Records from 2016 to 2026. Most recent: inspection, 19 May 2026.
Inspection history · 33
19 May 2026
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8378294
10 April 2026
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8345628
24 March 2026
Bulk Liquid Transfer Monitor
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8331486
1 March 2026
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8318057
14 April 2025
Re-Inspection · ACP COI Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8111093
3 December 2024
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8047511
5 November 2024
Re-Inspection · Deficiency Check · ACP COI Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8029638
4 July 2024
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7955649
25 July 2023
Annual Inspection · ACP Annual Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7750666
5 July 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7734337
1 July 2023
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7744364
24 March 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7656006
9 August 2022
In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7543091
19 July 2022
ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 7513454
14 July 2022
ACP Drydock Oversight
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7506267
22 May 2022
Type not recorded
No type recorded · Activities Europe · Activity 7527749
6 April 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7425532
12 April 2021
ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7172751
19 February 2021
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7142724
9 March 2020
ACP Drydock Oversight · ACP COI Oversight · Re-Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6923215
12 December 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6886113
26 August 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6797577
6 August 2019
ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6773728
4 March 2019
Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6636901
25 February 2019
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6635644
3 October 2018
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6553731
19 September 2018
Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6534495
28 March 2018
Drydock Exam · ACP Drydock Oversight
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6380833
11 September 2017
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6266155
21 August 2017
Annual Inspection · ACP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6246999
6 June 2017
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6173075
1 June 2016
Administrative Inspection · ACP Annual Oversight
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5893328
24 May 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5885759
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 November 2024
Resolved
Cargo ships shall carry one or more totally enclosed lifeboats complying with the requirements of section 4.6 of the Code of such aggregate capacity on each side of the ship as will accommodate the total number of persons on board. USNS CHARLES DREW currently does not have 100% capacity on each side of the vessel.
SOLAS III-31/1.1.1
Action required: 705 - Other - as specified
Resolved 2 May 2025
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 13 November 2024
Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters (1 inch) long. It must be located at the top of the flange face, midway between boltholes, and in line with the bolthole pattern. Vapor connections on both port and starboard sides are painted over.
46 CFR 39.2001(j)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 November 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on board. Wastage support brackets IVO lifeboats on poart and starboard sides are wasted.
SOLAS I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 November 2024
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 13 November 2024
Resolved
Each crew berthing area shall be equipped with information regarding-
(A) vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage; and
(d)... In each washing space in a visible location there shall be information regarding procedures and resources to report crimes upon the vessel, including sexual assault and sexual harassment, and vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage. Vessel is to display information and procedures for reporting of SASH incidences in accordance with 46 USC references.
46 USC 11101(a)(5)
46 USC 11101(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 November 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 November 2024
Resolved
Main and emergency switchboards shall be so arranged...nonconducting mats or gratings shall be provided at the front and rear of the switchboard. Matting was not present at switchboards in the steering gear room.
SOLAS II-1/45.2
Action required: 10 - Deficiency Rectified
Resolved 2 May 2025
08 - Alarms › N/A - No Subsystem › General alarm
Issued 13 November 2024
Resolved
The general alarm system shall be capable of sounds the general emergency alarm signal. Attending marine inspector observed a inconsistency within the GA/PA system.
SOLAS III/3.10
LSA Code 7.2.2.1
Action required: 10 - Deficiency Rectified
Resolved 2 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 July 2023
Resolved
Fire detection and fire alarm system shall be kept in good order so as to ensure their required performance if a fire occurs. There is an active fault in the fire detection panel for Zone 7. 74 SOLAS (09) II-2/Reg 14.2.1.1.2
Action required: 10 - Deficiency Rectified
Resolved 3 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 July 2023
Resolved
The condition of the ship and its equipment shall be maintained and no change shall be made in the structural arrangements, machinery, equipment, and any other items covered by the survey, without the sanction of the Administration. The #2 main diesel generator is unable to start. 74 SOLAS (09) I/Reg 11
Action required: 10 - Deficiency Rectified
Resolved 3 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 July 2023
Resolved
Launching and recovery arrangements shall be such that the appliance operator on the ship is able to observe the survival craft at all times during launching and for lifeboats during recovery. During launching of the #3 lifeboat, the davit's lowering handle disconnected from the cable.
74 SOLAS (14) III/Reg 16.3
Action required: 10 - Deficiency Rectified
Resolved 3 August 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 25 July 2023
Resolved
The condition of the ship and its equipment shall be maintained and no change shall be made in the structural arrangements, machinery, equipment, and any other items covered by the survey, without the sanction of the Administration. The emergency generator switchboard hertz meter is inoperable and the 12V ground detection indicating lights are blinking.
74 SOLAS (09) I/Reg 11
Action required: 10 - Deficiency Rectified
Resolved 3 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2023
Resolved
The condition of the ship and its equipment shall be maintained and no change shall be made in the structural arrangements, machinery, equipment, and any other items covered by the survey, without the sanction of the Administration. The engine room's supply and exhaust fans M2, M6, M8, and M10 are inoperable. 74 SOLAS (09) I/Reg 11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 25 July 2023
Resolved
The condition of the ship and its equipment shall be maintained and no change shall be made in the structural arrangements, machinery, equipment, and any other items covered by the survey, without the sanction of the Administration. The port and stbd rescue boats have damages to the self-righting buoyant canopy caused by the launching handle. In addition, the stbd rescue boat's seat back rest for the operator has broken off. 74 SOLAS (09) I/Reg 11
Action required: 10 - Deficiency Rectified
Resolved 3 August 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2023
Resolved
The condition of the ship and its equipment shall be maintained and no change shall be made in the structural arrangements, machinery, equipment, and any other items covered by the survey, without the sanction of the Administration. The eye wash station located in the incinerator room is inoperable. 74 SOLAS (09) I/Reg 11
Action required: 10 - Deficiency Rectified
Resolved 3 August 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for rating for watchkeeping
Issued 20 July 2022
Resolved
Subject to exceptions, 46 U.S.C. 8104 requires that when a master of a seagoing vessel of more than 100 GRT establishes watches for the officers, sailors, and oilers, “the personnel shall be divided, when at sea, into at least three watches and shall be kept on duty successively to perform ordinary work incidental to the operation and management of the vessel.” Only 2 QMED-oilers/Ratings Forming Part of an Engineering Watch )RFPEW - STCW III/4) positions are filled. As noted in the crew list, one position listed as the UJE (W) position is vacant, leaving the two QMED oilers are standing two watches and not in a three watch system.
Cite: 46 CFR 15.705(b)
STCW I/2.1
STCW Code A-VIII/1 and 2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 12 August 2022
Resolution: Placed another qualified CIVMAR on watch to maintain three watch system.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 July 2022
Resolved
Fire detection and fire alarm systems shall be kept in good order so as to ensure their required performance if a fire occurs. Five faults were identified in the fire detection panel.
SOLAS (2009) II-2/Reg 14.2.1.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 5 October 2022
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 20 July 2022
Resolved
Logs of ship stations which are compulsorily equipped for radiotelephony must contain applicable log entries and the time of their occurrence. General entries for testing GMDSS equipment was made in the ship’s GMDSS log book. It did not identify required entries as required in 47 CFR 80.409.
Cite: 47 CFR 80.409(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 12 August 2022
Resolution: Corrected
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 July 2022
Resolved
Nautical charts and nautical publications, such as…tides tables and all other nautical publications necessary for the intended voyage, shall be adequate and up to date. The program supplying tides and currents was no longer functional on board the vessel.
Cite: SOLAS (2009) V/Reg 27
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 5 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 20 July 2022
Resolved
The rations [lifeboat] shall be packed in permanently sealed metal containers or vacuum packed in a flexible packaging material with a negligible vapour transmission rate. Flexible packaging materials shall be further protected by outer packaging if needed to prevent physical damage to the food ration and other items as result of sharp edges. Identified 3 rations with broken vacuum seal and some rations were stored without outer packaging.
Cite: SOLAS (2009) III/Reg 14.4, LSA Code 4.1.5.1.18
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 12 August 2022
Resolution: Corrected
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 July 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Both the port and starboard bridge wing lifebuoys had wasted SOLAS tape, the lifebuoys color is faded, the lifebuoy grablines are deteriorating, and could not get the starboard self-igniting light to illuminate.
Cite: SOLAS (2014) III/Reg 20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 12 August 2022
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2022
Resolved
Test procedure documents must be in a step-by-step or checkoff list format. The crew and technical representatives utilized the "Pre and Post Commissioning Safety Check procedures" to carry out annual testing of equipment. These safety check procedures are not in accordance with the vessel's approved PSTPs.
Cite: 46 CFR 61.40-10
U.S. Supplement to ABS Rules dated
April 1, 2009, see page I-8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 5 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2022
Resolved
The condition of the ship and its equipment shall be maintained and no changes shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the Administration. In conversations with the crew, it was determined that the isolation valves within the #1, #2, and #3 Salt Water Cooling systems leak by substantially. Inspect all isolation valves within the Salt Water Cooling system to verify their operational integrity.
74 SOLAS (09) I/Reg 11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 5 October 2022
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 20 July 2022
Resolved
The condition of the ship and its equipment shall be maintained and no changes shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the Administration. A crack was noted at a corner seam of the storage tank of the MSD. Also noted in the piping and associated valves off of the WD-V-534 Sea Water flushing COV.
Cite: 74 SOLAS (09) I/Reg 11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 5 October 2022
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 20 July 2022
Resolved
The Oil Record Book Part II shall be completed on each occasion, on a tank-to-tank basis if appropriate, whenever cargo/ ballast operations take place in the ship. In Feb 2022, Code “L” transfers were listed in the Oil Record Book Part II. Several entries were made with Code “L” in 2021. The vessel is not equipped with dedicated clean ballast tanks.
Cite: MARPOL Annex I/Reg 36.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 12 August 2022
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 20 July 2022
Resolved
The Company should ensure that each ship is manned with qualified, certificated and medically fit seafarers in accordance with national and international requirements. The vessel was not provided a UJE (W) position, the crewmember assigned as the Rating Forming Part of an Engineering Watch (STCW III/4)/ QMED-Oiler position as required by the COI. A crewmember's medical certificate notated a medical waiver which required compliance, but did not have a copy of the waiver on board the vessel nor did the medical officer.
Cite: SOLAS (2014) IX/Reg 3.1
ISM Code 6.2;
46 CFR 15.705(b);
STCW Annex Reg VIII/1 and VIII/2; A-VIII/1
Medical: 46 CFR 10.303; STCW Annex Reg I/9; A-1/9
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 12 August 2022
Resolution: Placed another qualified CIVMAR on watch to maintain three watch system.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 20 July 2022
Resolved
The safety management system should provide for measures ensuring that the company's organization can respond at any time to hazards, accidents and emergency situations involving its ships. While lowering the #4 lifeboat, a crewmember used his hands to ensure the brake cable would properly pay out when the boat was lowering. Reviewed the SOLAS training manual and could not find any reference to the process. Also, the SOLAS training manuals were not found in all identified locations. The diagrams were difficult to discern the operation of the lifeboat onload release mechanism. The SOLAS training manual on board is not detailed and differs from theSOLAS training manual in the SMS listed as a 2019 "draft" and is more comprehensive.
Cite: SOLAS (2014) IX/Reg 3.1
ISM Code 8.3
SOLAS (2014) III/Reg 35.2, 35.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 5 October 2022
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 20 July 2022
Resolved
The company should ensure that the policy is implemented and maintained at all levels of the organization both ship based as well as shore based.
Numerous food stores on board were found to be passed their labeled expiry date with no documentation provided either extending their lifecycle or deeming them unfit for human consumption per NAVSUP P-486, Vol I, Rev 9 Food Service Management:
1. Po. Lock Hamburger, Raw, Fzn; Expiration: 22Oct2019
2. Alamarai Strawberry Yoghurt; Expiration: 11Jul2022
3. Alamarai Milk; Expiration: 17July2022
4. Brown Bread (2 boxes); Expiration: 12Jul2021
5. Hoagie Rolls; Expiration: 12Jul2021
6. Smucker’s Crustables; Expiration 26May2022
7. Smoked Sliced Cooked Beef Brisket (3 boxes); Expiration: 15Jun2022
8. SL Salami Richmond (4 boxes); Use by: 10Jun2022
9. Cheese, Parmesan, grated; Expiration: 24Jul2022
10. Cereal, Rolled Oats, Inst. Quick Cook; Expiration: 23APR2022
11. Bread Crumbs (2 boxes); Expirations: 2Jun2021; 3Dec2021
12. Quaker cereal, Hominy Grits; 26Jan2022
13. Corn Meal; Expiration: 3Oct2020
14. Grape Juice (canned); Expiration: 6Mar2021
Statements from crew onboard indicated an extended unavailability of an Army Veterinarian or authorized medical representative to survey the fitness of the expired food items onboard. The Medical Services Officer onboard stated a monthly Food Operation Inspection is conducted but noted no expired food items within stores (DD-2973 Inspection Reports from the last 2 months were furnished supporting this statement). Recommend an external SMC Audit of the food handling procedures onboard regarding the processing of expired food, the systemic mechanism of verifying food is fit for human consumption, as well as determining the periodic required availability of shore side support personnel to the fleet (namely an Army Veterinarian or “authorized medical representative” as outlined by NAVSUP P-486, Vol I, Rev 9), to be conducted by the RO (ABS).
Cite: 74 SOLAS (20) XI/3,
ISM (2018) Part A/2.2; MSC – USCG MOA 2021 – Annex II/3 (MSC-ACP)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 12 August 2022
Resolution: Supply departement removed expired food items, reffered to RO (ABS)for external audit of SMS system.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 July 2022
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. Hold back hooks on self-closing doors in fire boundaries were found through the vessel during the course of the inspection.
Action required: 10 - Deficiency Rectified
Resolved 20 July 2022
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 20 July 2022
Resolved
Means of control for flammable liquids in the space shall be provided. Numerous chemical and cleaning products were found stored within the passage way at Frame 83.
Action required: 10 - Deficiency Rectified
Resolved 20 July 2022
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 April 2021
Resolved
EVERY INFLATABLE LIFERAFT SYSTEM SHALL BE SERVICED AT INTERVALS NOT EXCEEDING 12 MONTHS. LAST LIFERAFT SERVICING WAS 20MAR2020. SOLAS 74 A (2020) III/20.8 16a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2021
Resolution: Life raft serviced Survitec Busan, SK.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 April 2021
Resolved
MAINTENANCE SHALL BE CARRIED OUT BASED ON THE GUIDELINES DEVELOPED BY THE ORGANIZATION AND IN A MANNER HAVING DUE REGART TO ENSURING THE RELIABILITY OF FIRE-FIGHTING SYSTEMS AND APPLIANCES. FIRE FIGHTING PRESSURE VESSELS TO: MMR, PURIFIER ROOM, CARGO PUMP ROOM, AFT-MID-FWD PAINT LOCKER, INCINERATOR, EDG, AVIATION LIQUID LOCKER) ARE PAST DUE AS OF NOV2020 FOR HYDROSTATIC TESTING. SOLAS 74 A (2020)
II-2/14.2.2.2 , 16a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 June 2021
Resolution: Unavailibility of USCG approved service supplier, ABS issued OSR 1048 issued due 31 July 2021.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 April 2021
Resolved
ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMEDIATE USE. ALL FIRST AID KITS IN LIFEBOATS AND FRBS ARE EXPIRED. SOLAS 74 A (2020) III/20.2 16a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2021
Resolution: Received demonstrative evidence of new first aid kits placed in all lifeboats/rescue boats.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 12 April 2021
Resolved
CREW MEMBERS WITH ENCLOSED SPACE ENTRY OR RESCUE RESPONSISBILITIES SHALL PARTICIPATE IN AN ENCLOSED SPACE ENTRY AND RESCUE DRILL AT LEAST EVERY TWO MONTHS. LAST ENCLOSED SPACE DRILL WAS CONDUCTED JAN2021. SOLAS 74 A (2020) III/19.3.6
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 April 2021
Resolution: Conducted Sat enclosed space drill.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 February 2021
Resolved
Satellite EPIRB shall be capable of floating free if the ship sinks and of being automatically activated when afloat. It was reported that due to heavy weather the vessel's EPIRB fell and cracked its case. EPIRB cannot currently be stowed in float free arrangement.
SOLAS 74 A. (2020)
IV Reg 7.1.6.4
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2021
Resolved 12 April 2021
Resolution: EPIRB case renewed and restowed in a float free position.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 3 October 2018
Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 15 October 2018
Resolution: Length or beam are now transmitting.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 July 2016
Resolved
Missing non-conductive matting in high voltage space: LC1 (1-18.01). Replace with an approved type of non-conductive matting.
Due 8 August 2016
Resolved 11 August 2016
Resolution: Non-conductive matting in place;attested by ABS Class surveyor during visit on 09JUL16 and pictures forwarded by Master onboard.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 5 July 2016
Resolved
Automatic fire suppression system in cargo hold #2, deck #2, in zone #2, inoperable pending new pneumatically release pilot valve. SOLAS II-2/Reg. 14
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 9 July 2016
Resolution: Satisfactory repairs and operational test of suppression system completed by Class.
Operations/Management › Vessel Safety Management › Designated Person(s)
Issued 5 July 2016
Resolved
Medical Service Officer (MSO) not onboard the vessel at time of inspection to complete verification of procedures for controlled substances.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Completed to the satisfaction of attending MI.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 July 2016
Resolved
Both overhead lights in No. 1, emergency fire pump room inoperable. 46 CFR 111.01(a)(1).
Due 10 July 2016
Resolved 11 July 2016
Resolution: Corrected to the satisfaction of attending MI.