Records from 2007 to 2025. Most recent: inspection, 5 December 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · MADISONVILLE, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 August 2026 · expires 31 August 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Net Ton
1619 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 27
5 December 2025
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8278124
18 December 2024
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8048881
20 November 2023
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7827429
3 October 2022
Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7570395
23 May 2022
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7457436
30 July 2021
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7272483
22 May 2020
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6957844
24 April 2020
Examination of Repairs · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6944395
22 October 2019
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6839791
24 September 2019
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6819567
19 July 2018
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6484810
1 August 2017
Drydock Exam · MTSA Verification · Internal Structural Exam · Cargo Tank Internal · Examination of Repairs · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6227440
25 May 2016
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5886829
25 June 2015
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5163358
18 July 2014
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4929232
4 June 2014
MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4880209
15 October 2013
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4735735
2 August 2012
Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4389900
14 November 2011
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4188553
1 November 2010
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3882558
11 January 2010
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3669991
21 September 2009
MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3600651
31 March 2009
Administrative Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3443664
28 October 2008
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3353006
29 September 2008
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3335056
8 December 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3113485
26 July 2007
MTSA Verification · Hull Examination · Cargo Tank Internal · Internal Structural Exam · COI Inspection · Initial Construction-Excluding Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3007784
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 18 December 2024
Resolved
The cargo tank safety relief valves shall be inspected at least once in every 2 years.(b) The safety relief valve discs must be lifted from their seats in the presence of a marine inspector by either liquid, gas, or vapor pressure at least once every 5 years to determine the accuracy of adjustment and, if necessary, must be reset. PV valves observed with a test date of 2014. Replace valve or conduct a test as required and to the satisfaction of the Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 January 2025
Resolved 21 January 2025
Resolution: Receieved objective evidence attesting to the satisfactory test of the installed PVV's dated 03JAN2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2024
Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station, conspicuously marked, and located at the midpoint of such vessel, or 100 feet from the engine, whichever is the more practical. The remote quick acting manual shutdown shall be installed on the engine so as to provide a quick and effective means of stopping the engine (such as by cutting off the intake air). Company rep unable to test the remote shutdown during the inspection. Repar and conduct satisfactory test of the reomte shutdown prior to operations that require use of the pump.
46CFR32.50-35(a)
Action required: 705 - Other - as specified
Resolved 23 December 2024
Resolution: Objective evidence received, reviewed, and accepted attesting to the satisfactory test of the prime mover remote shut down.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other cargo/timber/deck/construction
Issued 5 May 2020
Resolved
No operation of Generator and Thermal Fluid Heater until plans submitted to MSC are approved.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2020
Resolved 22 May 2020
Resolution: Recieved documentation from MSC approving modifications.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 2 August 2012
Resolved
Documentation for Benzene Program not onboard.
Action required: 705 - Other - as specified
Due 2 August 2012
Resolved 2 August 2012
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 2 August 2012
Resolved
Piping system displayed vapor system identification although system was removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2012
Resolved 2 August 2012
Deck/Cargo › Cargo Heating › General
Issued 11 January 2010
Resolved
New steam coil plans not approved or reviewed by MSC yet. Restricted from loading cargo requiring steam lines to be used. Other cargoes are ok.
Action required: 705 - Other - as specified
Due 11 February 2010
Resolved 19 January 2010
Resolution: MSC reviewed the new steam coil plan dated 18DEC09, no problems noted. Engineer asked CG field unit to verify a few items.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2007
Resolved
As per 46 CFR 111.105-31 and D8 ltr dtd 15AUG07, Electrically Controlled Cargo Pump Engines onboard Tank Barges, install approved wiring harness in Class 1 Division 1 location.
Action required: 705 - Other - as specified
Due 18 June 2010
Resolved 6 April 2009
Resolution: Wiring meets Class 1 Div 1 and is satisfactorly installed IAW D8