Records from 2008 to 2023. Most recent: inspection, 9 May 2023.
Inspection history · 23
9 May 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7688604
21 July 2022
Administrative Inspection · Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7512887
9 February 2021
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7138036
17 March 2020
Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6928588
30 January 2020
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6899625
21 March 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6648672
20 February 2018
COI Inspection · Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6358101
15 June 2017
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6176695
14 March 2017
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6105357
27 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5863890
9 February 2016
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5812666
31 March 2015
Examination of Repairs · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5093866
4 March 2015
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5078436
13 February 2015
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5071738
13 February 2015
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5073142
18 February 2014
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4801503
11 May 2012
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4311151
12 October 2011
Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4166654
2 August 2011
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4104334
13 July 2011
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4079113
16 April 2010
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3714951
7 April 2009
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3448070
26 June 2008
Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · Hull Examination · MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3248320
04 - Emergency Systems › N/A - No Subsystem › Shipboard Marine Pollution emergency operations
Issued 21 March 2019
Resolved
A tank vessel with the capacity of 250 or more barrels that is carrying oil or hazardous materials as cargo must have an emergency means to stop the flow of cargo. During annual inspection the prime mover for the cargo pump would not start in order to inspect the emergency shutdown as prescribed above and prime mover for hazards. Prior to conducting discharge of cargo prove proper operation of the emergency shutdown while prime mover is operating to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 703 - Prior to bunkering operations
Resolved 26 March 2019
Resolution: Received satisfactory information that the emergency shutdown is opperational.
Construction/Loadline › Hull › Side Shell
Issued 13 February 2015
Resolved
There is an approx 14' x 10' x 4" inset with internal framing/bulkhead damage in the stbd voids number 1 and 2. Must make permanent repairs to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2015
Resolution: Visually examined and pneumatically tested the following:
1) 3'' x 9'' x 1/2" deck knuckle insert in #1 stbd void.
2) 2''6" x 9'' x 1/2" side plate insert in #1 stbd void.
3) 5''6" x 6''6" x 3/4" bilge knuckle insert in #1 stbd void.
4) 5'' x 7'' x