MAURY USCG vessel records Sign in
← All vessels

GREY SHARK

GREY SHARK is a 1980 freight ship. The Coast Guard has recorded 103 inspections since 2007, most recently in March 2017, along with 148 deficiencies — 4 with no resolution recorded — and 37 operational controls.

Records from 2007 to 2017. Most recent: inspection, 10 March 2017.

Built
1980
Last inspected
10 March 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7907647 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
912591
Flag
PANAMA
—
Maury page id
psix-912591

Inspections, by type

…with no type recorded48
…past their stated due date1
Years with a record 10 calendar years (2007–2017)
The 103 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it4688 - Convention (Subpart B), Gross Ton
1799 - Convention (Subpart B), Net Ton
4890 - Displacement, Ton
2877 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CATHERINE C MILLER Towing Vessel · MISLE 204293 · 29 July 2015 · activity 5200863QUANTICO CREEK Towing Vessel · MISLE 1077107 · 29 July 2015 · activity 5200863

Inspection history · 103

10 March 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6102512
19 February 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6091054
8 February 2017 PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6084483
8 February 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6085163
30 November 2016 Deficiency Check · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6049693
30 November 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6050229
27 September 2016 ISPS I Exam · Deficiency Check · Ballast Water Examination · PI Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6009905
16 September 2016 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6002100
12 September 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5999166
12 September 2015 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5721032
14 August 2015 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5216121
5 August 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5207099
29 July 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5199529
29 July 2015 PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5200173
29 July 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5200863
28 July 2015 ISPS III Exam · PII Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5198419
14 October 2014 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5004634
4 August 2014 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4943421
3 August 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4942811
24 March 2014 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4818466
10 July 2012 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4374150
9 July 2012 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4373647
18 May 2012 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4314708
17 February 2012 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4241896
12 February 2012 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4243344
11 January 2012 ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4221819
11 January 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4223182
6 January 2012 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4220157
5 January 2012 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4219117
21 September 2011 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4150954
16 August 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4116493
6 July 2011 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4071706
14 February 2011 PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3944009
9 February 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3942392
20 January 2011 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3930073
13 January 2011 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3925867
18 December 2010 Ballast Water Examination · PI Safety Exam · ISPS III Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3912460
11 December 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3908744
15 November 2010 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3891566
23 October 2010 PI Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3875993
19 October 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3873166
12 October 2010 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3868450
1 October 2010 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3860911
15 March 2010 ISPS II Exam · Deficiency Check · PI Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3695829
15 March 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3696161
13 March 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3695088
9 March 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3692327
27 January 2010 ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3670964
23 January 2010 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3667339
21 January 2010 PI Safety Exam · ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3667253
29 December 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3656573
27 December 2009 MARPOL Annex V Examination · Ballast Water Examination · ISPS III Exam · PI Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3655339
17 December 2009 Ballast Water Examination · PI Safety Exam · ISPS III Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3651627
17 December 2009 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3652035
11 December 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3648557
7 July 2009 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3527000
2 July 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3521537
28 April 2009 MARPOL Annex V Examination · MARPOL Annex I Examination · Random ISPS/MTSA/PSC · ISPS III Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3462760
26 April 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3461696
23 March 2009 Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3439002
5 March 2009 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3428255
27 January 2009 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3400970
20 January 2009 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3396755
6 January 2009 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3389260
29 December 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3384958
29 December 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3386147
28 December 2008 MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · ISPS III Exam · PI Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3385500
14 October 2008 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3341441
16 July 2008 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3269885
26 June 2008 Administrative Inspection · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · Loadline Exam · ISPS II Exam · ILO-147 Exam · STCW 95 Exam · PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3248745
25 June 2008 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3247748
11 June 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3233946
6 June 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3231499
6 June 2008 Deficiency Check · Spot Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3231545
4 June 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3227732
3 June 2008 MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3225825
3 June 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3226736
3 June 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3226978
2 June 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3228994
13 March 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3163542
11 March 2008 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3162367
9 March 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3160979
3 March 2008 Type not recorded
No type recorded · Station Fort Pierce · USCG Southeast District (CGD-SE) · Activity 3157946
15 February 2008 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3148135
15 February 2008 ILO-147 Exam · ISPS III Exam · PII Safety Exam · MARPOL Annex V Examination · Loadline Exam · MARPOL Annex I Examination · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3148186
12 February 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3146212
11 February 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3145762
9 February 2008 MARPOL Annex V Examination · PI Safety Exam · MARPOL Annex I Examination · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3144303
7 February 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3143629
7 February 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3143634
27 December 2007 MARPOL Annex V Examination · Administrative Inspection · ISPS III Exam · MARPOL Annex I Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3121363
1 December 2007 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3107492
29 November 2007 Deficiency Check · ISPS III Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3106378
28 November 2007 Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 3105725
6 November 2007 MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · STCW 95 Exam · ISM Exam · ILO-147 Exam · Loadline Exam · PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3094076
5 November 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3093205
16 October 2007 Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3080762
16 October 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3081662
7 October 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3074955
7 October 2007 ISPS II Exam · PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3074995
13 September 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3056569
9 September 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3053382
9 September 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3053474

Deficiency record · 148

Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 8 February 2017 Resolved
Ships equipment shall be maintained to ensure the ship can proceed to sea without presenting an unreasonable threat to the marine environment. Internal transfer system from the bilge well to the holding tank is not adequate to properly manage the engine room generated oily mixture. MARPOL Annex. 1 Reg 6.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2017
Resolution: Received report from the administration attesting to the installation of the above listed internal pumping arrangement.
Lifesaving › Launching Appliances › Davit
Issued 8 February 2017 Resolved
Safety devices shall be fitted which will automatically cut off the power before the davits come against the stops in order to avoid overstressing the wire rope falls or davits. Limit switches were were inoperable during the lifeboat recovery drill. 60 SOLAS Ch.III Reg 36(k)
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: Deficeincy rectified on the spot.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 8 February 2017 No resolution recorded
Food rations determined by the administration shall be provided for each person the lifeboat is certified to carry. 8 of 16 food rations were compromised and not airtight. 60 SOLAS Ch.III Reg. 2(a)(xiii)
Action required: 705 - Other - as specified
Due 22 February 2017 — due date passed with no resolution recorded
Documentation › Logs/Records › Oil Record Book
Issued 8 February 2017 No resolution recorded
The oil record book shall be completed on each occasion on a tank to tank basis. During review of the ORB entries attesting to ship's bilge to tank #13 were omitted.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Deck/Cargo › Cargo Stowage › General
Issued 4 December 2016 Resolved
CARGO SHALL BE LOADED, STOWED, AND SECURED THROUGHOUT THE VOYAGE IN ACCORDANCE WITH THE CARGO SECURING MANUALAPPROVED BY THE ADMINISTRATION. CARGO IS NOT SECURED IN ACCORDANCE WITH THE CARGO SECURING MNAUAL. VEHICLES ARE LASHED THROUGH TIRES, TO OTHER VEHICLES, LACK PROPER NUMBER OR PLACEMENT OF LASHINGS, OR ARE LASHED INSECUREL, AMONG OTHER ISSUES. 74 SOLAS (14 CONS) VI/5.6
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2016
Resolved 10 December 2016
Resolution: CORRECTED TO THE SATISFACTION OF FLAG AND COAST GUARD
Deck/Cargo › Cargo Stowage › General
Issued 4 December 2016 Resolved
THE CARRIAGE OF DANGEROUS GOODS IN PACKAGED FORM SHALL BE IN COMPLIANCE WITH THE RELEVANT PROVISIONS OF THE IMDG CODE. VEHICLES ARE NOT SUBJECT TO THIS CODE IF THERE ARE NO SIGNS OF LEAKAGE FROM THE BATTERY, ENGINE, OR FUEL TANK WHEN APPLICABLE. SEVERAL VEHICLES ARE LEAKING FROM FUEL PANS. 74 SOLAS (14 CONS) VII/3, IMDG CODE 3.3.961
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2016
Resolved 10 December 2016
Resolution: CORRECTED TO THE SATISFACTION OF FLAG AND COAST GUARD
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 1 December 2016 Resolved
DEF # 01 -1110- CARGO SHALL BE LOADED, STOWED, AND SECURED IN ACCORDANCE WITH THE CARGO SECURING MANUAL APPROVED BY THE ADMINISTRATION. CURRENT CARGO SECURING MANUAL NOT APPROVEDBY ADMINISTRATION OR CLASS. 74 SOLAS (14 CONS) VII/5 17BC
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 2 December 2016
Resolved 4 December 2016
Resolution: Flag and RO approved securing manaul.
Lifesaving › Lifeboat › Propulsion Casing/Protection
Issued 1 December 2016 Resolved
DEF #02 -0610- THE NORMAL EQUIPMENT OF EVERY LIFEBOAT SHALL CONSIST OF: A MAST OR MASTS, WITH GALVANIZED WIRE STAYS TOGETHER WITH SAILS (COLOURED ORANGE). THE SAIL RIGGING, TO INCLUDE THE MAST, ARE IN POOR CONDITION ON PORT LIFEBOAT. 60 SOLAS III/11(a)(vi) 17BC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 December 2016
Resolved 4 December 2016
Resolution: New mast provided. Crew knows how to rig.
Lifesaving › Lifeboat › Propulsion Casing/Protection
Issued 1 December 2016 Resolved
DEF #03 -0925- THE MUSTERS AND INSPECTIONS SHALL BE ARRANGED SO THAT THE CREW THROUGHLY UNDERSTAND AND ARE PRACTISED IN THE DUTIES THEY HAVE TO PERFORM. CREW MUSTERS DO NOT INVOLVE DEPLOYING OF SAIL RIGGING. 60 SOLAS III/26(C)
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 2 December 2016
Resolved 8 February 2017
Resolution: Verified records of completed drill in ships offical logboog along with photographic records attesting to completion of the above referenced drill.
Stability › Weathertight Integrity › General
Issued 1 December 2016 Resolved
DEF # 04 - 0988- THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO SHIP OR PERSONS ON BOARD. FORWARD PORT SIDE WEATHER DECK HAS HOLE IN PLATE IN FRONT OF EMERGENCY GENERATOR SPACE. 74SOLAS(14CONS.) I / 11 16B
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 8 February 2017
Resolution: Hole has been repaired.
Lifesaving › Lifeboat › Propulsion Casing/Protection
Issued 1 December 2016 Resolved
DEF # 05 -0610 THE LIFEBOAT ENGINE AND ITS ACCESSORIES SHALL BE SUITABLY ENCLOSED TO ENSURE OPERATION UNDER ADVERSE WEATHER. STBD LIFEBOAT FUEL TANK IS GLUED TO STBD SIDE BUYANCY COMPARTMENT 60SOLAS III / 9(a)(iii) 50B
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2016
Resolved 8 February 2017
Resolution: Condition identified above has been rectified.
Fire Fighting › Ventilation Systems › Fans
Issued 1 December 2016 No resolution recorded
SUCH MEASURES AS ARE PRACTICABLE SHALL BE TAKEN IN RESPECT OF CONTROL STATIONS SITUATED BELOW DECK AND OUTSDIED MACHINERY SPACES IN ORDER TO ENSURE VENTILATION IS MAINTAINED. TRAILER DECK VENT FWD OF HOUSE ON PORT SIDE AND INNER BOTTOM BLOWER LOCATED ABOVE THE EMERGENCY GENERATOR SPANCE AND INNER BOTTOM BLOWER ON STBD SIDE FWD OF EMBARKATION LADDER ARE INOPERABLE 60SOLAS II / 47 (d) 50B
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Deck/Cargo › Mooring/Anchoring › Standard Link (anchor chain)
Issued 1 December 2016 No resolution recorded
# 07 CODE 1320 THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. SEVERAL ANCHOR CHAIN LINKS ARE WASTED AND HAVE BROKEN OFF ON BOTH ANCHOR CHAINS. 74 SOLAS (14 CONS) I / 11 action: 50b
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 December 2016 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. BOTTOM CARGO DECK HAS THREE LARGE BILGE WELL HOLES WHICH ARE NOT COVERED OR COVERED INADEQUATELY WITH MESH GRATES. 74 SOLAS (14 CONS) I / 11 action: 50b
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 December 2016
Resolved 8 February 2017
Resolution: Condition identified above has been rectified.
Lifesaving › Inflatable Liferafts › Float Free
Issued 1 December 2016 Resolved
#09 CODE 0620 ALL LIFE SAVING APPLIANCES SHALL BE AVAILABLE FOR IMMEDIATE USE. LIFERAFTS WERE RATCHET STRAPPED TO THE LIFERAFT FRAM MOUNT. 60 SOLAS III / 4(c) action: 10 c
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 1 December 2016
Resolution: Corrected on the spot.
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 1 December 2016 Resolved
#10 CODE 1699 CARGO SHIPS WHEN ENGAGED ON INTERNATIONAL VOYAGES, SHALL BE FITTED WITH A VOYAGE DATA RECORDER WHICH MAY BE A SIMPLIFIED VDR. VDR DISPLAYED ERRROR MESSAGE READING “BACKUP NOT RECORDING”. 74 SOLAS (14 CONS.) V / 20.2.2 action: 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 1 December 2016
Resolution: Corrected on the spot.
Engineering › Fuel Oil Service System › Piping
Issued 27 September 2016 Resolved
0900 - After any survey of the ship has been completed no change shall be made in the structural arrangment of the machinery. Fuel that leads from the day tank to the overflow tank is leaking diesel into the bilge - 60 SOLAS CH.I/11 - 17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2016
Resolution: Flag attested to repairs. Coast Guard def check follow-up onboard found all repairs to meet attestation.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 September 2016 Resolved
0750 - The construction at all doors of A class division shall provide resistance to fire and the passage of smoke and flame. Fire door leading into galley does not meet class A standing - 60SOLAS CH.2/38(d) - 16bc
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 3 October 2016
Resolution: Flag attested to repairs. Coast Guard def check follow-up onboard confirmed attestation.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 14 August 2015 Resolved
According to the ships original Fire Washdown Plan, serviceable non-return valves should be installed on the discharge side of all fire pumps (two primary fire pumps and one emergency fire pump) to ensure the system's readiness. Additionally, the fire main system has been modified such that the ballast system has been cross-connected into the fire main system. See form B. 60SOLAS CHIIReg11
Action required: 705 - Other - as specified
Resolved 22 September 2015
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 14 August 2015 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this reg, the req of the Code shall be treated as mandatory. The company should establish and maintain procedures to control all documents and data which are relevant to the safety management system. See form B. 74 SOLAS(14)Ch. IX, Reg. 3, ISM Code, Part A, Para 11
Action required: 705 - Other - as specified
Resolved 22 September 2016
Resolution: CVC-2 reviewed documentation letter# 008-16 allowing vessel entry to us after PI exam is completed subject to COTP discretion
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 29 July 2015 Resolved
2335-Development of plans for shipboard ops-Every company should develop, implement, and maintain an SMS which includes instructions and procedures to ensure safe operation of ships and protection of the environment. Vessel ,must implement written procedures for the testing of the steering gear and alignment of the fire main for emergency use. 74SOLAS(14) IX/3.1, ISM 1.4.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2015
Resolution: See narrative for MISLE Activity 5721032
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 29 July 2015 Resolved
0950-Electric equipment in general-Each separate circuit shall be protected against short circuit. Each separate circuit shall also be protected from overload. Vessel experienced loss of power under increased load while underway. Vessel must determine root cause and effect proper repair. 60SOLAS II/27(a)(vii)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2015
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 28 July 2015 Resolved
IN CARGO SHIPS OF LESS THAN 5000 TONS GROSS TONNAGE THERE SHALL BE A SELF CONTAINED SOURCE OF EMERGENCY POWER CAPABLE OF SUPPLYING THE ILLUMINATION AT LAUNCHING STATIONS AND STOWAGE POSITIONS OF SURVIVAL CRAFT. EMERGENCY GENERATOR FAILED TO START DUE TO A LOOSE BATTERY CONNECTION.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2015
Resolved 28 July 2015
Resolution: CREW CLEANED BATTERY TERMINAL AND TIGHTENED CONNECTION SO THAT THE GENERATOR STARTED AND OPERATED AS IT SHOULD.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 28 July 2015 Resolved
THE EMERGENCY FIRE PUMP SHALL BE CAPABLE OF SUPPLYING TWO JETS OF WATER TO THE SATISFACTION OF THE ADMINISTRATION. PSCO OBSERVED EMERGENCY FIRE PUMP IS NOT CAPABLE OF PRODUCING SUFFICIENT PRESSURE TO SUPPLY TWO JETS OF WATER.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2015
Engineering › Reduction Gearing/Clutches › Gear
Issued 14 October 2014 Resolved
The vessel is configured with dual shaft propulsion and the gear box on the starboard engine is out of order. Vsl is unable to clutch in on the stbd shaft which has limited propulsion to one shaft. 74 SOLAS (09 CONS) CH I, Regulation 11a.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2014
Resolution: Attended vessel and verified the affected machinery was repaired IAW with tech report. Witnessed operation of engine and gear box was operating/functioning normal.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 24 March 2014 Resolved
0820-The condition of the ship shall be maintained to conform with the provisions of the present regulations. The lagging on the stbd main engine is wasted and blackened with exhaust. - 74SOLAS(09) I/11a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 14 April 2014
Resolution: The vessel submitted to the USCG a Class Technician''s report attesting to the satisfactory installation of new non-combustible, heat shield lagging on the stbd side of the main engine. Deficiency cleared.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 24 March 2014 Resolved
0820-The condition of the ship shall be maintained to conform with the provisions of the present regulations. The lagging on the aft generator e is wasted and blackened with exhaust. - 74SOLAS(09) I/11a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 14 April 2014
Resolution: The vessel submitted to the USCG a Class Technician''s report attesting to the satisfactory installation of new non-combustible, heat shield lagging on the exhaust piping of the aft generator. Deficiency cleared.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 17 February 2012 Resolved
1230 Rails on port side of water deck shall be provided for the protection of the crew in getting to and from their quarters. Rails are fractured and shall be satisfactorily replaced. ICLL 1966 2005 ED. CH.II REG. 25(4)
Action required: 705 - Other - as specified
Due 2 March 2012
Resolved 29 April 2012
Resolution: Hand rails were found repaired to the satisfaction of the USCG PSCO.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 11 January 2012 Resolved
1410- Propulsion main engine- Main engine high pressure diesel fuel pumps are leaking excessively port main engine pumps 2,3,5,7,9 and Starboard side main engine pumps 5 and 9. SOLAS Ch. 1/11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 17 January 2012
Resolution: Received, reviewed, and accepted class report from Macosnar Corp. Ships engineers repaired all fuel leaks on both main engines and tested at incremental rpm points, temperatures and engine parameters were tested.
Engineering › Bilge Water Management System › Not Operational
Issued 11 January 2012 Resolved
1099- Other(alarm-signals) Engine room bilge alarms are inoperable. Solas09Cons. Chapter 1 Reg 11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2012
Resolution: Received, reviewed and accepted class report from Macosnar Corp attesting to new cables installed by Unique Electric Inc. All bilge alarms tested to surveyor satisfaction.
Lifesaving › Lifeboat Equipment › Electric Torch
Issued 11 January 2012 Resolved
0611- Lifeboat Inventory- Normal equipment of every lifeboat shall consist of a lamp with oil sufficient for 12 hours, 2 boxes of suitable matches in a watertight container. These items are missing. Solas60 Ch. 3 Reg 11.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 February 2012
Resolved 17 January 2012
Resolution: Received, reviewed, and accepted class report from Macosnar Corp. Oil lamp and two boxes of suitable matches in a watertight container has been added to lifeboat inventory.
Electrical › Electric Generation Source (emergency) › Generator
Issued 11 January 2012 Resolved
1430- Auxilary Engines- Emergency generator does not take load automatically when main ship power is lost. Solas 09 Cons. Ch. 1 Reg 11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2012
Resolution: Received, reviewed, and accepted class report from Macosnar Corp attesting to proper repair and function of the emergency generator. Emergency generator now able to take load automatically when normal power is lost.
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 11 January 2012 Resolved
1330- Winches and Captsans-Aft port and starboard mooring windlass has hydraulic oil leaking onto the deck from the windlasses control rod. Solas 09 Cons. Chapter 1 Reg 11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2012
Resolved 17 January 2012
Resolution: Received, reviewed and accepted class report from Macosnar Corp attesting to the repair to hydraulic oil leakages found on the mooring windless port and starboard. Oil seals replaced.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 11 January 2012 Resolved
1150- Loading and unloading equipment- Aft port side vehicle ramp controller for brake is leaking hydraulic fluid. Solas 09 Cons. Ch. 1 Reg. 11
Action required: 705 - Other - as specified
Due 11 February 2012
Resolved 17 January 2012
Resolution: Received, reviewed and accepted class report from Macosnar Corp attesting to leak repairs.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 11 January 2012 Resolved
9900- Other (not clearly hazardous) QI notification drills shall be conducted quarterly, prior to entering US exclusive economic zone. Documentation of this exercise shall be maintained onboard for a minimum of 3 years. QI notification drill records are not readily available. 33USC1321
Action required: 705 - Other - as specified
Due 11 February 2012
Resolved 12 February 2012
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 11 January 2012 Resolved
9900- Other( not clearly hazardous) Captain is unaware of requirement of EPA's Vessel General Permit. Vessel owner/ operator is to submit a notice of intent to EPA. VGP Part 1.5.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2012
Resolution: Received EPA Notice of Intent.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 January 2012 Resolved
0950- Electrical equipment in general- Heater sitting in water in forward sewage compartment, this caused a fire/shock hazard. Solas 60 Ch. 2 Reg 27 (a) (iv) (2)
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 11 January 2012
Resolution: Removed heater from space.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 11 January 2012 Resolved
0999- Other( safety in general)- In the forward sewage compartment the piping for the sewage plant is secured to the overhead by zip ties. Solas 60 Ch. 1 Reg 11
Action required: 705 - Other - as specified
Due 11 February 2012
Resolved 12 February 2012
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 January 2012 Resolved
1230- Railing catwalks- Starboard lifeboat embarkation deck guard rail is missing bottom most rail. ILLC 05 Cons. Ch. 2 Reg 25(3)
Action required: 705 - Other - as specified
Due 11 February 2012
Resolved 12 February 2012
Electrical › Electric Generation Source (service) › Generator
Issued 21 September 2011 Resolved
1430 - Auxiliary engines - #1 generator inoperable w/o class knowledge/approval; . Vessel is fitted with portable generator on deck of sufficient power, but lacks capability to parallel with main generator. No remote emergency shutdown capability presents a personnel and fire hazard to the crew. Rectify to class approval. See Narrative for further explanation of condition. [SOLAS 60 Ch. I/11]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2011
Resolution: Received, reviewed, and accepted Administration report attesting to acceptance of current arrangement of vessel''s auxiliary Engines. Also received tech report from [name withheld] attesting to repair and proper function of vessel''s auxiliary engines.
Fire Fighting › Fire Main › Condition
Issued 12 February 2011 Resolved
Fire-fighting system and appliances shall be kept in good working order. Fire main pipe on 02 deck starboard side is holed. Make necessary repairs to the satisfaction of the Administration prior to departure. SOLAS II / 2-14.2.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2011
Resolution: Received report attesting to the proper repairs.
Electrical › Electric Generation Source (emergency) › Generator
Issued 12 February 2011 Resolved
Provisions shall be made for the testing of the emergency source of power. Due to repairs being conducted unable to test emergency generator. Provide report attesting to the proper working condition of the emergency generator to the satisfaction of the Coast Guard prior to departure. (60) SOLAS Reg 25 . (h)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2011
Resolution: Received report attesting to the proper functioning of the emergency generator.
Accommodation/Occupational Safety › Ventilation › General
Issued 12 February 2011 Resolved
Adequate power ventilation shall be provided in closed cargo spaces. Forward ventilation system is n not operational. make necessary repairs to the satisfaction of the Administration prior to departure. SOLAS II / 2 - 19.3.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2011
Resolution: Received report attesting to the acquisition of parts needed to complete repairs. COTP allow for repairs to be conducted at the next port of call.
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 January 2011 Resolved
Vessels STBD engine raw water cooling line for the air cooler has a temporary soft patch. The patch has not been approved by vessels class. Temp. and permenant repairs must be approved by class.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2011
Resolved 13 January 2011
Resolution: Recieved class report approving temp. repairs to SW pipe.
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 18 December 2010 Resolved
Found piping insulation on freshwater system with multiple temporary repairs as well as broken piping in the system. System was not found to be leaking. System to be repaired to the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 January 2011
Resolution: The piping system has been determined to be an old sewage line that is no longer in use.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 18 December 2010 Resolved
Vessel could not produce recorded history of echo depth sounder.
Action required: 705 - Other - as specified
Resolved 20 December 2010
Resolution: Vessel provided pictures of the recorded history as well as the menu screen for recorded history of echo depth sounder.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 23 October 2010 Resolved
A duplicate set of fire control plans or a booklet containing such plans shall be permanently stored in a prominently marked weathertight enclosure outside the deckhouse for the assistance of shore-side fire-fighting personnel. Fire control plan is locked inside the cargo area inside the SOPEP locker and cannot be accessed from outside the ship.
Action required: 705 - Other - as specified
Due 30 October 2010
Resolved 9 November 2010
Resolution: Vessel''s Master submitted pictures to show that Fire Control Plan now permanently affixed and marked outside of the SOPEP locker.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 23 October 2010 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The anchor chain safety housing pieces had greater than 50% wastage and are dangerous to personnel operating the anchor equipment should the pieces break.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2010
Resolved 9 November 2010
Resolution: Vessel''s anchor chain safety housing pieces were replaced. Pictures submitted by Master.
Fire Fighting › Fire Hoses › Condition
Issued 15 March 2010 Resolved
One fire hose was found holed and wasted making it unserviceable with no spares available. Vessel is to obtain a new fire hose to the satisfaction of the attending Coast Guard inspector prior to departure. SOLAS 60 Ch II Reg. 56
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2010
Resolution: Sector New York received confirmation that the ship purchased 03 new fire hoses.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 March 2010 Resolved
Railing on the port side main deck next to forward and aft port vents and next to port and starboard aft towing bits are broken or missing. Vessel is to repair railing to the satisfaction of attending classification society as per ICLL 1966 Article 15.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 March 2010
Resolution: Received Class report attesting to railing repaired according and to the satisfaction of RO surveyor.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 15 March 2010 Resolved
PVC piping installed in the overhead forward in the elevated car deck was found to be broken and repaired with duct tape in several instances. This is to be renewed to the original condition to the satisfaction of attending flag surveyor prior to next U.S. port after sailing foreign. SOLAS I Reg II
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 March 2010
Resolution: Received Class report attesting to all damge/broken pvc pipe were repaired/renewed according and to the satisfaction of RO surveyor.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 15 March 2010 Resolved
Vessel has copies of both the Continuous Synopsis Record and Safety Management Certificate. Vessel is to obtain original documents. Vessel is to rectify the deficiency to the satisfaction of attending class surveyor prior to next US port after sailing foreign as per SOLAS 04 Ch XI-1 Reg 5 and SOLAS 04 Ch IX Reg 4.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 March 2010
Resolution: Received Class report attesting orginal CSR and SMC are kept on board.
Construction/Loadline › Hull › Side Shell
Issued 2 February 2010 Resolved
Vessel is to affect permanent repairs in vicinity of aft port side damaged hull as noted on vessel damage report dated 13 Jan 2010. ICLL 66
Action required: 705 - Other - as specified
Due 16 February 2010
Resolved 24 February 2010
Resolution: All hull aft parts on the port and starboard side affected during the bad weather in Haiti, were crop and renew for new plate and butt welded, according to surveyor''s instructions.
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 2 February 2010 Resolved
Vessel administration is to approve modification in vicinity of paint locker door, (hole fabricated and fire fighting nozzle mounted) amend fire plan if necessary. ICLL 66 Annex 1-18
Action required: 705 - Other - as specified
Due 16 February 2010
Resolved 16 February 2010
Resolution: The paint locker was re-located was relocated on the welder locker. The new paint locker has 1 portable powder and 1 wheel powder extinguisher 5 Kg a 50 Kg. The fire Control and Safety Plan was modified in accordance with modification.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 2 February 2010 Resolved
Paint locker has unauthorized combustibles (cardboard, tools etc) and is in need of re-stowing of paint and organizing. SOLAS 60 2-2/18.7
Action required: 705 - Other - as specified
Due 16 February 2010
Resolved 24 February 2010
Resolution: The paint locker was re-located on the welder locker, The new paint locker is only authorized to store paint and thinners. The Fire Control and Safety Plan was modified to reflect changes.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 2 February 2010 Resolved
Vessel's ER bilges are excessively filled with oil and in need of pump out. Correct the same. SOLAS 60/2-34
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 February 2010
Resolved 24 February 2010
Resolution: The vessel disposed 30 cubic meters of sludge in Santo Domingo Port. The company Atlantic Shipping provided one Sludge Certificate; this certificate is keep on board and was noted in the Oil record Book.
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 February 2010 Resolved
Emergency battery box located on top pilot house. The batteries are not stowed properly (blocked. braced) and box is holed. repair the same. SOLAS 60 2-27a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 February 2010
Resolved 24 February 2010
Resolution: The battery box was repaired and the batteries were blocked / braced.
Navigation › Piloting/Steering › Gyro Compass
Issued 21 January 2010 Resolved
Gyrocompass is not operating properly and show a deviation of 30-40 degrees. Master failed to notify the cotp of non-operating equipment. Correct deviation of gyrocompass prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2010
Resolution: Deficiency Recttified by DMI. Vessel has a new Gyrocompass and operating properly.
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 21 January 2010 Resolved
Magnetic compass deviation table was last updated on 08oct2008. Ensure compass deviation table is accurate
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 February 2010
Resolution: The Captain prepare new Compass Deviation Table on February 09, 2010 and is keeping on the bridge.
Deck/Cargo › Ballast › Piping
Issued 21 January 2010 Resolved
The piping on the #6 ballast tank vent pipe in way of hydraulic equipment casing has holes and is wasted
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 February 2010
Resolution: All holed and wasted vent pipe was crop and renew for new pipe according and to satisfaction of RO Surveyor.
Deck/Cargo › Holds/Tanks › Cargo Tank Drainage
Issued 21 January 2010 Resolved
Starboard side deck drain piping is holed and wasted.This condition allows deck drain water to enter main cargo hold space.Permanent and proper repairs must be effected.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 February 2010
Resolution: All holed and wasted drain pipe was crop and renew for new pipe according and to satisfaction of RO Surveyor.
Documentation › Logs/Records › Oil Record Book
Issued 27 December 2009 Resolved
Oil record book was not being maintained in accordance with MARPOL 73/78, Annex I, regulation 17.2. Entries were inconsistent when compared receipts for disposal of sludge to reception facilities. Anomalies include differences in amounts transferred, dates of operations and missing entries.
Due 27 December 2009
Resolved 27 December 2009
Resolution: Deficiency was cleared and a special note has been added to the Vessels Critical Profile to ensure that the Oil Record Book is thoroughly reviewed during subsequent inspections.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 27 December 2009 Resolved
The Form E attachment to the SOLAS Cargo Ship Safety Equipment Certificate was missing information. Flag State representative must provide an updated Form E attachment that includes the total number of persons allowed for the lifesaving appliances onboard and the endorsement for the LRITtransmission requirements in accordance with MSC.1/Circ. 1307.
Action required: 705 - Other - as specified
Due 4 January 2010
Resolved 23 January 2010
Resolution: Coast guard check the Form E and meets the satisfaction of the coast guard.
Navigation › Piloting/Steering › Gyro Compass
Issued 27 December 2009 Resolved
Gyrocompass was not operating properly and was showing a variance of 30 to 40 degrees. Master reported the inoperable equipment to the Owner and the local agent prior to entry into the Port of New York but no letter of deviation was requested in accordance with 33 CFR 164.53 for inbound transit. Make necessary repairs to the gyrocompass and submit a technicians report prior to next U.S. port.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 December 2009
Resolved 26 January 2010
Resolution: Deficiency Rectified by the DMI.
Engineering › Lubricating Oil Service System › Purifier
Issued 27 December 2009 Resolved
There was a leak observed on the supply line from the diesel oil tank to the diesel oil purifier that was creating a collection of diesel oil within the containment sorrounding the purifier and into the bilge below. Arrest leak and properly clean spilled diesel oil to the satisfaction of a Flag State representative prior to return to U. S. waters.
Action required: 705 - Other - as specified
Due 4 January 2010
Resolved 23 January 2010
Resolution: Deficiency Rectified.
Engineering › Steering Gear System › Power Unit
Issued 27 December 2009 Resolved
Steering controls for the emergency steering gear were not in an accessible location to be safely operated by the crew. In order to access both steering control stations, the crew must climb over piping and side longs and even then, do not have any firm footing while engaging the steering controls. Flag State representative to determine the suitabilty of the current arrangement.
Action required: 705 - Other - as specified
Due 4 January 2010
Resolved 22 January 2010
Resolution: Deficiency Rectified
Construction/Loadline › Structures › Door
Issued 27 December 2009 Resolved
Observed evidence of a leak in the hydraulic control system located on the main cargo deck, port side control station for the cargo ramp. There was hydraulic fluid that accumulated and collected in the containment area around the controls. Determine the source of the hydraulic leak, make the necessary repairs, remove and clean spilled hydraulic oil prior to return to U. S. Waters.
Action required: 705 - Other - as specified
Due 4 January 2010
Resolved 24 February 2010
Resolution: The oil cooler do not have a problem, it is in serviceable condition. All cooler pipe and fitting holed and wasted were crop and renew according and to the satisfaction of the RO Surveyor.
Engineering › Bilge Water Management System › Pump
Issued 27 December 2009 Resolved
Vessel exhibits excessive sea water leaking from the ballast pump shaft packing gland when the fire/bilge pump is in operation. Make necessary repairs to arrest the leak on the ballast pump packing gland prior to return to U. S. waters.
Action required: 705 - Other - as specified
Due 4 January 2010
Resolved 23 January 2010
Resolution: Deficiency Rectified.
Engineering › Bilge Water Management System › Pump
Issued 17 December 2009 Resolved
1440 Vessel exhibits excessive sea water leakage from ballast pump shaft packing gland when fire/bilge pump is energized. Vessel must make repairs to Ballast pump packing gland. 33 CFR 160.113(a) SOLAS 60 Reg 11 to satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2009
Resolved 22 December 2009
Resolution: Class survey report attested to repair. PSC Examiners witnessed proper operation.
Engineering › Fuel Oil Service System › Piping
Issued 17 December 2009 Resolved
1410 Fuel injector lines on stbd MDE are cracked and improperly repaired. Vessel to replace or repair injector lines to the satisfaction of attending class surveyor. 33 CFR 160.113(a) SOLAS 60 reg 11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2009
Resolution: Class report states that the repairs to the fuel injector lines are adequate. CG PSC Examiners witnessed operation of engine with no leakage from lines.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 17 December 2009 Resolved
1550 Ship is required to have an operable ship's whistle. Vessel's crew took 45 minutes to operate whistle while underway. COLREGS Rule 33 to satisfaction of class & CG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2009
Resolution: Class report attested to repair. CG PSC Examiners witnessed test of ship''e whistle.
Fire Fighting › Nozzles › Type
Issued 17 December 2009 Resolved
Vessel has 'jet only' type nozzles at some hydrants. Vessel to provide dual-purpose nozzle for each hose. SOLAS 60 II/65(c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 January 2010
Resolution: Deficiency Rectified.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 17 December 2009 Resolved
1720 Vessel has excessive oil in engine room bilges. Vessel must remove excess oil. 33 CFR 160.113(a) SOLAS 60 reg 11 to satisfaction of class and Coast Guard
Due 4 January 2010
Resolved 23 January 2010
Resolution: Deficiency Rectified
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 17 December 2009 Resolved
0110 Vessel's record of equipment for the safety equipment certificate, issued after the LRIT conformance test report, is not endorsed with LRIT transmission requirements in accordance with MSC.1/Circ. 1307. SOLAS Cons 2004 Reg V/19.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 January 2010
Resolution: Deficiency Rectified.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 17 December 2009 Resolved
0660 Six (6) life jackets light not operational. All life-saving appliances shall be in working order and ready for immediate use. SOLAS 74/78 Ch. III reg 20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2009
Resolution: 6 new CG approved life jacket lights were on board.
Lifesaving › Lifeboat Equipment › Electric Torch
Issued 17 December 2009 Resolved
0611 Lifeboat fuel for kerosene lamp on lifeboat is stored in water bottles. Store fuel in appropriate container. SOLAS 74 (Amended) Ch. III reg 13
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 December 2009
Resolution: Kerosene is stored in metal containers.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 17 December 2009 Resolved
1410 Stbd MDE #'s 1,6, and 8 cylilnder's pyro meters are inoperable. Repair or replace all non-working pyro meters. SOLAS 65 Reg 11
Action required: 705 - Other - as specified
Due 29 December 2009
Resolved 23 January 2010
Resolution: Deficiency Rectified.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 16 December 2009 Resolved
0220 Vessel does not meet Minimum Safe Manning Certificate. Chief mate does not have a valid Panamanian Flag Endorsement to National License, nor an accepted application for endorsement on file. STCW 95 I/4, STCW 95 1/14-1, SOLAS 74/78 V/14
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2009
Resolved 22 December 2009
Resolution: A new chief officer with proper credentials is onboard.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 December 2009 Resolved
1730 OWS MEPC 107.49 does not have a valid calibration certificate on board. Provide calibration certificate. MARPOL 74/78 Annex I reg 14 to satisfaction of class and Coast Guard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 January 2010
Resolution: Deficiency Rectified.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 December 2009 Resolved
1730 OWS throughput is not provided on the supplement to the IOPP Certificate. MARPOL 74/78 Annex I reg 14
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 January 2010
Resolution: Deficiency Rectified.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 16 December 2009 Resolved
1410 Vessel's maneuverability is reduced. Vessel lost propulsion on the starboard main engine while heading toward Charleston "C" buoy. Engine to be repaired to the satisfaction of class. SOLAS 60 Reg 11, 33 CFR 160.113(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2009
Resolved 22 December 2009
Resolution: Vessel Made repairs to the stbd engine. The vessel entered the port of Charleston on both engines. Class Surveyors attended the vessel and issued report attesting to repairs. CG PSC Examiners witnessed engine in operation.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 16 December 2009 Resolved
2120 Vessel has two entries in the garbage record book. October 5th and 14th, 2009. For category "1" and "other" Garbage discharged to reception facilities. No reciepts are provided for the discharges. Recommend company review Garbage Management Plan and Garbage Log. MARPOL 73/38 Annex V Reg 9
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 January 2010
Resolution: Meets the satisfaction of the coast guard
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 28 April 2009 Resolved
Vessel removed two inflatable life rafts from service. Vessel is only required to have 2 life rafts and two life boats. Cargo Ship Safety Equipment Certificate must be amended by DNV to reflect the proper number of life rafts onboard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2009
Resolution: Received class report stating that Ship Safety Equipment Certificate has been amended to reflect proper number of life rafts onboard.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 28 April 2009 Resolved
Vessel has two missing propeller blades on the port side. DNV required the Chief Engineer to report after 3 months on the condition of the CPP equipment. Chief Engineer and Master failed to send this required report to DNV. Vessel must submit this report and DNV must provide verification to Sector NY prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2009
Resolution: DNV provided a report that they received their required statement from the Chief Engineer and are happy with the way the machinery is holding up. [name withheld]
Engineering › Fuel Oil Service System › Filter
Issued 28 April 2009 Resolved
The Emergency Diesel Generator's duplex fuel strainer/filter is leaking causing a potential fire hazard. Vessel must have seals replaced to the satisfaction of the attending classification surveyor.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2009
Resolution: Received class report stating that washer has been changed out and leaks have been stopped.
Engineering › Steering Gear System › Pump
Issued 28 April 2009 Resolved
The #1 hydraulic pump and actuator to the emergency steering gear is leaking hydraulic fluid. This loss of hydraulic oil may eventually cause the equipment to fail. Vessel must have this equipment repaired to the satisfaction of the attending classification surveyor.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2009
Resolution: Received class report stating that repairs have been made to minimize leakage.
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 23 March 2009 Resolved
Switchboard for ship's emergency generator is not adequate due to inadequate sized non conductive matting. Provide statement from Master attesting to proper installation of matting. To the satisfaction of the Coast Guard. 74 SOLAS 2004 (consolidated) II-I Reg 45 (2).
Condition: Improper Installation
Due 30 March 2009
Resolved 4 April 2009
Resolution: Received class report stating that non conductive matting was installed in the switchboard for ship''s emergency generator room.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 23 March 2009 Resolved
Oily water separator equipment missing "DISCHARGE OF OIL PROHIBITED" placard. No other placard observed throughout machinery spaces. Provide statement from Master attesting to proper installation of placard. Deficiency rectified to satisfaction of Coast Guard. 33 CFR 155.450.450
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 23 March 2009
Resolution: Placard installed.
Construction/Loadline › Penetrations › Gasket
Issued 23 March 2009 Resolved
Means of maintaining weather tightness on cargo lift operating from weather deck to main deck is compromised due to deteriorated gaskets. This causes water to penetrate through lift. Vessel shall repair to the satisfaction of Administration. ICLL 66 Annex I REG/6.4.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2009
Resolved 31 March 2009
Resolution: Received class report stating that new gaskets were fitted.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 March 2009 Resolved
Air compressors in engine room do not provide adequate protection to crew due to missing fan guards; this creates a safety hazard. Install guards to the satisfaction of Administration. 74 SOLAS (2004 Consolidated) II-I Reg 26.1
Condition: Improper Installation
Due 30 March 2009
Resolved 4 April 2009
Resolution: Received class report stating that metal guards were fitted.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 5 March 2009 Resolved
Vessel has decreased maneuverability due to an inoperable bow thruster and a propeller missing blades. Provide a class report regarding these two deficiencies prior to next U.S. port.
Action required: 15 - Rectify deficiencies by next port
Due 5 March 2009
Resolved 6 March 2009
Resolution: Received Class report attesting to the satisfactory operation of damaged propeller. A condition of Class has been imposed until 20 June 2009.
Engineering › Steering Gear System › Helix Shaft
Issued 20 January 2009 Resolved
#1 Steering gear pump shaft seal continuously leaking hydraulic fluid. To be corrected to the satisfaction of Class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 January 2009
Resolution: Steering gear pump #1 shaft seal has been repaired and has been satisfactorily tested as per report by DNV Surveyor dated 23 January 2009. Def Cleared.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 January 2009 Resolved
Audible alarm on OWS system is non operational. To be corrected to the satisfaction of Class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 January 2009
Resolution: Alarm has been repaired, tested, and found in working order as per DNV Surveyor report dated 23Jan09. Def cleared
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 28 December 2008 Resolved
Portable fire extinguishers in engine room need to be mounted in a way to not become a hazard from falling out of brackets
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 January 2009
Resolved 27 January 2009
Resolution: Portable fire extinguisher in enginerooms were found to be properly secured by head support and straps as per report from DNV Class Surveyor. Def Cleared
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 16 July 2008 Resolved
Provide class attestation of the proper operation of the MSD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 24 September 2008
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 16 July 2008 Resolved
Provide report attesting to the correction of all deficiencies previously issued by the Coast Guard.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2008
Resolved 11 October 2008
Resolution: All defs rectified.
Construction/Loadline › Structures › Door
Issued 26 June 2008 Resolved
PROVE WEATHER TIGHTNESS OF ELEVATOR HATCH IN SAILING CONDITIONS. TO THE SATISFACTION OF CLASS.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 September 2008
Deck/Cargo › Cargo Stowage › General
Issued 26 June 2008 Resolved
HYDRAULIC PUMP SYSTEM FOR MAIN CARGO ELEVATOR LEAKING HYDRAULIC OIL.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 July 2008
Resolved 11 October 2008
Resolution: Provided DNV Survey report attesting to the leaking of hydraulic oil. Vessel also cleaned up whatever hydraulic oil was on the deck.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 June 2008 Resolved
HYDRAULIC OIL ON DECK IN CARGO ELEVATOR PUMP RM. CAUSING SLIP AND POSSIBLE FIRE HAZARD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2008
Resolution: CREW CLEANED AND REMOVED THE OIL ON DECK.
Fire Fighting › Fire Hoses › Connections
Issued 26 June 2008 Resolved
SEVERAL FIRE HOSES ON BOARD HAVE MISSING OR WAISTED GASKETS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2008
Resolution: GASKETS WERE REPACED OR CHANGED.
Lifesaving › Lifebuoys › Size
Issued 26 June 2008 Resolved
LIFE BOUYS INTENDED TO OPERATE THE QUICK RELEASE ARRANGEMENTS FOR THE SELF ACTIVATED SMOKE SIGNALS ARE OF INSUFICIANT WIEGHT.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2008
Resolution: received recite that the ship purchased two new lifebuoys and was placing into service.
Lifesaving › Lifebuoys › Serviceable
Issued 26 June 2008 Resolved
LIFEBOUYS LOCATED ON BRIDGE WINGS ARE NOT CAPABLE OF QUICK RELEASE FOR SELF ACTIVATING SMOKE SIGNALS. TO THE SATISFACTION OF CLASS AND THE COAST GUARD.
Due 10 July 2008
Resolved 11 October 2008
Resolution: Provided DNV Survey report attesting to the proper operation of the quick release smoke lifebouys.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 26 June 2008 Resolved
JACKET WATER LEAK ON STARBOARD MDE ON #3, 8, AND 9 HEADS.
Action required: 705 - Other - as specified
Due 26 July 2008
Resolved 26 July 2008
Resolution: RECIEVED CLASS REPORT THAT THE LEAKS WERE CORRECTED.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 6 June 2008 Resolved
Vsl crew failed to perform required paralleling procedures of the #1 & #2 SS generators prior to entering port as per the Safety Management Plan ultimately leading to a loss of power and steering during entry into the Port of Hampton Roads. Vsl required to conduct an internal audit of the ISM prior to next US port after sailing foreign.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 October 2008
Resolution: Provided DNV Class report on proper operations of the SSDG #1 and #2.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 6 June 2008 Resolved
Vsl failed to conduct a test of the emergency generator prior to entry into US waters. Emergency generator was left in the "manual" start mode and due to the vsl loosing power because of an associated electrical problem, the emergency generator did not start.
Due 6 June 2008
Resolved 6 June 2008
Resolution: The nature of the deficiency was human error and was corrected on the spot.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 6 June 2008 Resolved
Vsl does not have a bell or gong for sounding the appropriate signals for restricted visibility.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 October 2008
Resolution: Vessel installed bell for restricted visibility.
Documentation › Certificates/Documents › IOPP Certificate
Issued 3 June 2008 Resolved
IOPP form A does not contain the maximum throughput number for the oily water separator. DNV must provide the appropriate throughput number on the certificate.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 October 2008
Resolution: DNV updated IOPP Form A with the maximum throughput.
Fire Fighting › Fire Hoses › Material
Issued 3 June 2008 Resolved
Make permanent repair/replace two fire hose boxes. Fire hose boxes were cracked and unable to secure the hoses.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 July 2008
Resolved 11 October 2008
Resolution: All fire boxes locking clips were replaced and were found satisfactory.
Fire Fighting › Fire Main › Condition
Issued 3 June 2008 Resolved
Make permanent repairs / replace gauges on #1 main fire pump to satisfaction of Class.
Action required: 705 - Other - as specified
Due 3 July 2008
Resolved 11 October 2008
Resolution: Provided DNV Survey report on repairs/replacing of gauges.
Lifesaving › Inflatable Liferafts › Painter
Issued 15 February 2008 Resolved
Inflatable liferaft painter was not attached to ship or weaklink, not allowing for life raft to inflate after being automatically released.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2008
Resolved 15 February 2008
Resolution: Rectified on the spot.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 15 February 2008 Resolved
major fuel oil leak on #2 diesel generator fuel pump. Excesive fuel around base of generator and drippnig into bilge causing hazard to ship and crew. Require class to atest to repairs of generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2008
Resolution: Recieved class report from class survey on the efected repairs of generator fuel pump.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 11 February 2008 Resolved
Controllable pitch propulsion (CPP) port not able to go to 100+/- degrees and is slow to respond. Chief Engineer stated that the system was frozen due to the extreme cold. Prior to departure demonstrate proper operation of CPP to Class. Class (DNV) attended vessel and issue condition to have repaired by March 31, 2008 CPP still slow to respond.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 11 March 2008
Resolution: Went onboard vessel to conduct a vissual inspection, test the sistem and received class report stating that deficiency is corrected.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 11 February 2008 Resolved
During the review of the Devon Shipping Safety Management Plan, DOC SMM 3.3 page 13/17, Chief E is required to make monthly reports. Chief E is not able to produce proof that monthly reports are being sent to management. In addition the only monthly reports available are for Oct, Nov and Dec 2007, but they were never sent to managers. Prior to departure the RO to conduct a audit.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2008
Resolved 13 February 2008
Resolution: Audit discovered 9 additional nonconformities.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 February 2008 Resolved
Repair inop (emergency) deck light, 02 aft deck fixtures fwd on house
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 February 2008
Resolved 11 March 2008
Resolution: Went onboard vessel to conduct a vissual inspection and received class report stating that deficiency is corrected.
Engineering › Diesel Engine (auxiliary) › Block
Issued 8 February 2008 Resolved
Replace weaken bulging flex hose INO #1 Generator
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 February 2008
Resolved 11 March 2008
Resolution: Went onboard vessel to conduct a vissual inspection and received class report stating that generators are tobe overhauled and deficiency is to be corrected at the next dry dock.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 8 February 2008 Resolved
Renew soft patch piping INO Seawater cooling for port M/E (02 patches)
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 February 2008
Resolved 11 March 2008
Resolution: Went onboard vessel to conduct a vissual inspection and received class report stating that deficiency is to be corrected at the next dry dock.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 8 February 2008 Resolved
Provide for updated Notice of Arrival for all mistakes USCG has pointed out. 33CFR160
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2008
Resolved 13 February 2008
Lifesaving › Inflatable Liferafts › Approval
Issued 27 December 2007 Resolved
Life rafts were in cargo hold and not on station during the exam. Captain informed Boarding team that new rafts were not fit for existing brackets on vessel, and will rectify to class satisfaction prior to departure from COTP Zone.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 January 2008
Resolution: The vessel relocated the brackets to accommodate for the larger size life rafts. Received a class report for the new installation and adjustment for the handrails.
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 1 December 2007 Resolved
Vessel had no Transfer Procedures onboard for use with bunkering/lightering of fuel oil, bilge slops, ect.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 February 2008
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 29 November 2007 Resolved
The galley does not have adequate storage for refridgerated provisions. Prior to next US port after sailing foreign prove adequate storage for refridgerated items.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 February 2008
Resolution: Attended vessel and visually inspected new refrigerated stores.
Accommodation/Occupational Safety › Messroom › Location
Issued 29 November 2007 Resolved
Garbage in galley not properly separated. Plastics are with food, cans, and paper. Properly seperate garbage prior to next US port after sailing foreign.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 February 2008
Resolution: Attended vessel and visually verified separated trash.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 November 2007 Resolved
Starboard side self-igniting light not working. Replace light prior to next US port after sailing foreign.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 29 November 2007
Resolution: Recieved new self-igniting light prior to completion of PSC exam.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 29 November 2007 Resolved
Excess paint stored in the engine room. Properly store all paint in the paint locker prior to next us port after sailing foreign.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 February 2008
Resolution: Attended vessel, paint removed and stowed properly.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 29 November 2007 Resolved
Crew attempted to test smoke detector in the engine room by blowing smoke from a cigarette into the detector. Obtain testing smoke to properly test detectors. To the satisfaction of Class.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 December 2007
Resolution: Attended vessel and witnessed satisfactory gas smoke alarm detector.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 November 2007 Resolved
Medical locker contained several expired medicines. Replace expired medicine prior to next US port after sailing foreign.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 February 2008
Resolution: Attended vessel and inspected many medicines and found all within experation date.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 November 2007 Resolved
On the trailer deck at Frame # 9 the light is missing a cover. Replace/Provide replacement cover for light. To the satisfaction of Class.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 February 2008
Resolution: Attended vessel and visually inspected new light cover.
Fire Fighting › Structural - Horizontal Zones › General
Issued 29 November 2007 Resolved
Drain lines forward on the Car/Trailer deck had several soft patches and was made of plastic. Class to verify permanent repairs to line and approve current arrangements.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 February 2008
Resolution: Attended vessel and visually inspected new drain piping.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 November 2007 Resolved
Found 02 lights located in the inner bottom deck without proper covers. Replace current covers on lights. Prior to next US port after sailing foreign.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 February 2008
Resolution: Attended vessel and visually inspected new light covers,
Fire Fighting › Self-contained Breathing Apparatus › Air Supply (minutes)
Issued 29 November 2007 Resolved
EEBD located on emergency exit in engine room is empty. Replace prior to next US port after sailing foreign.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 February 2008
Resolution: Attended vessel and visually inspected new EEBD located in engine room.
Deck/Cargo › Cargo Stowage › General
Issued 29 November 2007 Resolved
Prior to departure the vessel's flag administration must verify that all cargo is "properly secured" flag currently on board and will fax report before the vessel leaves the port.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2007
Resolved 29 November 2007
Resolution: Received report from Flag Admin that Cargo was properly secured. Def cleared.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 November 2007 Resolved
Plug exposed outside the entry to accomodation spaces on portside weather deck, replace cover. Prior to next US port after sailing foreign.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 9 February 2008
Resolution: Attended vessel and visually inspected new plug cover.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 November 2007 Resolved
REFRIDGERATION ELECTRICAL BOX STBD SIDE (ON TRAILER DECK) - COVER BROKEN
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 November 2007
Resolution: Attended vessel and cleared said deficieny by visual confirmation.
Construction/Loadline › Markings › Load Line Mark
Issued 6 November 2007 Resolved
LOAD LINE MARK NOT PAINTED IN CONTRASTING COLOR.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 November 2007
Resolution: Attended vessel and cleared said deficiency by visual confirmation.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 6 November 2007 Resolved
DRAFT MARKS NOT VISIBLE ON BOW.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 November 2007
Resolution: Attended vessel and cleared said deficiency by visual confirmation.
Construction/Loadline › Penetrations › Weld
Issued 6 November 2007 Resolved
NON WEATHER-TIGHT WIRE PENETRATION ON PORT SIDE SUPERSTRUCTURE, TRAILER DECK.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 November 2007
Resolution: Attended vessel and cleared said deficiency by visual confirmation.
Deck/Cargo › Cargo Stowage › General
Issued 16 October 2007 Resolved
Found wheel-based cargo stowed on inner bottom cargo deck that was loaded in Boston not secured in accordance with the Cargo Securing Manual Annex 4. "Prior to departing the next US port, the Administration must approve the stowage of all cargo", while the Cargo Securing Manual is being reviewed by the vessel’s new Classification Society (DNV).
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2007
Resolved 5 November 2007
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 16 October 2007 Resolved
Vessel submitted a Notice of Arrival with incorrect information. Two of the five previous ports were listed with wrong arrival & departure dates, an Oiler's Passport Number was wrong, and another Oiler's date of birth was incorrect. Prior to departure update vessel's NOA to reflect correct information.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2007
Resolved 16 October 2007
Resolution: Phone call made to NVMC all information has been updated and modified to reflect the correct information.
Fire Fighting › Fire Hydrants › Location/Position
Issued 16 October 2007 Resolved
On the Trailer deck in way of Frame 20, both Port & Starboard Fire Mains & Hydrants were completely blocked. In particular the Port Fire Main was blocked by multiple lube oil barrels and a bushel of mulch, and the starboard Fire Main by misc. cargo gear. Prior to conducting Cargo Operations clear all obstacles to swiftly extinguish fire in case of emergency.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2007
Resolved 16 October 2007
Resolution: Cleared while onboard.
Fire Fighting › Fire Hydrants › Condition
Issued 16 October 2007 Resolved
Fire main in Engine room has rubber patch on pipe. Patch is forward end starboard side in way of frame 25. Repair prior to return to US to satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Due 16 October 2007
Resolved 5 November 2007
Resolution: Temp. Repair approved by Class.
Deck/Cargo › Cargo Stowage › General
Issued 16 October 2007 Resolved
Cargo Securing Point, Trailer Deck in way of Frame 20 is holed and is packed with cloth material. Securing point is located over Starboard Main Engine forward end repair prior to return to US to satisfaction of Class.
Action required: 15 - Rectify deficiencies by next port
Due 16 October 2007
Resolved 5 November 2007
Resolution: Temp. repair approved by Class.
Lifesaving › Lifeboat › Lamp (inside)
Issued 7 October 2007 Resolved
Starboard lifeboat equipment is completely saturated with water. Inoperable searchlight and fish equipment also found on the lifeboat. Some of the packaged food was found in damaged packaging. Port side lifeboat was occupied by 02 stowaways. Some of the food on the port side lifeboat was eaten by the stowaways. The rest of the food wasn't vacuum sealed. Unsanitary conditions were found.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2007
Resolution: Lifeboats were cleaned and the required items found on board.
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 7 October 2007 Resolved
Primary generator has excessive knocking noise and appears to have a small water leak on the rear starboard side head.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2007
Resolution: Resolved to class satisfaction.
Construction/Loadline › Structures › Manhole
Issued 7 October 2007 Resolved
Hatch cover on main deck forward of the collision bulkhead has a bad gasket/seal and knife edge is wasted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2007
Resolution: Resolved to class satisfaction.
Construction/Loadline › Structures › Deck Plating
Issued 7 October 2007 Resolved
Port side ladder leading from the main deck to the house has a few wasted/rusted stair treads that need replacing. Starboard side ladder directly opposite of this ladder is showing early signs of the same.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2007
Resolution: Resolved to class satisfaction.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 7 October 2007 Resolved
The head had an inoperable toilet on the starboard side. The toilet area was also being used as a shower. Urine and fecal matter were found on the deck of the shower as well.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2007
Resolution: Resolved to Coast Guard satisfaction.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 October 2007 Resolved
Galley deck, cabinet spaces, and closet spaces are infested with insects. Pockets of dirty water and garbage were found in the corners of the galley. Grease trap was extremely clogged with grease.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2007
Resolution: Resolved to Coast Guard satisfaction.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 October 2007 Resolved
Port side deck 2 by potable water tank has wastage around electrical wire stuffing tubes & where bulkhead & deck meet.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2007
Resolution: Resolved to class satisfaction.
Construction/Loadline › Structures › Air Pipe
Issued 7 October 2007 Resolved
Leakage on port side drain pipe in the forward most part of the lower garage.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2007
Resolution: Resolved to class satisfaction.

Ownership record