Inspection history · 61
11 February 2026
Vessel Attendance · Examination of Repairs · Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8308750
17 January 2026
Vessel Attendance · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8298079
27 September 2025
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8243013
27 September 2025
Damage Survey
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8243530
22 September 2025
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8239602
10 July 2025
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8157811
17 March 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8095178
17 March 2025
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8183182
9 August 2024
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7977936
29 July 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7969999
27 June 2024
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7989379
23 May 2024
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7918057
5 October 2023
Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7804335
27 September 2023
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7800532
26 September 2023
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7800158
11 May 2023
Deficiency Check · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7686017
11 May 2023
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7694052
6 January 2023
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7617436
20 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7434875
7 December 2021
Deficiency Check · Initial Certification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7363895
17 November 2020
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7098038
20 July 2020
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7011133
10 December 2019
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6871371
1 October 2018
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6570295
11 October 2017
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6294940
6 March 2017
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6099554
23 February 2017
Type not recorded
No type recorded · Station Port OConnor · USCG Heartland District (CGD-H) · Activity 6093832
4 November 2015
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5762346
8 October 2015
Uninspected Other
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5737553
8 June 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4337381
18 February 2008
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3149975
15 April 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2911109
26 March 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2609772
18 May 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2359011
18 April 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2337062
8 April 2005
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2329400
14 November 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2250018
10 April 2004
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2100566
25 November 2003
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1986788
28 October 2003
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1959504
23 September 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1911379
13 August 2003
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1876292
27 February 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1755657
22 February 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1728512
24 April 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 766169
17 April 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 196450
1 November 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 141625
16 October 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 109367
6 March 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 766173
3 March 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 206632
27 February 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 151572
6 February 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 116983
23 November 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 435127
23 November 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 435190
5 September 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 66226
2 April 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 109298
25 March 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 65950
20 October 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 27016
6 October 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 99672
6 October 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 116941
19 July 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 163909
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
The starboard generator is out-of-service and the port generator failed.
Make proper repairs to the generators to prove proper operation to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 19 March 2026
Resolution: MI conducted an operational test of both generators. MI observed crew shifting from shore power to ship power, each generator was capable of maining the electrial load during the test. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2026
Resolved
Repairs and minor alterations to existing towing vessels must be made in accordance with this part. New installations that are not replacements in kind must comply with the requirements of subpart C of this part.
An aux temporary generator was placed on the bow of the vessel. Removal of aux generator prior to departure.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2026
Resolution: The aux generator was removed from the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 January 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Identified significant coolant leak on starboard main engine. Repair to the satisfaction of the attending USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 19 March 2026
Resolution: MI conducted an operational test of the starboard main engine, no leaks observed. All sat.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 29 January 2026
Resolved
The owner or managing operator of an existing vessel not operating under a stability document must be able to show at least one of the following: The vessel performs successfully on operational tests to determine whether the vessel has adequate stability and handling characteristics.
Vessel stability is questioned due to persistent starboard list and excessive stern trim when potable water tanks are filled. Vessel must successfully perform an operational test to the satisfaction of the attending MI to ensure satisfactory vessel stability.
A one-time deadship tow transit with assist vessel ITV Raymond (O.N. 997329) from Seadrift, TX City Dock to mile marker 534 of the ICW Homeport of AG Marine Inc. in Ingleside, TX is permitted during daylight hours only, on 30 Jan 2026, in accordance with the submitted transit plan. Any deviation to the plan during the transit shall be reported to the nearest OCMI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 20 March 2026
Resolution: Conducted underway sea trial test at full speed with hard over P&S movement. Freeing port water shedding is adequate. Vessel still has a slight starboard list which will be assessed at next DD.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 January 2026
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable.
Bilge had excessive oily water accumulation of approx. 4-5" in the engine room bilge and the bilge alarm was activated due to oily water level.
Removal of oily water from bilge to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 29 January 2026
Resolution: Vessel hired company to remove oily bilge water.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 January 2026
Resolved
Decks and bulkheads designed to be watertight or weather tight must be maintained in that condition.
The hydraulic cable line penetrating through the stern to engine room bulkhead was leaking water into the engine room with the stern void flooded. Temp repairs made. Additionally, There is a hole cut out in the port ceiling weather deck of the engine room. Permanent repairs are to be made to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 19 March 2026
Resolution: Vessel sealed cable penetration with 5200 as a temp repair. Will make permant repair for upcoming 2026 drydock.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 January 2026
Resolved
Decks and bulkheads designed to be watertight or weather tight must be maintained in that condition.
An approximately .5 inch hole was on the stern deck midship of the potable water tank. Permanent repairs are to be made to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 26 February 2026
Resolution: Insert complete and NDT; all sat.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 29 January 2026
Resolved
The owner or managing operator must notify the cognizant OCMI when the condition of the vessel, its equipment, systems, or operations, create an unsafe condition. Vessel knowingly operated for an unknown amount of time with multiple unauthorized vessel alterations and unsafe operational/stability criteria and did not report the condition to the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 19 March 2026
Resolution: Vessel operator is aware and will comply with part 4 IAW 46 CFR 140.900.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 29 January 2026
Resolved
Flammable and combustible products must not be stored in machinery spaces, unless they are stored in a suitable container that meets the requirements of § 142.225 of this subchapter.
Charcoal bag was stored on the upper deck of the engine room, excessive buckets of oil and oily rags were in the engine room posing a fire hazard. Remove fire hazards to
the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2026
Resolution: Crew removed all fire hazards.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 January 2026
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Identified missing lagging on exhaust piping of the starboard generator and an approximate 1 ft section of exhaust piping on the port side main engine. Install lagging to satisfaction of MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2026
Resolution: Exhaust lagging has been installed and or replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Identified exhaust gas leak coming from lower flange on the starboard main engine exhaust piping. Repair exhaust gas leak to satisfaction of MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2026
Resolution: MI conducted operation test on starboard main engine, crew replaced gasket. No exhaust gas leak noted during operation test.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 29 January 2026
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail.
The starboard generator was missing guards on the gears and rotating machinery. Provide proper guard to rotating machinery to the satisfaction of the attending MI.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2026
Resolution: Guards have been installed, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 January 2026
Resolved
Electrical systems and equipment must function properly
and minimize system failures and fire and shock hazards.
Electrical hazards were observed throughout the engine
room. Make proper repairs to the satisfaction of the
attending MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2026
Resolution: MI observed electricl repairs thoughout the engine room to be satisfactory. Vessel properly supported all wire runs, closed off open stuffing tubes, and replaced covers on open junction boxes. No exposed wiring is remaing.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 January 2026
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly.
The starboard stern hatch is missing a dog and pin. Make repairs the the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2026
Resolution: Vessel made repairs to starboard hatch. Hatch will be replaced for upcoming 2026 drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 September 2025
Resolved
3-6 inch cracks were identified on 03 blades of the starboard propeller. Due to the extent of the damage, vessel is being asked to repair or replace the damaged propellor.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2025
Resolved 30 October 2025
Resolution: Vessel completed satisfactory repairs and successful sea trail was conducted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 July 2025
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. After loss of ships power, fire detection control panel is inoperable.
46 CFR 142.330(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 July 2025
Resolution: Capacitor was replaced in the panel; conducted sat test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 July 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel lost power during towing operations on the port generator for an unknown reason.
46 CFR 143.205(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 July 2025
Resolution: Lydia Ann techs made satisfactory repairs.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 18 July 2025
Resolved
Marine employers must establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels who: occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection; perform the duties and functions of patrolmen or watchmen required by this chapter; or are specifically assigned the duties of warning, mustering. assembling, assisting, or controlling the movement of passengers during emergencies. Operator does not have a program established or adequate records kept for crew
members in accordance with the regulations.
46 CFR 16.230(a)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 August 2025
Resolution: Received satisfactory DAPI program and proof of initial testing on employees.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 July 2025
Resolved
All fire hoses must be inspected for excessive wear, and subjected to a test pressure equivalent to the maximum service pressure. Port fire hose is leaking at the hydrant coupling.
46 CFR 142.240(a)(7)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 July 2025
Resolution: Fire hose has been replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 July 2025
Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Forward weather deck bulkhead in void below bridge is holed directly above a breaker panel.
46 CFR 143.400 (f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 29 July 2025
Resolution: Bulkhead was made weather tight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 July 2025
Resolved
Alarm set points for the main and auxiliary engine lubricating oil pressure and engine cooling water temperature requiring testing at a frequency of twice every 5 years, with no more than 3 years elapsing since last test. Vessel does not have any records of any such testing being completed.
46 CFR 143.245(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 12 August 2025
Resolution: LAC techs completed the test and replaced all high temp sensors on all M/Es and generators.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2025
Resolved
Pressure vessel relief valves require testing twice every 5 years with no more than 3 years elapsing since last test. Vessel does not have any records of such testing being completed.
46 CFR 143.245(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 25 August 2025
Resolution: Vessel purchased and installed new safety relief valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2025
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. Both main engines,
and port generator have exposed high temp piping.
46 CFR 144.830
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 25 August 2025
Resolution: Vessel purchased and installed new lagging.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 July 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Identified significant coolant leaks on both Port and Starboard main engines.
46 CFR 143.205(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 July 2025
Resolution: Lydia Ann techs repaired seals; all sat.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 18 July 2025
Resolved
Means must be provided to ensure that windows immediately forward of the operating station in the pilothouse allow for adequate visibility to ensure safe navigation regardless of weather conditions. Vessel does not have a functioning windshield wiper at the operating station.
46 CFR 144.905(b)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 July 2025
Resolution: New wiper installed and tested.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 July 2025
Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. Captain self-reported that the whistle had stopped working on the vessel on the last voyage.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 July 2025
Resolution: Ship whistle repaired and tested.
09 - Working and Living Conditions › 091 - Living Conditions › Sickbay
Issued 18 July 2025
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Identified multiple items in the first aid kit that are expired.
46 CFR 140.435
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 29 July 2025
Resolution: First aid kit replace in kind with new.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 July 2025
Resolved
All crewmembers must be provided with health and safety information and training that includes content and procedures of the owner or managing operator's health and safety plan. Crew is not familiar with the vessel’s health and safety plan.
46 CFR 140.515(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 25 August 2025
Resolution: New health and safety plan was developed and placed on board.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 July 2025
Resolved
Each towing vessel must comply with the requirements of part 4 of this chapter for reporting marine casualties and retaining voyage records. Vessel lost power for over 15 minutes while towing and fire detection control panel became inoperative. Crew did not report either to the Coast Guard.
46 CFR 140.900
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2025
Resolved 25 August 2025
Resolution: Captain has been briefed on the reporting procedures and they have also been incorporated into the vessel safety and health plan.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 July 2025
Resolved
Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition. Deck containment for bilge water over board is leaking into the E/R. Vessel is authorized a temporary concrete patch to be cropped and renewed to good steel at next DD.
46 CFR 140.610(f)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 August 2025
Resolution: Temporary concrete patch installed and notes entered for next DD.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Inspection team observed electrical cables not properly terminated above generators. 46 CFR 143.205(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 March 2026
Resolved 20 March 2025
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 17 March 2025
Resolved
Each towing vessel must be operated in compliance with: Applicable sections of the Federal Water Pollution Control Act.
Vessel was observed with substantial oily water in bilge due to shaft seal leak. Prior to movement the vessel shall remove all oily water from bilge. 140.655(a)
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 13 August 2025
Resolved 20 March 2025
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 March 2025
Resolved
Piping and machinery components that exceed 428 degrees fahrenheit including exhaust piping must be insulated.
Properly reattach exhaust manifold lagging to bother main engines. 46 CFR 143.220(b)
Action required: 705 - Other - as specified
Due 18 March 2026
Resolved 20 March 2025
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 17 March 2025
Resolved
An exposed hazard such as gears and rotating machinery must be protected by a cover, guard or rail.
Once repairs have been completed to engine shafts ensure machinery guards are in place and properly secured.
Action required: 705 - Other - as specified
Due 20 May 2026
Resolved 12 May 2025
Resolution: Received photos of machinery guard installation.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 August 2024
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: Be maintained to ensure proper operation.
Vessel was seen in dry dock with both props and starboard shaft pulled. Vessel rep was contacted and reported damage to both props and starboard shaft.
Vessel shall enact permanent repairs to the satisfaction
of the attending Coast Guard Marine Inspector prior to movement.
Prior to putting the vessel back in the water the Coast Guard Marine Inspector must inspect repairs. The vessel shall also conduct a sea trials with the Coast Guard Marine Inspector presence. 46 CFR 143.205 (c)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 August 2024
Resolution: Vessel made repairs, place vessel back in water. MI got underway to check for viberations and ensured vessel could make crusing speed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 11 June 2024
Resolved
Towing machinery such as capstans, winches, and other mechanical devices used to connect the towing vessel to the tow must be designed and installed to maximize control of the tow. The forward winches are not installed. Vessel limited to side or stern towing only. Rectify to the satisfaction of USCG marine inspector prior to pushing ahead.
Action required: 705 - Other - as specified
Resolved 20 June 2024
Resolution: Received email from vessel rep with pictures of both port and starboard forward towing winches installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2024
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light. The starboard side water light battery was expired and port side water light was missing. Replace to the satisfaction of USCG inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 13 June 2024
Resolution: Received email from vessel rep with pictures of both port and starboard life rings with lights and with both battery expiration dates on batteries.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Hot water tank is not secured.
Rectify to the satisfaction of USCG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 20 June 2024
Resolution: Received email from vessel rep with picture hot water tank secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. The electrical enclosure on the Starboard Side of the engine room had a high voltage wire that was not properly secured, the outer insulation was outside of the enclosure showing the insulation of the smaller wires. Rectify to the satisfaction of USCG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 20 June 2024
Resolution: Received email from vessel rep with picture of high voltage wire outer insulation properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2024
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. The wires for the generators and main engines batteries are secured using wing nut connections. Rectify to the satisfaction of USCG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 12 June 2024
Resolution: Received email from vessel rep with pictures of battery connections with adequate secure connections replacing wing nuts.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 June 2024
Resolved
The records of inspections and tests of fire-detection systems and fixed fire-extinguishing systems must be recorded in the TVR, official logbook, or in accordance with any TSMS applicable to the vessel. The following minimum information is required: receipts and other records generated by these inspections and tests must be retained for at least 1 year and made available upon request. The servicing information was not available upon request. Rectify to the satisfaction of USCG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 14 August 2024
Resolution: Received email from vessel rep with fire extinguisher servicing report from servicing company.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 11 June 2024
Resolved
A crew accommodation space and a work space must be of sufficient size, adequate construction, and with suitable equipment to provide for the safe operation of the vessel and the protection and accommodation of the crew in a manner practicable for the size, facilities, service, route, and modes of operation of the vessel. The stove top does not have guards/rails to provide adequate protection to crew members and the vessel in all operating conditions. Rectify to the satisfaction of USCG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 29 July 2024
Resolution: Received email from vessel rep with pictures of guards installed on stove top.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 March 2023
Resolved
The owner, manager operator, or master of each towing vessel must maintain the required navigational-safety equipment in a fully-functioning, operational condition. Vessel Anchor light is not operational. Repair or replace to the satisfaction of the attending USCG Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2023
Resolved 31 March 2023
Resolution: Anchor light bulb replaced; all sat.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 28 March 2023
Resolved
Has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: "Attention General Alarm - When Alarm Sounds or Flashes Go to Your Station." GE Alarm is not flashing RED. Repair or replace to the satisfaction of the attending USCG Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2023
Resolved 31 March 2023
Resolution: General Alarm Flashing red light replaced; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 March 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Port generator battery and enclosure are improperly fastened. Secure battery and enclosure to minimize system failure(s) to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2023
Resolved 31 March 2023
Resolution: Battery and enclosure have been secured.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 March 2023
Resolved
Fuel filters must be replaced in accordance with manufacturer's requirements. Port generator fuel filter bottom metal bowl is missing. Repair or replace to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2023
Resolved 31 March 2023
Resolution: Fuel filter bowl has been replaced; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 March 2023
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Clean Lube Oil tank in aft section of engine room has a temporary repair on the bottom-right section of the tank. Tank capacity is approximately 80 gallons and is currently filled with 20 gallons of clean lube oil. Vessel rep is to provide a repair proposal to the local OCMI for review and approval.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2023
Resolved 20 November 2023
Resolution: Permanent repair have been completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 July 2020
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase in period. Owners or managing operators of only one existing towing vessel required to have a COI by this sub chapter must ensure the vessel has on board, a valid COI by July 20, 2020. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no longer be permitted to operate.
Vessel has not yet been able to conduct initial COI. Def code has been changed to a code 60 as 90 days has passed. Vessel is permitted a one time transit from Aransas Marine Ways Shipyard to Live Oak Materials Dock.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 4 March 2022
Resolution: Certificate of inspection was issued to the vessel.
Engineering › Fuel Oil Service System › Tank
Issued 18 February 2008
Resolved
Vsl experienced a loss of propulsion due to water in the fuel system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2008
Resolution: Subject vsl affected permanent repairs to fuel system, rcvd faxed technician''''''''s report from vsl ownership.
Lifesaving
Issued 23 November 1999
Resolved
MISSING 05 PERSONAL FLOTATION DEVICES ONBOARD.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Lifesaving
Issued 23 November 1999
Resolved
VESSEL MISSING 01 BUOY LIFE RING ONBOARD.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Documentation
Issued 23 November 1999
Resolved
VESSEL DOES NOT HAVE THE ORIGINAL CERTIFICATE OF DOCUMENTATION ONBOARD. THE DOCUMENT IS VALID.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Unknown
Issued 23 November 1999
Resolved
OFFICIAL NUMBER NOT PERMANENTLY AFFIXED UPON THE HULL OF THE VESSEL.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Accommodation/Occupational Safety
Issued 23 November 1999
Resolved
VESSEL MISSING EMPLOYEE ASSISTANCE PROGRAM ONBOARD.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Accommodation/Occupational Safety
Issued 23 November 1999
Resolved
VESSEL MISSING DRUG AND ALCOHOL POLICY ONBOARD VESSEL.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Navigation
Issued 23 November 1999
Resolved
VESSEL MISSING LOCAL NOTICE TO MARINERS ONBOARD.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000