MAURY USCG vessel records
← All vessels

SEA CREST

Built
1982
Last inspected
16 October 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 16 October 2025
…with no type recorded59
Operational controls None recorded without a removal date
Years with a record 42 calendar years (1984–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-54593

Documentation record

Registered dimensions (L × B × D)258.6 ft × 70.0 ft × 18.0 ft
Registered tonnagegross 2,815 / net 1,672
ITC dimensions (L × B × D)258.6 ft × 70.0 ft × 18.0 ft
ITC tonnagegross 2,815 / net 1,672
BuilderZIDELL EXPLORATIONS INC · PORTLAND, OR, UNITED STATES · built 1982
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, DE
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 16 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1672 - Convention (Subpart B), Net Ton
6450 - Dead Weight, Net Ton
2815 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 139 inspections, each with its date, unit and type; 54 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 9 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 9

Inspection history · 139

16 October 2025 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8257652
12 September 2025 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8236377
9 October 2024 MARPOL Annex II Examination · Internal Structural Exam · MTSA Verification · MARPOL Annex I Examination · Periodic Inspection · MARPOL Annex IV Survey · Permit to Proceed · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8003997
25 September 2023 Annual Inspection · MARPOL Annex II Examination · Deficiency Check · MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7781308
14 June 2022 Cargo Tank Internal · COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7473779
22 November 2021 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7356079
4 October 2021 Administrative Inspection · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7326567
27 August 2021 Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7298294
23 November 2020 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7100632
16 October 2020 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7068783
8 November 2019 Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6851988
10 October 2019 MTSA Verification · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · MARPOL Annex II Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6832419
6 March 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6638581
21 September 2018 Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6545613
29 June 2017 MARPOL Annex I Examination · Hull Examination · Deficiency Check · COI Inspection · MTSA Verification · MARPOL Annex VI Survey · Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · VRP Drill
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6190413
16 November 2016 MARPOL Annex I Examination · Administrative Inspection · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6042262
26 March 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6028456
24 March 2016 Examination of Repairs · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5839897
24 March 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5840075
24 September 2015 MARPOL Annex VI Survey · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5728833
4 December 2014 Annual Inspection · Internal Structural Exam · MARPOL Annex I Examination · MTSA Verification · MARPOL Annex VI Survey · MARPOL Annex II Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5032730
20 October 2014 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5008816
6 February 2014 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4791879
7 November 2013 Annual Inspection · MTSA Verification
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4748980
8 July 2013 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4646818
17 August 2012 MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex I Examination · COI Inspection · MARPOL Annex II Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4410813
9 July 2012 Internal Structural Exam · Drydock Exam · Administrative Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4373039
10 November 2011 Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · MARPOL Annex II Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4182554
22 June 2010 MARPOL Annex I Examination · Hull Examination · MARPOL Annex II Examination · Periodic Inspection · MARPOL Annex VI Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3773741
16 January 2010 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3666022
7 January 2010 Administrative Inspection · MARPOL Annex II Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3660379
14 March 2009 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3434328
8 October 2008 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3342341
14 August 2007 COI Inspection · MARPOL Annex II Examination · Hull Examination · Deficiency Check · MTSA Verification · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3027641
19 July 2007 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3000548
10 October 2006 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2797823
15 May 2006 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2649677
11 October 2005 MTSA Verification · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2512146
5 May 2005 MARPOL Annex II Examination · MARPOL Annex I Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2349818
22 February 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2296994
4 February 2005 Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2286814
28 October 2004 MARPOL Annex II Examination · MARPOL Annex I Examination · Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2230247
29 September 2004 Annual Inspection · MTSA Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2208779
21 June 2004 Internal Structural Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2105641
30 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1998652
24 October 2003 Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1935519
21 October 2003 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1933179
6 December 2002 Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1715294
16 July 2002 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1646987
16 July 2002 Cargo Tank Internal · Internal Structural Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1647149
25 October 2001 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 772005
7 October 2001 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1450678
1 July 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 679277
21 June 2000 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 819094
8 June 2000 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1436391
21 April 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 199747
21 April 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 450913
7 October 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 886451
30 June 1999 Re-Inspection · Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1433506
10 June 1998 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 791638
2 December 1997 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 775637
26 June 1997 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1438606
2 July 1996 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1392500
26 June 1996 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1242055
9 June 1995 Re-Inspection · Examination of Repairs · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1430055
9 August 1994 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1170958
7 July 1994 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1363033
28 June 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 672971
30 May 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 137032
13 January 1994 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 850494
16 December 1993 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1159832
12 October 1993 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 829752
19 August 1993 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 845235
22 July 1993 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1382609
9 October 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 478872
17 September 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 461452
2 July 1992 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1259077
28 June 1992 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1259075
1 May 1992 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 948039
29 April 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 954056
2 March 1992 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 957051
29 October 1991 Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1254084
26 September 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 443807
26 September 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1313200
25 September 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 155120
12 September 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 166626
24 June 1991 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 907738
6 June 1991 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1197362
29 May 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 439173
26 March 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 481511
3 February 1991 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 899960
29 January 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 924871
13 December 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 459308
10 December 1990 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1237844
9 August 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 445203
20 July 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 917892
7 June 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1216810
12 May 1990 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 903044
12 February 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 529662
24 January 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 525554
5 January 1990 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1241864
15 November 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 529389
25 October 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 528555
28 August 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 480177
29 June 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 484546
19 June 1989 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1198226
15 May 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 481287
3 May 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 902101
27 February 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 491352
16 February 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1037073
10 November 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 493016
18 October 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 458247
30 August 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 537842
8 June 1988 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 890967
1 April 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 993050
18 February 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 524604
27 October 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 501930
22 October 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 508688
16 July 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 520649
8 June 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 511976
29 May 1987 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1021949
24 April 1987 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1027394
23 March 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 536500
20 December 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 513062
28 October 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 443002
30 September 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1311818
14 September 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 494426
11 August 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 490249
17 July 1986 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1305232
9 June 1986 COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 995596
16 May 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 451147
7 February 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 465520
16 November 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 500516
18 September 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 478538
18 March 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1287477
23 February 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 531118
19 December 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 459139
16 November 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 511000
18 June 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 445458

Deficiency record · 54

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 September 2025 Resolved
The owner, master, or person-in-charge of a tank vessel must insure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10. MI observed monthly inspections required by NFPA 10 were not conducted or documented.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2025
Resolved 19 September 2025
Resolution: Vsl rep bought inspection tags and completed monthly check in presence of inspectors.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 October 2024 Resolved
Scantling, materials, and workmanship, subdivision of cargo spaces, shall be at least equivalent to the requirements of the American Bureau of Shipping. A 1/4” sized hole was discovered in the #8 void bottom plating. Identify the severity of the wasted metal, crop/renew bottom plating.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 October 2024
Resolved 15 September 2025
Resolution: Crop and renewed. Conducted air test.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 10 October 2024 Resolved
Scantling, materials, and workmanship, subdivision of cargo spaces, shall be at least equivalent to the requirements of the American Bureau of Shipping. A 1/2” hole was discovered in the subdivision bulkhead between #8 void and the void aft. Crop/renew wasted section.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 October 2024
Resolved 15 September 2025
Resolution: Cropped and renewed. Conducted air test.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 October 2024 Resolved
Scantling, materials, and workmanship, subdivision of cargo spaces, shall be at least equivalent to the requirements of the American Bureau of Shipping. Ladder in the centerline fwd void was wasted and not connected at the bottom edge. Crop/renew ladder base.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 11 October 2024
Resolution: Objective evidence was submitted diaplaying the repair of the base of the ladder.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 October 2024 Resolved
Vessels subject to initial and periodic surveys shall have annual surveys, within 3 months either way of the certificate's anniversary date. Annual not endorsed. Survey is required prior to voyage beyond the boundary.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 October 2024
Resolved 13 October 2024
Resolution: Recieved evidence that class has completed surveys.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 10 October 2024 Resolved
Each tank vessel with a cargo capacity of 1,000 or more cubic meters (approximately 6,290 barrels), loading oil or oil residue as cargo, must have one overfill device that is permanently installed on each cargo tank and meets the requirements of this section. Alarms were inoperable during inspection. Conduct troubleshooting and make necessary repairs, and conduct testing of the system to the satisfaction of the attending Marine Inspector. Vessel is restricted from loading oil or oil residue as cargo until the above requirements are met.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2024
Resolved 13 October 2024
Resolution: Receieved class report attesting to proper operation.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 25 September 2023 Resolved
Valve operating rods shall be of ample size, well guided and supported, and attached to the valve stems in a manner so as to prevent the operating rods from working loose. Operating rods on all (4) deck cargo tanks and deck cargo tank discharge line (discharge line c) valve were unable to operate the valve and were broken. Replace/rework valves and operating rods prior to cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2023
Resolved 18 October 2023
Resolution: Received photos and videos attesting to the replacement of the operating rods.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2023 Resolved
Electrical installations in hazardous locations must comply with paragraph (b)(1), (2), or (3) of this section. Vessel had broken light mount in Cargo pump room 5, operating status light on cargo pump 3, 4 & 5 cover missing, #4 cargo pump room shore power connection cracked. Cargo pump house 1 missing stuffing around electrical tube through-fitting. Repair/replace all missing light covers/brackets and electrical stuffing tube.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2023
Resolved 19 October 2023
Resolution: Received photos of the replacement and repairs of the elctrical installations in the hazardous locations.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 4 October 2021 Resolved
When table 1 references this section, a cargo containment system must have a cargo high level alarm meeting 153.409 and one of the following additional systems:(1) A second high level (cargo overflow) alarm. (2) A system that automatically stops cargo flow to the tank (automatic shutdown system). Multiple High and or Overfill alarms on the vessel did not operate properly. Vessel cannot load or discharge any cargo's that require high and overfill alarms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2021
Resolved 30 November 2021
Resolution: Tested all high and overfill alarms on all tanks. Tests SAT
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 October 2021 Resolved
Each outlet and junction box must be suitable for the environment in which it is installed and be constructed to the appropriate NEMA or IEC standard. Internal Pump House 4 and FWD bulkhead of pump house 2 contained a Junction box that is need or replacement. Replace junction boxes with appropriate new junction boxes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 30 November 2021
Resolution: All required ellectrical itelms listed were replaced and or repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 October 2021 Resolved
Each cable installation must meet - Sections 25, except 25.11, of IEEE 45-2002 Cables were found laying on the deck in pump house #4 not properly suspended and installed. Properly hang and install wires to meet standards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2021
Resolved 30 November 2021
Resolution: All wired were properly hung
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 October 2021 Resolved
Exhaust pipe installations must conform to the requirements of ABYC P-1 and part 1, section 23 of NFPA 302. Vessels was missing exhaust lagging from the exhaust side of turbo on and rain flapper to prevent water damage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2021
Resolved 12 October 2021
Resolution: Lagging was installed where required.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 October 2020 Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the assigning authority. Multiple hatch covers missing studs and securing nuts. Replaced and install missing studs and nuts.
Action required: 705 - Other - as specified
Due 15 November 2020
Resolved 4 December 2020
Resolution: Gasket, studs and nuts were replaced. All SAT
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 October 2020 Resolved
All tank vessels are subject to the regulations contained in subchapter J (Electrical Engineering) of this chapter except as such regulations are modified by the regulations in this subchapter for tank vessels. Electrical juntion box help in placed by zip ties. Install with permanent means.
Action required: 705 - Other - as specified
Due 15 November 2020
Resolved 4 December 2020
Resolution: A bracket was installed accourdingly. All SAT
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 16 October 2020 Resolved
Every tank barge shall have its name or number carved, punch-marked, or welded on the main beam. Vessel name not visible. punch or paint name on the vessel.
Action required: 705 - Other - as specified
Due 15 November 2020
Resolved 4 December 2020
Resolution: Name was painted white. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 21 September 2018 Resolved
PORT fwd set of bitts has hole worn through near base.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2018
Resolved 10 December 2018
Resolution: Bitt was repaired welding patch over hole.
Engineering › Generator (propulsion-electric) › Measurement Circuitry
Issued 17 July 2017 Resolved
While conducting COI inspection, it was determined that the AMMETER for the generator was inoperable. On board third party electrician was quick to disconnect and replace ammeter.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 July 2017
Resolved 18 July 2017
Resolution: Vessel representatives were quick to replace ammeter and prove proper installation.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 November 2016 Resolved
Vessel arrived in Morgan City on 15NOV16. Vessel will clean tanks and complete annual inspection prior to departure from MSU MC zone. COI anniversary date 90 day window will expire on 17NOV16.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 12 December 2016
Resolution: SEACREST completed maintenance and conducted annual inspection
Construction/Loadline › Hull › Hull Plating
Issued 24 March 2016 Resolved
Vsl. Allided w/ Huey P. Long bridge resulting hull, blkhd fractures and water ingress. Hull fracture in void #22 & fwd watertight blkhd void #22. Water ingress void #22 & #20. Temp repairs approved. Authorized onetime roundtrip international voyage between NOLA and Dom. Rep [name withheld], ABS damage report, marine surveyor damage report, 825_SEA CREST_3-26-16 for details.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 3 June 2016
Resolution: inspected repairs w/ ABS Surveyor [name withheld] to satisfaction of attending MI & ABS Surveyor.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 7 November 2013 Resolved
The Barges High and Overfill alarms are not operational. The alarms must be operational before loading Oil or Oil residue (Any Petroleum Product) as cargo.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 6 February 2014
Resolution: Attended vessel and tested all high level and overfill alarms. Test Sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 August 2007 Resolved
Several compression fittings were broken or the cabels were loose in the compression fittings throughout all pumprooms. Install new compression fittings where necessary and tighten loose fittings.
Action required: 705 - Other - as specified
Resolved 20 August 2007
Resolution: New compression fittings installed and loose fittings were tightened.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 14 August 2007 Resolved
Motor controller box cover was cracked. Thia would allow combustible vapor to enter box and poosibly be a fire starter. Replace cover or box and make explosionproof again.
Action required: 705 - Other - as specified
Resolved 20 August 2007
Resolution: New motor controler boxes were installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 August 2007 Resolved
Several lighting fixtures were missing globes and guards. Replace with new fixtures or replace globes and guards.
Action required: 705 - Other - as specified
Resolved 20 August 2007
Resolution: New Lighing fixtures were installed.
Deck/Cargo › Marine Portable Tanks › Pipe Connection
Issued 15 May 2006 Resolved
All deck tanks 1 - 4 must be examed by prior to use. See T/B COI. Suggested modifications must be approved prior to work commencing.
Due 15 May 2006
Resolved 19 July 2007
Resolution: Tanks are removed from service until inspected. Limitation is noted on vessel''s COI.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 28 October 2004 Resolved
Provide proof of an approved Shipboard Marine Pollution Emergency Plan for carriage of NLS (SMPEP-NLS)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 15 November 2004
Resolution: Received fax copy of G-MOR-3 letter of 12November 2004 providing interim approval of the SMPEP-NLS for the vessel.
Documentation › Certificates/Documents › NLS Certificate
Issued 28 October 2004 Resolved
Conduct Marpol Annex II exam for issuance of the Category D NLS certificate.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 15 November 2004
Resolution: Per MSC-3 letter of 27 Jan 88, vessel meets requirements for carriage of Cat D NLS.
Documentation › Certificates/Documents › IOPP Certificate
Issued 28 October 2004 Resolved
Arrange for a survey by a Coast Guard Marine Inspector to conduct an IOPP survey in accordance with 33 CFR 151.19.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 15 November 2004
Resolution: Vessel meets requirements for issuance of IOPP certificate and Form A.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 29 September 2004 Resolved
The operation of the barge is limited to domestic service only with voyages extending no more than 3 miles from land. This limitation is effective until an approved Shipboard Marine Pollution Emergency Plan for this vessel is in effect. Ref. Annex II MARPOL 73/78 regulation 16.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2005
Resolved 28 October 2004
Resolution: Cleared and reissued, to allow operation while obtaining approval of SMPEP-NLS.
Construction/Loadline › Markings
Issued 21 October 2003 Resolved
Paint Port Load Line. LEGACY COMPONENT DESC: Load Line Mark
Due 21 November 2003
Resolved 24 October 2003
Construction/Loadline › Structures
Issued 21 October 2003 Resolved
Remove overhead gasket in No. 5 pumproom.
Due 21 November 2003
Resolved 24 October 2003
Construction/Loadline
Issued 21 October 2003 Resolved
Remove or repair starboard jacobs ladder attachment.
Due 21 November 2003
Resolved 24 October 2003
Engineering › Generator (propulsion/auxiliary-electric)
Issued 21 October 2003 Resolved
Replace generator cooling hose clips with proper hose clamps.
Due 21 November 2003
Resolved 24 October 2003
Electrical › Mast
Issued 21 October 2003 Resolved
Show proper operation of port navigation light.
Due 21 November 2003
Resolved 24 October 2003
Electrical
Issued 7 October 2001 Resolved
PROVIDE APPROVED PLANS FOR INSTALLED GENERTOR AND ELECTRICAL WIRING TO OCMIHOUSTON, TX.
Condition: Unknown
Due 7 October 2001
Resolved 7 October 2001
Deck/Cargo
Issued 8 June 2000 Resolved
REPLACE/CALIBRATE PUMP DISCHARGE AND MANIFOLD GAUGES.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Deck/Cargo
Issued 8 June 2000 Resolved
PROVIDE PROOF OF SATISFACTORY TEST OF EMERGENCY SHUTDOWN.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Deck/Cargo
Issued 8 June 2000 Resolved
COMPLETE SATISFACTORY HYDRO TEST TO REPAIRED DECK CARGO PIPING IN THE PRESENCE OF A MARINE INSPECTOR. MUST BE COMPLETED PRIOR TO CARRYING CARGO.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Deck/Cargo
Issued 30 June 1999 Resolved
Drill stop and grind 7 inch crack in no. 2 transverse web in DB 2S._x001C_ Grind & weld crack in tank bottom above same web. Clean cargo tank 2s_x001C_ for inspection of suspect area. Make repairs as directed. Crack is located at 1st longitudinal starboard of centerline frame.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Navigation
Issued 30 June 1999 Resolved
Repair aft anchor light.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Deck/Cargo
Issued 30 June 1999 Resolved
Grind and repair pinhole leak in 3S doublebottom along centerline frame.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Deck/Cargo
Issued 30 June 1999 Resolved
Conduct training for all applicable tankermen and PIC on use of Cargo Record Book per 46 CFR 153.909. Submit copy of in-house memo or letter to OCMI documenting completion of training. Submit copies of Cargo Record Bookentries after completion of next 2 loads.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Fire Fighting
Issued 2 July 1996 Resolved
REMOVE FROM VESSEL OR HYDROSTATICALLY TEST PORTABLE FIRE EXTINGUISHERS IN CARGO PUMP ROOMS 1, 2, 4, 5.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Lifesaving
Issued 2 July 1996 Resolved
PROPERLY INSTALL FORWARD EYE WASH STATION. COMPLETE PRIOR TO CONDUCTING CARGO OPERATIONS.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Deck/Cargo
Issued 2 July 1996 Resolved
PROVIDE PROOF OF SATISFACTORY 150% MAWP TEST ON CARGO PIPING.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Deck/Cargo
Issued 2 July 1996 Resolved
PROVE PROPER OPERATION OF CARGO PUMP EMERGENCY SHUTDOWN LOCATED IN ELECTRICAL ROOM. COMPLETE PRIOR TO CONDUCTING CARGO OPERATIONS.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Documentation
Issued 2 July 1996 Resolved
PROVIDE PROPER TRANSFER PROCEDURES FOR VESSEL. COMPLETE PRIOR TO CONDUCTING CARGO OPERATIONS.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Deck/Cargo
Issued 22 July 1993 Resolved
NO CHLORINE MAY BE CARRIED UNTIL THE SAFETY RELIEF VALVES ARE TESTED TO _x001C_ 300 PSI OR LESS AND WITNESSED BY A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 22 July 1993
Resolved 22 July 1993
Construction/Loadline
Issued 29 April 1992 Resolved
REPAIR LEAK IN NO. 2 STBD TANK BOTTOM (2ND FRAME BACK, OFF CENTERLINE)_x001C_ AND PRESSURE TEST.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Construction/Loadline
Issued 6 June 1991 Resolved
MAKE REPAIRS TO FRACTURES IN PORT AND STBD FWD RAKES ON BOTTOM LONGS AT_x001C_ ATTACHMENT TO FRAME 3.
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Construction/Loadline
Issued 29 January 1991 Resolved
MAKE PERMANENT REPAIRS TO THE PORT BOW RAKE PRIOR TO THE CARRIAGE OF CARGO AND PRIOR TO 29 MARCH 1991 TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Deck/Cargo
Issued 12 May 1990 Resolved
MAKE VESSEL AVAILABLE FOR HYDROSTATIC TESTING OF THE CHLORINE TANKS, AND EXAMINATION OF THE EXCESS FLOW VALVES.
Condition: Unknown
Due 12 May 1990
Resolved 12 May 1990
Deck/Cargo
Issued 24 April 1987 Resolved
PROVIDE A COAST GUARD APPROVED PROCEDURES AND ARRANGEMENT MANUAL IN ACCORDANCE WITH 46 CFR 153.490.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Deck/Cargo
Issued 9 June 1986 Resolved
HYDRO-TEST FIXED CHLORINE DECK TRANSFER PIPING TO 1 1/2 TIMES MAWP NOT LATER THAN 10 JULY 1986 TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Construction/Loadline
Issued 18 March 1985 Resolved
CROP AND RENEW TO ORIGINAL DAMAGED PLATING AND FRAMING DUE TO GROUNDING IN WAY OF STARBOARD BOW. PROVIDE ACCESS TO TANKS/VOIDS DESIGNATED BY THE COAST GUARD TO EXAMINE FOR FURTHER DAMAGE.
Condition: Unknown
Due 18 March 1985
Resolved 18 March 1985

Ownership record