MAURY USCG vessel records
← All vessels

CELEBRITY ECLIPSE

CELEBRITY ECLIPSE is a 2010 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2016, most recently in November 2025, along with 20 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 12 November 2025.

Built
2010
Last inspected
12 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9404314
939439
Flag
MALTA
Maury page id
psix-939439

Inspections, by type

…with no type recorded1
Years with a record 9 calendar years (2016–2025)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it61530 - Displacement, Ton
9600 - Dead Weight, Ton
121878 - Convention (Subpart B), Gross Ton
82363 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 28

12 November 2025 COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8267833
7 November 2024 PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8029793
30 August 2024 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7992446
16 May 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7913309
11 May 2024 COC-CVE Annual · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7907608
5 November 2023 COC-CVE Quarterly · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7819811
10 May 2023 PSC A · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7684956
15 September 2022 Ballast Water Examination · ISPS Exam · COC-CVE Quarterly · PSC B
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7557522
13 April 2022 PSC B · COC-CVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7429087
29 September 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7323362
7 December 2020 Administrative Inspection
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 7108941
2 November 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7088301
13 May 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6953192
8 May 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6953321
2 April 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6934636
31 March 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6934609
3 October 2019 ISPS III Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6822856
11 April 2019 In-Service Inspection · ISPS III Exam · NPV Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6660501
10 April 2019 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6660155
8 April 2019 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6647374
8 April 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6660415
29 November 2017 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6314795
26 November 2017 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6312801
31 October 2017 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6298135
20 October 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6291536
4 November 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6035339
2 November 2016 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6033679
7 March 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5828660

Deficiency record · 20

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 November 2025 Resolved
The ollowing functional requirements hsall be met escape routes shall be mainained in a safe condition, clear of obstacles. PSCOs observed wheelchair being stowed outside of passenger cabin on deck 11, cabin 1524. The wheelchair had an instruction card to be moved inside the cabin once the passenger arrived. 74 SOLAS (20) II-2/13/1/2 Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 November 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 November 2025 Resolved
Hold back hooks not subject to central control station release are prohibited. PSCOs observed FD-02-6-030 being held open by a string and metal nozzle. 74 SOLAS (20) II-2/9.4.1.1.5.4 Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 November 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 November 2024 Resolved
The widths, number and continuity of escapes shall be in accordance with the requirements in Fire Safety Systems Code. Shall not be less than 900 mm in clear width. PSCOs observed an escape path that was fully blocked and impassable caused by boxes and other stored equipment on deck 5, port side, behind FD-05-6-001. 74 SOLAS (20) CH. II-2 Reg. 13.3.2.4.5 FSS Code 13.2.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2024
Resolved 7 November 2024
Resolution: Cleared on the spot.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 November 2024 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCOs observed a CO2 control station in the garbage room that was obstructed by four waste containers. 74 SOLAS (20) Ch. II-2 Reg. 14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 7 November 2024
Resolution: Cleared on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 November 2023 Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks of passenger ships, the minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 9.1 and 9.2. PSCO observed combustible materials being stored in AC room 4-00. Crew removed combustibles from space prior to completion of exam. 74 SOLAS 20 II-2/9.2.2.3.1
Action required: 10 - Deficiency Rectified
Resolved 5 November 2023
Resolution: Crew removed combustibles from space prior to completion of exam.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 15 September 2022 Resolved
Where it is necessary that a ventilation duct passes…The operating position shall be readily accessible and be marked in a red light-reflecting colour. Marine Inspector observed the fire damper AM-7-02.2-02.1/FD1 indicating light extinguished. SOLAS 20 II-2/9.4.1.1.9
Action required: 10 - Deficiency Rectified
Resolved 15 September 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 September 2022 Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. Marine Inspector observed miscellaneous items stored in a stairwell obstructing means of escape. SOLAS 20 II-2/13.1.2
Action required: 10 - Deficiency Rectified
Resolved 15 September 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2022 Resolved
Crewmembers shall receive instruction on fire safety on board the ship. Marine Inspector discovered crewmember smoking in crew cabin 3528. SOLAS 14 II-2 15.2.1.1
Action required: 10 - Deficiency Rectified
Resolved 15 September 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 September 2022 Resolved
Hold-back hooks not subject to central control station release are prohibited. Marine Inspector observed a rope holdback on fire door 00-3-009 giving access to a dry store room. SOLAS 14 II-2/9.4.1.1.5.4
Action required: 10 - Deficiency Rectified
Resolved 15 September 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 September 2022 Resolved
In addition to the emergency lighting required by regulations II-1/42 and III/11.5, the means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. Marine Inspector observed provisions blocking low location lighting on escape route in vicinity of Sunset Diner. SOLAS 14 II-2/13.3.2.5.1
Action required: 10 - Deficiency Rectified
Resolved 15 September 2022
Lifesaving › Lifeboat › Propulsion Engine
Issued 26 November 2017 Resolved
0610 - #20 lifeboat engine is not working due to mechanical failure. 74 SOLAS (2014) III/34, LSA Code 4.4.6.3, 50 a c
Action required: 705 - Other - as specified
Due 26 December 2017
Resolved 21 December 2017
Resolution: The fuel oil pump for lifeboat #20 engine was replaced. The engine was tested and the boat was maneuvered in the water in the presence of the attending DNV GL surveyor.
Fire Fighting › Means of Escape › Corridors
Issued 4 November 2017 Resolved
Safe escape routes shall be provided. Restaurant manager office in main dining room deck 4 only exits through the main dining room. No communication is provided between space. (room in room). 74SOLAS(14)II-2/13.1.1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 December 2017
Resolved 21 December 2017
Resolution: An installation of the room-in-room alarm was surveyed and the room-in-room alarm was tested to the satisfaction of the attending surveyor. The installation has been carried out by the manufacturer Autronica.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 4 November 2017 Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the organization and in a manner having due regard ensuring the reliability of fire-fighting systems and appliances. Numerous fire extinguishers on deck 5 found missing monthly inspections for October. 74 SOLAS (14) II-2/14.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2017
Resolved 24 November 2017
Resolution: Fire extinguishers were verified checked from original checklist and personnel were trained on proper documentation.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 4 November 2017 Resolved
Doors shall be self closing. Doors 15-3-005, 065-5-008 and 02-6-026 failed to close within required timelines. 74 SOLAS (14) II-2/9.4.1.1.5.1
Action required: 705 - Other - as specified
Due 4 November 2017
Resolved 4 November 2017
Resolution: Doors re-sequenced and sequencers repaired to close within timelines.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 November 2017 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. Embarkation lights aft of Lifeboat 11 and lifeboat 19 found extinguished. 74 SOLAS (14) III/11.4
Action required: 705 - Other - as specified
Due 4 November 2017
Resolved 4 November 2017
Resolution: Lights repaired and working.
Fire Fighting › Means of Escape › Corridors
Issued 4 November 2017 Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. Corridor in medical Deck 2 FWD found partially obstructed by stacked boxes of medical equipment. 74 SOLAS (14) II-2/13.1.2
Action required: 705 - Other - as specified
Due 4 November 2017
Resolved 4 November 2017
Resolution: Boxes removed.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 4 November 2017 Resolved
Each liferaft or group of liferafts shall be stowed with a float free arrangement. Float free liferafts amidships port and starboard were found with improperly installed hydrostatic release devices, preventing quick release of liferafts. 74 SOLAS (14) III/13.4.2
Action required: 705 - Other - as specified
Due 4 November 2017
Resolved 4 November 2017
Resolution: Hydrostatic release units were re-installed in correct arrangment.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 4 November 2017 Resolved
On a ship engaged on a voyage where passengers are scheduled to be on board for more than 24 hrs, muster of the passengers shall take place prior to or immediately upon departure. PSCO was unable to observe passenger muster since no passengers embarked in Boston. 74 SOLAS (14) III/19.2.2
Action required: 705 - Other - as specified
Due 18 November 2017
Resolved 29 November 2017
Resolution: Not required.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 5 November 2016 Resolved
Multiple Fire Safety Doors found with blocks which prevented closure of the doors in the garbage rooms. Also pallets found blocking the same dooors.
Due 5 November 2016
Resolved 5 November 2016
Resolution: Hold bach blocks and pallets have been removed.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 5 November 2016 Resolved
Missing structural fire protection A-60 boundary was found on vent duct in the theater stage left.
Due 5 November 2016
Resolved 5 November 2016
Resolution: SFP has been added and deficiency have been resolved. SAT.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.