Records from 2007 to 2026. Most recent: inspection, 27 February 2026.
Documentation record
Registered dimensions (L × B × D)356.0 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 2,099 / net 2,099
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2007
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry, non-fishing vessel
DocumentationValid · issued 6 April 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2099 - Simplified, Gross Ton
2099 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 40
27 February 2026
Periodic Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8317042
13 February 2025
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8078953
18 March 2024
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7885410
19 April 2023
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7671564
21 March 2023
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7630393
19 July 2022
Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7510136
16 May 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7452263
23 September 2021
Deficiency Check · Load Line/Change of Employment
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7319088
13 May 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7195940
23 March 2021
Periodic Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7161096
15 July 2020
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7007778
15 April 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6945707
26 February 2020
Load Line/Change of Employment
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6916343
20 February 2020
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6910782
1 March 2019
Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6634927
17 May 2018
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6417210
19 January 2018
Deadweight Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6340280
5 January 2018
Plan Review (Other than "T") · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6355271
30 June 2017
Internal Structural Exam · Drydock Exam · Cargo Tank Internal · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6191598
9 February 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6083329
16 February 2016
MTSA Verification · Administrative Inspection · Examination of Repairs · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5815749
5 February 2016
Administrative Inspection · In-Service Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5823905
22 May 2015
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5135655
17 November 2014
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5023868
3 March 2014
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4814041
2 March 2014
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4813543
24 December 2013
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4773708
17 December 2013
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4776562
11 December 2013
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4768018
17 October 2012
Examination of Repairs · Administrative Inspection · MTSA Verification · Damage Survey · In-Service Inspection · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4471899
26 January 2012
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4232456
29 November 2011
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4202833
3 November 2011
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4181435
3 June 2011
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4030815
8 December 2010
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3906935
23 September 2010
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3855595
16 September 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3858120
25 November 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3369255
21 August 2008
Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3306595
17 October 2007
Administrative Inspection · Internal Structural Exam · Initial Construction-Excluding Oversight · Cargo Tank Internal · MTSA Verification · Deadweight Survey · COI Inspection · Initial Certification · Hull Examination
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3071952
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 27 February 2026
Resolved
Operational tests and checks of all safety and limit controls, combustion controls, programming controls, and safety relief valves must be conducted by the owner, chief engineer, or person in charge at the inspection for certification, periodic inspection, and when directed by the Officer in Charge, Marine Inspection, to determine that the control components and safety devices are functioning properly and are in satisfactory operating condition. These tests and checks must be conducted in the presence of a marine inspector and must include the following: proper prepurge, burner ignition sequence checks, operation of the combustion controls, limit controls, fluid flow controls, fluid level controls, high temperature control, proper postpurge control, and verification of the flame safeguard.
Vessel was unable to demonstrate the required thermal fluid heater tests and checks. Demonstrate the above tests/checks in the presence of a Marine Inspector prior to 21June2026.
46 CFR 61.30-20
705c
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 June 2026
Resolved 26 March 2026
Resolution: Witnessed TFH testing.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 February 2025
Resolved
Grind and re-weld the following areas in the bow rake:
1. fracture on third longitudinal from bottom, stbd side
2. all welds on 3rd vertical beam from aft bulkhead on port side shell
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 March 2025
Resolution: MI verified all welds were satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 February 2025
No resolution recorded
Address the following areas prior to credit drydock:
1. Void 8S: cracked weld on the uppermost longitudinal where it meets the third vertical from aft.
2. Void 2S: cracked weld on the third longitudinal from the bottom where it meets the forward-most vertical.
3. Void 3S: cracked weld on the third from the bottom longitudinal where it meets the second vertical from the forward end of that space.
4. Void 8P: cracked weld on top longitudinal where it meets the number 1 forward-most vertical.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 23 September 2021
Resolved
If, during an internal structural examination, damage or deterioration to structural members is discovered, the OCMI may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs. Six vertical sideshell frames in four voids had associated weld fractures. Repairs are required prior to executing voyage associated with SVLLE outside of LBS route, or within 30 days.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 24 September 2021
Resolution: Accepted photos of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 March 2021
Resolved
The inspection for certification shall include an inspection of the structure, boilers, and other pressure vessels, machinery and equipment. During TFH operation, found broken relay preventing fuel pump operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 23 March 2021
Resolution: Operator discovered relay was very stiff, after securing power able to cycle relay. MI wascontacted and returned several hours later, and witnessed proper operation.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 20 February 2020
Resolved
The bulkhead between the #1 and #2 void stbd,
approximately between #1 and #2 side longs needs to
cropped and renewed at the next dry dock.
46CFR32.60-1
Action required: 705 - Other - as specified
Due 10 July 2022
Resolved 4 August 2022
Resolution: Verified final repair.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 20 February 2020
Resolved
The bulkhead in void 2 port, bay 2, approximately at
bottom long 9, needs to be cropped and renewed at the
next dry dock.
46CFR32.60-1
Action required: 705 - Other - as specified
Due 10 July 2022
Resolved 4 August 2022
Resolution: Area called out could not be verified as needing repairs. Previous repairs in the area likely incorporated this 835.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 11 December 2013
Resolved
Provide proof of testing of the cargo piping relief valves required by 33 CFR 156.170 prior to off loading cargo.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2014
Resolved 24 December 2013
Resolution: Two relief valves were tested to 125 psi and installed on barge and air tested satisfactorily. Paperwork examined and verified.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 11 December 2013
Resolved
Obtain an approved Vessel Response Plan (VRP) for barge to conduct operations in Sector Lake Michigan's Captain [name withheld] (COTP) area required by 33 CFR 155 Subpart D.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2013
Resolution: O/O obtained COTP Sector Lake Michigan authorization on thier VRP.