KONA TRADER is a 2007 freight ship. The Coast Guard has recorded 15 inspections since 2009, most recently in September 2025, along with 19 deficiencies and 1 operational control.

Records from 2009 to 2025. Most recent: inspection, 25 September 2025.

Built
2007
Last inspected
25 September 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9374208 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
911666
Flag
MARSHALL ISLANDS
—
Maury page id
psix-911666

Inspections, by type

…with no type recorded2
Years with a record 10 calendar years (2009–2025)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it39737 - Convention (Subpart B), Gross Ton
25754 - Convention (Subpart B), Net Ton
86824 - Displacement, Metric Ton
76596 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SHARON BRUSCO Towing Vessel · MISLE 94681 · 25 September 2024 · activity 8012712CLEO J BRUSCO Towing Vessel · MISLE 112765 · 25 September 2024 · activity 8012712PATRIOT Towing Vessel · MISLE 196007 · 25 September 2024 · activity 8012712

Inspection history · 15

25 September 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8241132
10 August 2025 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8200217
25 September 2024 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8012712
13 August 2024 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7973095
7 August 2024 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8033118
15 June 2021 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7225874
3 August 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6765991
9 February 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6346377
12 October 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6014807
14 July 2016 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5926224
9 October 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5002582
24 March 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4806313
2 July 2012 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4355916
4 January 2011 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3917407
23 April 2009 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3458517

Deficiency record · 19

01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Equipment (including exemption)
Issued 15 June 2021 Resolved
AFTER ANY SURVERY OF THE SHIP UNDER REGULATIONS 7, 8, 9, 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STURCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. PSCO OBSERVED PATCH REPAIR ON FIREMAIN IN BETWEEN HOLDS 6 AND 7 ON THE PORT SIDE. PSCO ALSO OBSERVED SECTIONS OF FIREMAIN REPLACED IN BETWEEN HOLDS 3 AND 4 PORT SIDE AND REPAIRS TO ANCHOR WASH PIPING IN BOSN HOLD WITH IRREGULAR WELDS. 74 SOLAS (20)I/11B AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2021
Resolved 14 July 2021
Resolution: Piping was repaired and pressure test with hose was performed satisfactory by crew. Flag/Class approved repairs.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 15 June 2021 Resolved
OIL RESIDUE MAY BE DISPOSED OF DIRECTLY FROM THE OIL RESIDUE TANKS TO RECEPTION FACILITIES OR TO ANY OTHER APPROVED MEANS OF DISPOSAL OF OIL RESIDUE. PSCO OBSERVED EVAPORATION MEANS OF DISPOSAL ENTRIES IN OIL RECORD BOOK BUT NO OTHER ACCEPTABLE MEANS ANNOTATED IN ITEM 3.2 OF THE SUPPPLEMENT TO THE IOPP. MARPOL I/12.2 50 AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2021
Resolved 29 June 2021
Resolution: Vessel submitted a new IOPP Form A that had evaporation listed as an approved method of sludge disposal.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 9 February 2018 Resolved
0740-Pumps-Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. The emergency fire pump is unable to provide adequate water pressure to the ship's fire main. 74SOLAS(2009) II-2/14.2.1.2-30abc
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2018
Resolved 11 February 2018
Resolution: Received Class Report from BV and USCG PSC Inspectors attended the vessel.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 9 February 2018 Resolved
0725-Fixed fire extinguishing installation-Fire fighting systems and appliance shall be kept in good working order and readily available for immediate use. The valve on the hypermist system leading to the fresh water tank was found in the closed position. 74SOLAS(2009)II-2/14.2.1.2-30abc
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2018
Resolved 11 February 2018
Resolution: Received Class Report from BV and USCG PSC Inspectors attended the vessel.
Personnel › Training › Familiarization Training
Issued 9 February 2018 Resolved
0299-Other (crew)-Every candidate for certification shall have completed approved education and training and meet the standard of competence specified in section A-III/1 of the STCW Code. The crew was not familiar with operating the oily water separator. STCW III/1.2.4-17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2018
Resolved 11 February 2018
Resolution: Received Class Report from BV and USCG PSC Inspectors attended the vessel.
Engineering › Fuel Oil Service System › Pump
Issued 9 February 2018 Resolved
1499-Other (Prop & Aux Machinery)-Means shall be provided to control leaks of flammable liquids. The high pressure fuel oil pumps on cylinders one and five of the main engine are leaking fuel oil. 74SOLAS(2009)II-2/4.1.1-17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2018
Resolved 11 February 2018
Resolution: Received Class Report from BV and USCG PSC Inspectors attended the vessel
Engineering › Fuel Oil Service System › Filter
Issued 9 February 2018 Resolved
1499-Other (Prop & Aux Machinery)-Means shall be provided to control leaks of flammable liquids. The fuel oil purifier was found to be leaking fuel oil at an abnormal rate. 74SOLAS (09) II-2 4.1.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2018
Resolved 11 February 2018
Resolution: Received Class Report from BV and USCG PSC Inspectors attended the vessel.
Engineering › Lubricating Oil Service System › Pump
Issued 9 February 2018 Resolved
1499-Other (Prop & Aux Machinery)-The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected to reduce to a minimum, any danger to persons on board. Lube oil was found to be leaking from the number one steering gear pump. 74SOLAS(2004)II-1/26.1-17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2018
Resolved 11 February 2018
Resolution: Received Class Report from BV and USCG PSC Inspectors attended the vessel.
Engineering › Lubricating Oil Service System › Purifier
Issued 9 February 2018 Resolved
1499-Other (Prop & Aux Machinery)-The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected to reduce to a minimum, any danger to persons on board. Excessive steam was found to be leaking from the vessel's lube oil purifier. 74SOLAS(2004)II-1/26.1-40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 March 2018
Resolved 11 February 2018
Resolution: Received Class Report from BV and USCG PSC Inspectors attended the vessel.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 9 February 2018 Resolved
1499-Other (Prop & Aux Machinery)-Means shall provided to control leaks of flammable liquids. The number five port side fuel oil tank valve was found to be leaking. 74SOLAS(2009)II-2/4.1.1-40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 March 2018
Resolved 11 February 2018
Resolution: Received Class Report from BV and USCG PSC Inspectors attended the vessel.
Construction/Loadline › Structures › Deck Plating
Issued 9 February 2018 Resolved
1240-Cargo and other hatchways-Coamings and hatchways covers to exposed hatchways on decks above the superstructure deck shall comply with the requirements of the Administration. Fractures were found on coaming brackets for cargo holds three, four, and five. ICLL 14.2-40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 March 2018
Resolved 11 February 2018
Resolution: Received Class Report from BV and USCG PSC Inspectors attended the vessel.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 24 March 2014 Resolved
9800 Other (clearly hazardous) - Incomplete VRP onboard missing contacts, sections, and not available for exam. Make available for exam, onboard and valid, prior to departure. - 33 CFR 155 Subchapter J - 17 c/
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2014
Resolution: Vessel provided approved and complete VRP.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 24 March 2014 Resolved
0750 Fire Prevention- Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order so as to ensure their required performance in these divisions. Class "A" fire doors in galley have deteriorating gasket material (4 doors total). - 74 SOLAS (09) II-2/14.2.1.1.1 - 17 a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2014
Resolution: Received class report from NKK attesting to satisfactory repairs.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 24 March 2014 Resolved
0100 - Vessel must have onboard a valid original of the Certificate of Registry. - Merchant Shipping Act Section 16(1) - 40 c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 October 2014
Resolution: Received proper documentation from Flag satisfying the requirement.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 24 March 2014 Resolved
0750 Fire Prevention- Structural fire protection, openings and penetrations shall be kept in good order, to ensure performance. Class "A'" fire doors throughout vessel are in poor condition. - 74 SOLAS (09) II-2/14.2.1.1.1 - 40 a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 March 2014
Resolution: Received class report from NKK attesting to satisfactory repairs.
Lifesaving › Lifeboat › Hull
Issued 2 July 2012 Resolved
0610 - Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immeidate use. the solas retroreflective tape on the topside of the starboard and port life boats is worn and not capable of reflecting light properly. 74 Solas (09 cons) III/20.2 (10 C) Corrected on the spot.
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 2 July 2012
Resolution: New retroreflective stripping was applied to the topside of the starboard and port life boats.
Lifesaving › Lifeboat Equipment › Seasickness Bag
Issued 2 July 2012 Resolved
0611 - Each survival craft shall be fully equipped as required by this chapter and the code. Sea sick pills in the port and starboard life boat are expired. 74 Solas (09 Cons) III/13.1.4 (10 C) Corrected on the spot.
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 2 July 2012
Resolution: New sea sick medication was ordered in the presence of the Coast Guard Examiner.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 2 July 2012 Resolved
0199 - The Master of each vessel equipped with ballast tanks must provide the following information, in written form, to the Captain of the Port. Notifications to the NBIC were not made. 33 CFR 151.1516(a). (10 C) Corrected on the spot.
Due 2 July 2012
Resolved 2 July 2012
Resolution: Vessel submitted porper ballast water report to NBIC and conformation email was submitted to the Coast Guard Examiner before completion of vessel exam.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 4 January 2011 Resolved
0199 - Other (certificate) - Crew has not conducted appropriate hydrostatic test on bunkering lines. Conduct test prior to bunkering in the United States and provide written documentation to the US Coast Guard. - 33CFR156.170
Action required: 705 - Other - as specified
Due 10 January 2011
Resolved 6 January 2011
Resolution: Received, reviewed, and accepted proper documentation from vessel stating the deficiency was rectified. Vsl conducted satisfactory hydrostatic test.