MAURY USCG vessel records
← All vessels

USNS WALLY SCHIRRA

USNS WALLY SCHIRRA is a 2009 public vessel, unclassified. The Coast Guard has recorded 41 inspections since 2016, most recently in February 2026, along with 28 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 2 February 2026.

Built
2009
Last inspected
2 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 February 2026
…with no type recorded12
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9345116
831778
Flag
UNITED STATES
Maury page id
psix-831778

Documentation record

Tonnage as PSIX records it43758 - Simplified, Gross Ton
13127 - Simplified, Net Ton
19546 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

41 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; 2 vessels inspected with it, by name and date; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

USNS LEWIS AND CLARK Freight Ship · MISLE 598787 · 22 May 2022 · activity 7527749USNS CHARLES DREW Freight Ship · MISLE 938614 · 22 May 2022 · activity 7527749USNS LEWIS AND CLARK Freight Ship · MISLE 598787 · 22 March 2022 · activity 7431573

Inspection history · 41

2 February 2026 Deficiency Check · Administrative Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8304712
31 January 2026 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8305277
12 January 2026 Vessel Attendance · ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8296112
19 October 2025 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8256835
9 February 2025 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8356575
23 December 2024 Annual Inspection · Administrative Inspection · ACP COI Oversight · COI Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8050235
1 August 2024 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7972635
6 July 2024 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7950374
5 February 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7861219
5 February 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8053143
26 January 2024 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7855911
25 January 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7857005
20 January 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7852019
20 September 2023 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7794964
24 July 2023 ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7750537
21 April 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7672677
18 April 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7679227
10 April 2023 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7666997
28 December 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7613762
17 December 2022 Administrative Inspection · COI Inspection
Physical examination · Activities Europe · Activity 7607594
22 May 2022 Type not recorded
No type recorded · Activities Europe · Activity 7527749
22 March 2022 Administrative Inspection · Damage Survey
Physical examination · Activities Europe · Activity 7416406
22 March 2022 Type not recorded
No type recorded · Activities Europe · Activity 7431573
3 February 2022 Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 7433554
2 February 2022 Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 7436107
21 December 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7371386
16 September 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7313379
15 September 2021 Type not recorded
No type recorded · Activities Europe · Activity 7313396
5 July 2021 ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 7245724
22 February 2021 ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 7143916
20 January 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7127303
12 November 2020 Administrative Inspection
Administrative · Activities Europe · Activity 7093796
12 September 2019 Annual Inspection · ACP COI Oversight · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6796507
18 June 2019 ACP Drydock Oversight
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6718381
10 March 2019 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6639484
5 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6532646
2 August 2018 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6503138
4 January 2018 ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6324109
10 January 2017 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6066447
14 November 2016 In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6041477
11 July 2016 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5936490

Deficiency record · 28

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 February 2026 Resolved
Whenever an accident occurs to a ship or a defect is discovered, either of which affects the safety of the ship or the efficiency or completeness of its life saving appliances or other equipment, the master or owner of the ship shall report that the earliest opportunity to the Administration, the nominated surveyor or recognized organization responsibility for issuing the relevant certificate, who shall cause investigations to be initiated to determine wither a survey, as required by regulation 7,8,9 or 10 is necessary. The vessel has experienced repeated a UPS alarms associated with the harmonic filters under normal operating circumstances, this most recent situation resulted in a loss of propulsion at the most inopportune time while leaving a channel in the vicinity of a bridge. The failure to previously report the known defect as required and identify the root cause of the alarm created a dangerous situation. Provide full root cause analysis and work with the RO to test and verify the reliability of the propulsion systems associated this marine casualty during a in person attendance.SOLAS 1-11 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2026
Resolved 13 February 2026
Resolution: Received ABS Class Report rectified deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 September 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. USCG FEACT received report of a damaged S-hook that is utilized for securing the No.4 lifeboat in the cradle. In order to rectify this lifesaving deficiency please provide a copy technicians report from the OEM to the RO. RO please create a condition of class for this item for tracking until it has been satisfied and provide the condition finding number to USCG FEACT. SOLAS III/20.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2023
Resolved 4 October 2023
Resolution: ABS has oversight for this repair and has assinged a due date of 26DEC2023. Class report and photo report have been added to FEACT vessel files and MISLE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 August 2023 Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all aspects will remain fit to proceed to sea without danger to the ship or the persons onboard. The LT fresh water and saltwater pumps were unable to automatically transfer operation to the standby pump when the online pump was secured. 74 SOLAS (09) I/Reg 11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 September 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 29 August 2023 Resolved
Oil filtering equipment shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15PPM. Crew was unable to prove proper operation of the OWS during the time of the inspection. MARPOL Annex I
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 September 2023
08 - Alarms › N/A - No Subsystem › General alarm
Issued 29 August 2023 Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all aspects will remain fit to proceed to sea without danger to the ship or the persons onboard. The general alarm beacon, local phone beacon, and sound powered phone beacon in the auxiliary cargo pump room are all inoperable when activated. 74 SOLAS (09) I/Reg 11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 September 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 August 2023 Resolved
All electrical panels shall be constructed and so installed as not to cause injury when handled or touched in the normal manner. Electrical panel P420B and P420C cover latch are broken and unable to be lock close. 74 SOLAS (09) II-1 Reg 45.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2023 Resolved
This regulation is to control the spread of smoke in order to minimize the hazards from smoke. For this purpose, means of controlling smoke in machinery spaces shall be provided. Found missing fire stop in cable pass through bulkheads in Electrical Sub Station LC5 01-39.5-1, Station No.2 Motor Control Room, and Electrical Equipment Room 1-24-2. 74 SOLAS (09) II-2 Reg 8.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 29 August 2023 Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all aspects will remain fit to proceed to sea without danger to the ship or the persons onboard. The natural ventilation's cover is missing its gasket 01-49-2. 74 SOLAS (09) I/Reg 11
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 August 2023 Resolved
The condition of the ship and its equipment shall be maintained and no change shall be made in the structural arrangements, machinery, equipment, and any other items covered by the survey, without the sanction of the Administration. The eye wash station located in the carpentry shop is inoperable. 74 SOLAS (09) I/Reg 11
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 August 2023 Resolved
Lifebuoys and life jackets must be marked in block capital letters with the name of the vessel. Found 06 life jackets not marked and lifebuoy FR# 26 markings are faded. 46 CFR 199.70
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 August 2023 Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all aspects will remain fit to proceed to sea without danger to the ship or the persons onboard. The #4 life boat's door hinge is missing a cotter pin. 74 SOLAS (09) I/Reg 11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 September 2023
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 29 August 2023 Resolved
A firefighter’s outfit shall consist of axe with a handle provided with high-voltage insulation. All firefighter’s outfits are not outfitted with and axe as required. 74 SOLAS (20) II-2 Reg 10.1.1 FSS Code 3.2.1.1.5
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 September 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 14 April 2022 Resolved
Every company should develop, implement and maintain a safety management system which includes the following functional requirements ... 1. As per MSC policy 7.1-007-ALL the SW cooling system piping leak/condition was considered a “class 4 casrep,” which means the ship was required to remain in port/return to port immediately for repairs. The vessel remained on UNREPing schedule for mission completion over numerous days even with conflicting recommendations to management from the Chief Engineer and Chief Mate. 2. The vessel has missed several maintenance periods over the last four years, which may be leading to the substandard condition of the vessel, including extensive soft patches on vital piping systems, as identified upon walk-through inspection of engineering spaces. 3. An oiler on board the vessel made two suicide attempts while the vessel was underway. It appears management and/or the medical officer (MSO) failed to follow company policy (SMS and med manual) with handling this member. 4. MSC has a “Gangway Up” policy that has been in place since COVID started that is impacting the crew’s ability to leave the ship. There appears to be manning discrepancy associated with what MSC requires for the vessel operations (potentially 70% manning below MSC requirements). Request review of operational manning requirements compared to company policy. 5. The food stores on board the vessel were found to have numerous items expired (months to years). Crew reported there is an "Army Vet" that evaluates the expired food and then extends the expiration dates. Documentation on policy and procedures could not be brought forward. Request review applicable SMS procedures related to acceptance, handling, and disposal of food. Due to these issues and concerns for the crew's safety, External SMC Audit to be conducted by the RO (ABS) prior to ship's release from Flag State detention. The scope of the audit shall include, but not limited to, the above referenced SMS policies and procedures and focus on crew’s safety, vessel management, and potential fleet-wide impacts. Cites: 4 SOLAS (20) IX/5 ISM (2018) Part A/1.4 MSC-USCG MOA 2021 - Annex II/3 (MSC-ACP)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 14 April 2022
Resolved 4 May 2022
Resolution: Recieved ISM Audit Report from ABS documenting ISM audit.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 22 December 2021 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. After USCG deficiencies were issued to the vessel, the company did not maintain deficiency due dates. In addition, the due dates for ABS issued survey finding(s) were not maintained after multiple notices to the vessel/company. This resulted in ABS suspending vessel from class. SOLAS (2009 Cons) XI-1/5 ISM Code Part A 10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 January 2022
Resolved 28 January 2026
Resolution: Vessel has had the issue(s) identified in the deficiency corrected for some time and has had Class (ABS) re-issue certificates including for ISM.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 November 2021 Resolved
Two aft doors in the Incinerator room self-closing swing arms were wasted unable to self-close. “Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing.” Replace or repair self-closing swing arms so doors self-close. SOLAS (09) II-1/9.4.2.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 December 2021
Resolved 20 November 2021
Resolution: Accepted by ABS, finding number 1108.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 November 2021 Resolved
Forward door in the incinerator room has door handle that is inoperable from inside the incinerator space. “Escape routes shall be maintained in a safe condition”. Replace or make door handle operable in the incinerator room. SOLAS (09) II-1/13.1.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2021
Resolved 20 November 2021
Resolution: Accepted by ABS, finding # 1109
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 November 2021 Resolved
Smoke Detector in the passageway to aft steering was covered in tape and unable to detect smoke. “Fire patrols shall provide an effective means of detecting and locating fires and alerting the navigation bridge and fire teams.” Make smoke detector operable. SOLAS 09 II-2/17.1.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 11 November 2021
Resolved 11 November 2021
Resolution: Tape was removed and satisfactory tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 November 2021 Resolved
Insulation on #3 Main Diesel Generator was missing lagging on the exhaust. “Surfaces with temperatures above 220°C which may be impinged as a result of a fuel system failure shall be properly insulated.” Properly insulate exhaust on #3 Main Diesel Generator. SOLAS 09 II-2/4.2.2.6
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 December 2021
Resolved 1 December 2021
Resolution: Accepted by ABS, finding # 1111.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 November 2021 Resolved
Soft patch was found on waste drain pipe in the engineers special tool room. “The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations.” Make permanent repairs on piping. SOLAS 09 I/11
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 11 November 2021
Resolved 11 November 2021
Resolution: Permanent repairs made.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 November 2021 Resolved
Cable Run in Aft Steering Compartment had a cable from the overhead to the Main Steering gear that was secured by plastic zip ties. “Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured.” Cable retention devices (metallic band strapping) should be installed not less than every 610 mm (24 inches) on vertical runs in accordance with IEEE 45 – Recommended Practice for Electrical Installations on Shipboard. Secure cable run with metal band stripping every 24 inches or provide evidence of approved material for securing vertical cable run. SOLAS 09 II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 December 2021
Resolved 20 November 2021
Resolution: Accepted by ABS, finding # 1114.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 November 2021 Resolved
Fire doors in the stair tower did not automatically close. “Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-"0" class divisions and be protected by self-closing doors at all levels.” Adjust fire doors so they are self-closing. SOLAS (09) II-1/9.2.3.4.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 December 2021
Resolved 20 November 2021
Resolution: Accepted by ABS, finding # 1115.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 November 2021 Resolved
The emergency light installation was detached from the bulkhead above the port lifeboat operating procedure placard. "Emergency lighting for mustering and abandonment shall be tested at each abandon ship drill." Make emergency light operable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 December 2021
Resolved 1 December 2021
Resolution: Accepted by ABS, finding # 1117.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 September 2019 Resolved
ABS Steel Rules 4/4/1.17 - The No.2 ships service air pressure vessel is rated at 450 psi MAWP. The relief valve is to be set at not more than the MAWP. The installed relief valve is set at 479 PSI. replace the relief valve with one rated for its intended service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2019
Resolved 28 February 2021
Resolution: Vessel chief engineer produced pictures showing all pressure vessel PRV's are IAW ABS rules
01 - Certificates & Documentation › 011 - Ships Certificates › Engine International Air Pollution Prevention Certificate (EIAPP)
Issued 12 September 2019 Resolved
Missing EPA approved NOx technical files . Provide NOx technical files for each generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 28 February 2021
Resolution: Chief engineer produced EIAPP, NOX technical files, Record Book and Engine Parameters.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 12 September 2019 Resolved
The supplement to the IOPP certificate dated 30SEP2014 list 5 sludge collection tanks. The volume of the tanks do not match ship records. The waste oil tank is connected directly to the oily water bilge tank. Prove compliance with MARPOL I.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2019
Resolved 17 December 2022
Resolution: New IOPP form B was being issued at the time of the 17DEC22 inspection. Tank volumes had been corrected and updated.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 5 September 2018 Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 October 2018
Resolution: Verified in VIVS
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 2 August 2018 Resolved
During testing of #1 L/B launching, the gripes failed to release properly, after proper release, the hold back failed to swivel and caused damage to the davit support.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 August 2018
Resolved 17 August 2018
Resolution: Cleared by Class after repair and testing.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 August 2018 Resolved
MCT penetrations found with loose fitting comms cables as well as mixed methods of sealing material.
Action required: 705 - Other - as specified
Resolved 17 August 2018
Resolution: Rectified to satisfaction of Class. Both materials used in MCT are compatible.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.