
19 October 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4467617
22 September 2012 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4449184
5 September 2012 Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4433082
17 August 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4413991
5 August 2012 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4401659
4 August 2012 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4406073
14 October 2011 MARPOL Annex II Examination · Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4190608
30 November 2010 Periodic Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3900972
26 October 2010 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3877806
25 October 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3906733
22 September 2010 Administrative Inspection · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3853320
8 July 2010 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3789870
14 May 2010 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3742321
19 April 2010 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3720254
19 April 2010 Administrative Inspection · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3720480
9 April 2010 Administrative Inspection · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3730759
9 January 2009 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3391531
4 December 2008 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3376110
18 March 2008 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3166781
17 January 2006 Internal Structural Exam · MTSA Verification · Drydock Exam · Underwater Inspection in lieu of Drydock · Cargo Tank Internal · Ballast Water Examination · Initial Construction-Excluding Oversight · Hull Examination · Construction Oversight · MARPOL Annex II Examination · Plan Review (Other than "T") · Initial Certification · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2914325

Deficiency record · 32

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2025 Resolved
Electrical equipment should not be installed in hazardous locations unless essential for operational purposes. When installed in these locations, special precautions should be taken to ensure that the electrical equipment is not a source of ignition. MI observed missing cable gland on IG pressure switch outside IGG room. Repair to the satisfaction of the MI. 46 CFR 111.105-3(a) 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2025
Resolved 23 July 2025
Resolution: Completed final walk through on Vessel with all cabling, Junction Boxes, Packing Glands, Chaffing Protection, and Hardware in full working condition.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 July 2025 Resolved
A carbon dioxide or clean agent system as described in 46 CFR subpart 95.16 or a water spray system must be installed in all lamp and paint lockers, oil rooms, and similar spaces. MI observed no Fire Extinguishing system in or near Cargo Sample Locker at Port Manifold Deck. Provide Fire Extinguishing system for sampling locker. 46 CFR 34.05-5(a)(3) 701c Vessel given 7 days to provide Fire Extinguishing system to Cargo Sampling Locker.
Action required: 705 - Other - as specified
Due 30 July 2025
Resolved 24 July 2025
Resolution: Recevied photos of Fixed Fire Fighting system installed to the cargo sample locker.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 22 July 2025 Resolved
Piping systems used where the fluid temperature exceeds 150 °F must be suitably insulated as necessary to preclude injury to personnel. MI observed sections of the Thermal Fluid Heater piping not covered in insulation. Install insulation for crew protection to the satisfaction of the MI. 46 CFR 56.50 (k) 16c Vessel given 14 days to complete insulation on thermal piping. Missing small section in aft of the vessel piping.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2025
Resolved 24 July 2025
Resolution: Recevied photos of insulation installed on missing sections of Thermal Fluid Piping.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 22 July 2025 Resolved
The master shall ensure that the following chemical protective clothing constructed of materials resistant to permeation by the cargo being handled is worn by all personnel engaged in an operation. MI Observed no Chemical Resistant protection for handling of cargoes regulated in CFR 153. Provide Chemical protective clothing to the satisfaction of the MI. 46 CFR 153.933 (a) 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2025
Resolved 23 July 2025
Resolution: Provided Basic Level of chemical resistant PPE.
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 22 July 2025 Resolved
No cargo tank hatches, ullage holes, or Butterworth plates shall be opened or shall remain open without flame screens, except under the supervision of the senior members of the crew on duty, unless the tank opened is gas free. Marine inspector observed Butterworth plate unbolted and opened. 46 CFR 35.30-10 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2025
Resolved 23 July 2025
Resolution: Cargo Hatch properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2025 Resolved
Electrical equipment should not be installed in hazardous locations unless essential for operational purposes. When installed in these locations, special precautions should be taken to ensure that the electrical equipment is not a source of ignition. Marine inspector observed multiple electrical wiring hazards to include detracted outer protective over that exposed the inner weave of the cable. This condition was observed at: # 1 forward power box, #4 P power box, #6 P power box. Repair to the satisfaction of the Marine Inspector. 46 CFR 111.105-3(a) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 23 July 2025
Resolution: Completed final walk through on Vessel with all cabling, Junction Boxes, Packing Glands, Chaffing Protection, and Hardware in full working condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2025 Resolved
Electrical equipment should not be installed in hazardous locations unless essential for operational purposes. When installed in these locations, special precautions should be taken to ensure that the electrical equipment is not a source of ignition. Marine inspector observed 03 explosive boxes painted to include painted over explosion box seals in location S forward-center & S forward windlass. Repair to the satisfaction of the Marine Inspector. 46 CFR 111.105-3(a) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 23 July 2025
Resolution: Completed final walk through on Vessel with all cabling, Junction Boxes, Packing Glands, Chaffing Protection, and Hardware in full working condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2025 Resolved
Electrical equipment should not be installed in hazardous locations unless essential for operational purposes. When installed in these locations, special precautions should be taken to ensure that the electrical equipment is not a source of ignition. Marine inspector observed missing chaffing gear on forward control gear, P & S side cable runs above fuel tanks, #7 S cargo level indicator, #4 P ballast level indicator, S stern winch wire, #6 S ballast level indicator, forward breast controller, #4 cargo tank level indicator. Repair to the satisfaction of the Marine Inspector. 46 CFR 111.105-3(a) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 23 July 2025
Resolution: Completed final walk through on Vessel with all cabling, Junction Boxes, Packing Glands, Chaffing Protection, and Hardware in full working condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2025 Resolved
Each outlet or junction box must be securely attached to its mounting and be affixed so as to maintain its designated degree of protection. Marine inspector observed ballast water overboard discharge junction box improperly mounted. Repair to the satisfaction of the Marine Inspector. 46 CFR 111.81-1(e) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 23 July 2025
Resolution: Completed final walk through on Vessel with all cabling, Junction Boxes, Packing Glands, Chaffing Protection, and Hardware in full working condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2025 Resolved
Batteries must be constructed to take into account the environmental conditions of a marine installation, including temperature, vibration, and shock. Marine inspector observed wire nuts installed on S forward battery box. Repair to the satisfaction of the Marine Inspector. 46 CFR 111.15-2(d) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 23 July 2025
Resolution: Completed final walk through on Vessel with all cabling, Junction Boxes, Packing Glands, Chaffing Protection, and Hardware in full working condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2025 Resolved
Vessels in ocean, coastwise, or Great Lakes service, except unmanned barges, must be fitted with anchors. chains, and hawsers in general agreement with the Standards established by the American Bureau of Shipping, see 46 CFR part 90, subpart 90.35. Marine inspector observed wasted securing points on the S forward anchor windlass control. Repair to the satisfaction of the Marine Inspector. 46 CFR 96.07-5(a) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 23 July 2025
Resolution: Completed final walk through on Vessel with all cabling, Junction Boxes, Packing Glands, Chaffing Protection, and Hardware in full working condition.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2025 Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Lights for amidship lifebuoys were not attached to the lifebuoy's (Port and Starboard). Repair to the satisfaction of the Marine Inspector. 46 CFR 199.190 (a) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 23 July 2025
Resolution: Lights properly connected to lifebuoy's.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 22 July 2025 Resolved
When transferring cargo while fast to a dock or at anchor in port, the master shall ensure that the tank ship displays a warning sign at the gangway facing the shore so that it may be seen from the shore and another warning sign facing outboard toward the water so that it may be seen from the water. Each warning sign must have the following legends: Warning. Dangerous Cargo. No Visitors. No Smoking. No Open Lights. Marine Inspector observed no warning signs posted on the Port Side Manifold's. Repair to the satisfaction of the Marine Inspector. 46 CFR 153.955 (a)(b) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 23 July 2025
Resolution: Warning Notice signs properly posted on the Port Manifold side.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2025 Resolved
Each life jacket must have a whistle firmly secured by a cord to the life jacket. Marine Inspector observed whistle line attached break due to deteriorating line. Repair to the satisfaction of the Marine Inspector. 46 CFR 199.70 (b)(4)(ii) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 23 July 2025
Resolution: Whistle properly attached to PFD.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2025 Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port required to be marked on the stern of the vessel. Marine Inspector observed the Port Aft and Port amidships lifebuoy's without proper name of vessel. Repair to the satisfaction of the Marine Inspector. 46 CFR 199.70 (a)(2) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 23 July 2025
Resolution: Lifebuoy's displaying proper vessel name.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 February 2025 Resolved
When inspecting oil-burning vessels, either internal-combustion type or steam-driven type, the marine inspector shall examine the tank tops and bilges in the fireroom and engineroom to see that there is no accumulation of oil which might create a fire hazard. After examining the #2 (stbd) service generator, MI noticed bucket catching oil and a significant amount of oil accumulation surrounding the generator. Secure the source of oil leak and clean-up oil accumulation prior to cargo operations. 46 CFR 31.10-50(a)
Action required: 705 - Other - as specified
Due 10 February 2025
Resolved 10 February 2025
Resolution: All oil accumulation removed and leak secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2024 Resolved
Inerted means the oxygen content of the vapor space in a cargo tank is reduced in accordance with the inert gas requirements of 46 CFR 32.53. The master shall ensure that the inert gas system is operated as necessary to maintain an inert atmosphere in the cargo tanks. One IG combustion chamber reported inoperable; prior to discharge of cargo, IG combustion chamber to be repaired to satisfaction of Coast Guard Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 December 2024
Resolution: Recieved ABS Class report attesting to satisfactory repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2024 Resolved
The installation of all electrical engineering systems must meet the requirements of Subchapter J. Class I, Division 1 locations on the weather deck may have only approved intrinsically safe or explosion proof equipment. Numerous electrical cables within the hazardous zone were found with the outer sheath deteriorated. Chief Engineer attested that these cables still have a satisfactory inner sheathing. Since the electrical cables do not meet the manufacturers specifications, the vessel shall complete temporary repairs of all deteriorated electrical cables to the satisfaction of the attending Coast Guard Marine Inspector. Permanent repairs will be completed at next shipyard but no later than 31MAY2025.
Action required: 705 - Other - as specified
Due 31 May 2025
Resolved 22 July 2025
Resolution: Electrical wiring was corrected during drydock by replacing.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 19 September 2024 Resolved
Samples which have to be kept on board shall be stowed in a designated space situated in the cargo area. The stowage space shall be cell-divided in order to avoid shifting at sea and equipped with adequate ventilation. The cargo samples were not cell-divided. Provide adequate division of cargo samples to the satisfaction of the attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2024
Resolved 30 September 2024
Resolution: Appropriate protective equipment placed in storage cabinet.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 September 2024 Resolved
All lifesaving appliances and arrangements on tank vessels must be in accordance with Subchapter W. Lifebuoys, including those with attached lights, must be so distributed as to be readily available on each side of the vessel. Each cargo vessel must carry the number of lifebuoys prescribed in Table 199.271. For vessels 492 feet in length but less than 656 feet in length, 12 ring lie buoys are required, however per Enclosure 2 of NVIC 02-81 CH 2, the vessel may be outfitted with half this number for a total of 6. Vessel currently has 3 ring lifebuoys on board with only one having an attached light. Install three more lifebuoys, to include another with an attached light, for a grand total of 6 lifebuoys with 2 attached lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2024
Resolved 30 September 2024
Resolution: Ring buoys and appropriate attachments installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2021 Resolved
Each alternating-current ship's service switchboard must have a voltage regulator and voltage regulator functional cut-out switch. Switchboard on starboard side of cargo control space on barge is missing manual voltage regulator. Prove proper arrangement of voltage regulator on switchboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2021
Resolved 2 August 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2021 Resolved
The following location in the weather is a Class I, Division I (Zone I) location and may have only approved intrinsically safe, explosionproof, or purged and pressurized equipment: within 10 feet of a cargo tank ullage opening. Nav light batteries on forward part of the deck are approximately 06 feet from ullage openings. Demonstrate proper arrangement of batteries 10 feet from ullage openings and not in a hazardous location.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2021
Resolved 2 August 2021
01 - Certificates & Documentation › 013 - Documents › Shipboard marine pollution emergency plan for NLS
Issued 9 April 2020 Resolved
Vessel response plan required for unmanned tank barges carrying oil as primary cargo. Procedures in the order of priority for the crew to mitigate or prevent any discharge or a substantial threat of such a discharge in the event of the following casualties or emergencies: grounding and stranding, explosion or fire, hull failure, excessive list, equipment failure. Master and crew did not follow vessel's VRP or activate it upon notice of potential grounding. Master failed to do the following IAW the VRP and ISM: sound alarms, muster crew, take soundings, or call securite on the radio. Additionally, Master did not implement plans IAW company procedures as per document no. ATB-VOM-11. Due to deficient condition, COTP will require ISM audit to be conducted covering inadequacies within the next 30 days. Once completed, forward findings to the email listed below.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2020
Resolved 30 April 2020
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 November 2015 Resolved
Bulkhead / structure multicable transits A-60 penetrations. Roxtec wedges and stayplates wasted.
Due 10 December 2015
Resolved 30 November 2015
Resolution: Wedges and stayplates replaced.
Construction/Loadline › Hull › Hull Plating
Issued 5 August 2012 Resolved
Prior to loading cargo, proceed to Malin Marine dock #28 to make permanent repairs to a 6" x 2" fracture in the #7 STBD ballast tank at approx the 11' draft mark, to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 August 2012
Resolution: Satisfactory repairs made to fracture. Issued 835 clearing deficiency.
Construction/Loadline › Hull › Hull Plating
Issued 26 October 2010 Resolved
Vessel has a 2' x 3' x 2" inset to the #3 stbd wing void. Survey within 30 days.
Action required: 705 - Other - as specified
Due 25 November 2010
Resolved 5 September 2012
Resolution: Credit DDX/ISE performed. No callouts made.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 7 May 2010 Resolved
Properly install the VCS flange stud per 46 CFR 39.20-1. Studs must be permenently installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2010
Resolved 7 May 2010
Resolution: Received notification that satisfys the requirement.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 7 May 2010 Resolved
Vessel is prohibited from cargo operation (Loading or Unloading) until the port generator is re-installed and tested to the satisfaction of attending Marine Inspector and class (ABS).
Action required: 705 - Other - as specified
Resolved 15 May 2010
Resolution: Censet properly installed and satisfactorily tested by ABS Surveyor [name withheld]
Electrical › Electric Generation Source (service) › Generator
Issued 7 May 2010 Resolved
Port service diesel generator was damaged due a fire. Vessel O/O was granted permission to make repairs @ this port, however generator could not repair by schedule departure. Vessel is permitted to depart port , proceed to lay berth (Texas City, TX) to re-install generator and test to the sat. of USCG and Class prior to cargo operations.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 15 May 2010
Resolution: ABS Surveyor attended the vessel and verified proper installation and operation of the Genset.
Deck/Cargo › Cargo Stowage › General
Issued 4 May 2010 Resolved
During the transit to the lay berth, Texas City, Tx, the vessel must remain in an gas free/inerted stated.
Due 13 May 2010
Resolved 15 May 2010
Resolution: Genset installed and tested. Vessel cleared for cargo operations.
Electrical › Electric Generation Source (service) › Generator
Issued 19 April 2010 Resolved
Port service generator was damaged by fire which originated in generator housing. Prime mover was not damaged. O/O to repair genset to Class.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 May 2010
Resolved 7 May 2010
Resolution: Cleared.
Electrical › Electric Generation Source (service) › Generator
Issued 19 April 2010 Resolved
Port service generator was damaged by fire which originated in generator housing. Prime mover was not damaged. O/O to prove proper operation in presence of an attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 19 May 2010
Resolved 7 May 2010
Resolution: DF being cleared and another issued pertaining to the generator.

Casualty record · 15

19 April 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3720254
4 August 2012Routine · role: Involved in a Marine Casualty · activity 4406073
22 September 2012Routine · role: Involved in a Marine Casualty · activity 4449184
27 October 2012Routine · role: Involved in a Marine Investigation (non-casualty) · activity 4479294
17 January 2013Routine · role: Source Vessel for Cargo Transfer · activity 4520382
21 March 2014Routine · role: Transiting Vicinity of Primary Subject · activity 4821212
8 April 2020Routine · role: Involved in a Marine Casualty · activity 6951267
5 July 2024Routine · role: Involved in a Marine Investigation (non-casualty) · activity 7961286
6 December 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8045877
16 May 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 8151869
20 August 2025Routine · role: Involved in a Marine Casualty · activity 8217563
31 August 2025Routine · role: Involved in a Marine Investigation (non-casualty) · activity 8225963
7 September 2025Routine · role: Involved in a Marine Casualty · activity 8228752
13 September 2025Routine · role: Involved in a Marine Investigation (non-casualty) · activity 8235053
31 October 2025Routine · role: Subject to Marine Inspection · activity 8261445
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.