Records from 2007 to 2025. Most recent: inspection, 27 August 2025.
Documentation record
Registered dimensions (L × B × D)92.6 ft × 36.0 ft × 17.3 ft
Registered tonnagegross 269 / net 183
ITC dimensions (L × B × D)92.6 ft × 36.0 ft × 17.3 ft
ITC tonnagegross 398 / net 119
BuilderORANGE SHIPBUILDING · ORANGE, TX, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN JUAN, PR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it119 - Convention (Subpart B), Net Ton
183 - Regulatory (Subpart C or D), Net Ton
359 - Dead Weight, Ton
398 - Convention (Subpart B), Gross Ton
269 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 35
27 August 2025
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8219682
22 July 2025
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8192245
27 May 2025
Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8145196
30 April 2025
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8127369
17 April 2025
Administrative Inspection · COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8130910
6 March 2025
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8089633
10 June 2024
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7931618
3 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7889514
13 July 2023
Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7745789
15 February 2023
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7637396
6 September 2022
Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7552000
2 September 2022
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7549686
17 August 2022
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7604345
9 June 2021
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7221581
18 March 2021
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7158593
3 February 2021
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7135392
26 August 2020
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7043188
13 August 2020
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7032227
22 July 2020
Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7014397
20 May 2020
MTSA Verification · Administrative Inspection · Initial Certification · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6948163
2 August 2018
Initial Certification · DAPI Audit · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6496763
31 July 2018
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6496426
9 October 2017
Damage Survey · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6287152
20 September 2017
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6287125
26 October 2015
Industry Initiated Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5753761
23 February 2015
MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5073500
6 June 2012
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4335542
4 May 2012
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4335632
6 March 2012
Deficiency Check · Industry Initiated Exam · MTSA Verification
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4258220
15 July 2010
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3802500
9 June 2010
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3762199
22 February 2010
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3683644
15 December 2009
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3651022
13 January 2009
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3394041
21 June 2007
MTSA Verification · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2969370
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 May 2025
Resolved
Where practicable and except as provided in § 144.515, each space where crew may be quartered or normally employed must have at least two means of escape. Re- install escape hatch on steering gear room. 46CFR144.500
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2025
Resolved 27 May 2025
Resolution: Crew does not normlly man space. Escape not required. See documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 September 2022
Resolved
Machinery and electrical systems bust be designed and maintained to provide safe operation of the towing vessel and safety of person on board under normal and emergency conditions. The vessel's port generator's battery was in a degraded state which prevented the generator from starting. Replace battery in kind.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 September 2022
Resolved 6 September 2022
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 September 2022
Resolved
Each vessel must have either a self-priming, power-driven, a fire main with hoses and nozzles. Vessel's installed fire pump malfunctioned during testing. A portable self-priming pump was brought on board to temporary satisfy this requirement. Demonstrate functionality of fire pump documented on COI to the satisfaction of a CG Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2022
Resolved 8 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 6 September 2022
Resolved
Each towing vessel operating in oceans and coast-wise service must have a line throwing appliance approved under approval serious 46CFR160.040 which states that an approved appliance with a total of 4 charges. Provide 03 additional appliances or charges to satisfy this requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2022
Resolved 13 September 2022
Resolution: Verified the vessel had 4 line-throwing appliances on-board.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 September 2022
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. VSL must undergo an Annual inspection before it can operate. 46CFR137.200
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2022
Resolution: Team from SEC San Juan attended VSL and completed the annual inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2021
Resolved
Each space where crew may be quartered or normally employed must have at least two means of escape. The machinery space emergency escape does not provide for adequate means for the crew to efficiently exit the space. The current installation would require a crew member to climb 53 inches to access the first rung, does not have enough rungs to safely exit through the escape trunk, and is next to the starboard main engine's turbo which causes a hazard to the crew.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 18 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 February 2021
Resolved
All seals and gaskets must be properly maintained to prevent leaks. Port side main diesel engine was actively leaking lubricating oil from the cylinder block gasket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 18 March 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 February 2021
Resolved
A towing light should show and unbroken light over an arc of the horizon of a 135 degrees. The current installation of the towing lights precludes the light from being visible over the required degrees.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 18 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 May 2020
Resolved
Vessel must be equipped with a semi-portable 160-B fire
extinguisher. Vessel does not have a semi-portable 160-B
fire extinguisher.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 22 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 May 2020
Resolved
Pressure vessels must be equipped with a pressure gauge
and relief valve. Pressure vessels were found to be
missing relief valves and gauges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 21 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2020
Resolved
Pressure vessels must indicate MAWP and have it visible
to crew. Data plates are missing on all pressure
vessels.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 21 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 20 May 2020
Resolved
Machinery must be designed and maintained to provide for
safe operation of the towing vessel. Marine Inspector
observed evidence of exhaust leak in lagging that was
discolored.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 21 August 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 May 2020
Resolved
Electrical systems must be designed and maintained to
provide for safe operation of the towing vessel. Battery
installation was not secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 21 August 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 May 2020
Resolved
Electrical systems must be designed and maintained to
provide for safe operation of the towing vessel. Marine
inspector observed dead end cable on the STBD side
operating cabinet.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 21 August 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 May 2020
Resolved
Vessel must have a valid FCC Safety Radiotelephony
Certificate. Single side band radio was not surveyed
according to Certificate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 22 July 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 May 2020
Resolved
Vessel security plan must describe in detail how the
requirements of 33 CFR part 104 will be met. Vessel's
security plan needs to be updated to reflect current
security procedures.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 21 August 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 May 2020
Resolved
Towing vessel must be equipped with appropriate first
aid kit. Several medicines are expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 21 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 May 2020
Resolved
A vessel must carry appropriate day shapes. The vessel
was found to be missing one diamond.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 21 August 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 May 2020
Resolved
Security drills must be conducted within a week from
whenever the percentage of new personnel exceeds 25%.
Vessel does not conduct drills when there is more than a
25% change in crew.
Action required: 10 - Deficiency Rectified
Resolved 4 June 2020
Resolution: Vessel rep and master reminded to record entries and conduct training in the future.