Inspection history · 33
6 March 2026
Annual Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8321012
17 March 2025
Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8095130
5 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8088986
26 February 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7871042
21 February 2024
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7877705
9 January 2024
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7846478
13 November 2023
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7823890
15 December 2022
Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7607654
8 September 2022
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7554468
15 July 2022
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7511068
17 February 2021
Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7147923
3 February 2021
In-Service Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7135369
18 December 2018
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6599800
18 September 2018
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6543847
31 July 2018
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6496456
10 July 2015
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5189994
12 May 2015
MTSA Verification · DAPI Audit · Industry Initiated Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5124445
19 April 2013
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4572371
4 May 2012
Industry Initiated Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4257446
7 March 2012
Administration
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4263427
15 July 2010
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3802549
9 June 2010
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3762199
22 February 2010
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3683644
15 December 2009
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3651022
13 January 2009
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3394028
13 August 2008
MTSA Verification · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3298011
20 November 2006
MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2825277
7 April 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2618953
24 April 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 117916
3 April 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 101929
25 September 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 155120
12 September 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 166626
12 September 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 218749
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 March 2026
Resolved
Essential systems or equipment must be regularly tested and examined. Each towing vessel must preform tests in table 143.245(b)... Pressure vessel relief valaves, vessel must recertify pressure relief valves. 46CFR 143.245 - 16(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2026
Resolution: Vessel company submitted documentary evidence to clear the outstanding deficiencies.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 March 2026
Resolved
The master must ensure lifesaving equipment is properly maintained and ready for use at all times. Spotlight on pilothouse is seized in one position for mob or etc. replace/repair in-kind. 46CFR 140.725(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2026
Resolution: Vessel company submitted documentary evidence to clear the outstanding deficiencies.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 6 March 2026
Resolved
Each accommodation space on a vessel must be ventilated in a manner suitable for the purpose of the space. Galley exhaust fan was found inoperable, head exhaust fan was found inoperable. Repair/Replace in-kind. to include galley grease filters(one panel missing). 46 CFR 144.600
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2026
Resolution: Vessel company submitted documentary evidence to clear the outstanding deficiencies.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 March 2026
Resolved
All suction valves necessary for the operation must be kept in open position. Suction valves on fire pump were found leaking water in the open position. replace valve/packing. 46 CFR 142.325(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2026
Resolution: Vessel company submitted documentary evidence to clear the outstanding deficiencies.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 March 2025
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Remove oily bilge water from bilge. 46CFR142.220 (a)
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2025
Resolved 17 March 2025
Resolution: This office has received photo and document evidence showing the correction of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Replace 03 outlets in galley countertop with GFCI outlets. 46CFR143.400(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 17 March 2025
Resolution: Outlets removed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 March 2025
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Repair handrail aft of Port engine. 46CFR144.800 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 17 March 2025
Resolution: This office has received photo and document evidence showing the correction of deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 March 2025
Resolved
Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings. Provide pressure cuff. 46CFR140.435
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 17 March 2025
Resolution: This office has received photo and document evidence showing the correction of deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 March 2025
Resolved
Each towing vessel must be equipped with sound signals. Repair vessel whistle. 46 CFR140.720
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 17 March 2025
Resolution: This office has received photo and document evidence showing the correction of deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 March 2025
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Provide log book showing test performed IAW with 46CFR143.245.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 6 March 2026
Resolution: Verified record keeping onboard with logbook.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 March 2025
Resolved
Survival craft and stowage locations must be marked in accordance with the requirements of §§ 199.176 and 199.178 of this chapter. [name withheld] raft IAW with this requirement. 46CFR141.315
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 17 March 2025
Resolution: This office has received photo and document evidence showing the correction of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 10 March 2025
Resolved
. Each escape hatch and emergency exit used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”.
Install labels on both sides of all emergency exits. 46CFR144.160 (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 17 March 2025
Resolution: This office has received photo and document evidence showing the correction of deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 March 2025
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. Create log IAW this requirement. 46CFR140.635.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 17 March 2025
Resolution: This office has received photo and document evidence showing the correction of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 March 2025
Resolved
Sufficient lighting suitable for the marine environment must be provided within crew working and living areas. Lightbulb was missing in the socket inside the fire locker cabinet. Must replace in-kind. 46CFR143.410 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 17 March 2025
Resolution: This office has received photo and document evidence showing the correction of deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 March 2025
Resolved
Lifejackets must be readily accessible. Lifejackets in accommodation spaces must be stored readily available without obstruction. 46CFR141.340
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 17 March 2025
Resolution: This office has received photo and document evidence showing the correction of deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 6 March 2024
Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months. Engine room fiddley exhaust fan missing metal dampener which will allow CO2 system gasses to escape the engine room reducing systems effectiveness. Install metal dampener that effectively seals opening of the exhaust fan.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 April 2024
Resolved 19 March 2024
Resolution: Attending MI received witnessed the installation of engine room fiddley fan damper Def #1, tested sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 March 2024
Resolved
The owner, managing operator, or master of a towing vessel must ensure that the vessel's fire suppression equipment complies with the applicable requirements of parts 141 and 142 of this sub-chapter and is in good working order. Install operating instructions for the installed Fire suppression systems manual operation opening in the port side of the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 19 March 2024
Resolution: Attending MI witnessed the installation of operating instructions.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 6 March 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Install machinery guard over the aft winch motor crankshaft vibration dampener.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 19 March 2024
Resolution: Witnessed the installation of the machinery guard.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 March 2024
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress. Install emergency light that focuses on the aft engine room emergency escape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 12 March 2024
Resolution: Attending MI received photo evidence of the installation of emergency lighting. Photo uploaded to the documents tab.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 December 2022
Resolved
All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended back flooding through bilge piping. Provide evidence of installed check valves.
46 CFR 143.275
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 December 2022
Resolved 20 December 2022
Resolution: VSL rep installed 02 check valves on 02 engine room bilge suction points, all SAT.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 December 2022
Resolved
Cargo ships of 300 gross tonnage and upwards are required long range identification and tracking. No LRIT was provided on board. Vessel is not permitted to operate internationally until an LRIT is installed.
74 SOLAS(20) V/19-1
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 January 2023
Resolved 11 December 2023
Resolution: Attending MI received email confirmation from service provider that the LRIT was active.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 3 February 2021
Resolved
Marine Inspector observed several ballast/void tank covers in machinery space missing nuts through installed bolts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2021
Resolved 2 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 February 2021
Resolved
Marine Inspector observed a Personal marker light ona Type I PFD located in a stateroom that expired in 2017. Also, vessel name on PFD was incorrect.
Hydrostatic release for installed EPIRB depicted as expired July, 2020.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2021
Resolved 2 March 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2021
Resolved
Marine Inspector observed various electrical hazards throughout vessel. Properly secure electrical wires as designed on strboard steering pump motor. Electrical control box on starboard side of machinery space unsecured. Various electrical hazards in "gyro" closet, several dead-end wires, plastic wire ties holding wiring/cabeling together. Electrical wire in stateroom pulled from overhead and being used to hang a privacy sheet. Various electrical light fixtures missing safety cvoers for bulbs. Several emergency lights thoughout vessel inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2021
Resolved 2 March 2023