MAURY USCG vessel records
← All vessels

CAPT MEL

Built
1967
Last inspected
17 June 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 17 June 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (1987–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF5638
Flag
UNITED STATES
Maury page id
psix-94026

Documentation record

Registered dimensions (L × B × D)68.8 ft × 22.2 ft × 6.2 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAIN IRON WORKS INC · HOUMA, LA, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDELTAVILLE, VA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 5 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DEFENDER Towing Vessel · MISLE 210428 · 29 November 2020 · activity 7103577THUNDER Towing Vessel · MISLE 1158103 · 29 November 2020 · activity 7103577LADY THEO Towing Vessel · MISLE 130324 · 25 February 2018 · activity 6362769CAVALIER STATE Towing Vessel · MISLE 160690 · 25 February 2018 · activity 6362769DERRICK 64 Industrial Vessel · MISLE 813366 · 25 February 2018 · activity 6362769

Inspection history · 16

17 June 2025 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8161570
26 July 2024 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7967407
20 March 2024 COI Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7862683
16 January 2024 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7849639
21 November 2023 TPO Audit
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7828069
31 July 2023 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7757062
29 November 2020 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7103577
2 April 2019 Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6659442
14 November 2018 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6580760
25 February 2018 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6362769
5 June 2012 Industry Initiated Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4311431
26 October 2011 Administration
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4226176
4 February 2009 MTSA Verification · Hawser Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3412149
23 December 2006 MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2845302
29 March 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2612116
13 July 1987 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1026671

Deficiency record · 17

10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 June 2025 Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Vessels Rose Point Chart system has not been updated since February 2023. 46 CFR 140.705
Action required: 17 - Rectify deficiencies prior to departure
Due 17 June 2025
Resolved 17 June 2025
Resolution: Rose Point chart system was successfully updated before inspection was completed.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 17 June 2025 Resolved
In the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm—When Alarm Sounds or Flashes Go to Your Station”. Signage was not posted at general alarm in engine room. 46 CFR143.235(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 2 July 2025
Resolution: vessel ordered new signage to meet requirements. Verified photo of invoice.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Machinery alarm panel in fiddley and galley was missing multiple bulbs leaving empty socket. 46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 2 July 2025
Resolution: Vessel engineer replaced open receptacles with blanks eliminating hazard. verified with photo documentation.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 June 2025 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Vessel remote fuel shutoff was not operational. 46 CFR 143.260(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 17 June 2025
Resolved 17 June 2025
Resolution: Pull cable adjusted and retested satisfactorily.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 March 2024 Resolved
A towing vessel subject to this section must maintain a Towing Vessel Record. Vessel has not maintained their TVR. 46 CFR 140.910
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 17 May 2024
Resolution: Vessel Rep sent record of TVR.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 20 March 2024 Resolved
The master or person in charge of a ship, to which this section applies shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. Vessel did not have a garbage placard displayed onboard.33 CFR 151.59
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 17 May 2024
Resolution: Photo of GMP posted sent by vessel rep.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 March 2024 Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Vessel has not conducted required tests on air receiver pressure relief valves.46 CFR 143.245(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 19 April 2024
Resolution: Vessel showed record of test, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 March 2024 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Generator coils on both generators were excessively dirty.46 CFR 143.400(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 19 April 2024
Resolution: Coils were cleaned to satisfaction on CGMI, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 March 2024 Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) STBD side air receiver did not have a pressure gauge. 46 CFR 143.300(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 19 April 2024
Resolution: Installed gauge.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 March 2024 Resolved
Alarms must be visible and audible at each operating station. Alarm indicating light at main operating station for STBD main diesel engine alarms did not operate. 46 CFR 143.230(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 19 April 2024
Resolution: Tested alarms, all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 March 2024 Resolved
Alarms must continue until they are acknowledged. Alarms for bilge flooding, and main diesel engines cleared automatically once alarm condition no longer existed.46 CFR 143.230(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 19 April 2024
Resolution: Alarms tested and functioned IAW CFR 143.230(b)(3)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 March 2024 Resolved
Alarms must be visible and audible at each operating station. Main diesel engine alarms did not operate at upper operating station. 46 CFR 143.230(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 19 April 2024
Resolution: Tested alarms, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 March 2024 Resolved
Each towing vessel must be equipped with a means to detect smoke in lounges that alerts individuals in those spaces. Vessel did not have smoke detector in galley lounge area. 46 CFR 142.330(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 6 June 2024
Resolution: Recieved photos as objective evidence of UL approved smoke alarms installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 March 2024 Resolved
Means must be provided for closing, in case of fire,openings into machinery spaces. Vessel did not have closures for engine room mushroom ventilation and vent fan leading to head. 46 CFR 144.605
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 17 May 2024
Resolution: Plate installed on fwd bulkhead over vent leading to head. Canvas covers were made for engine room mushroom ventilation.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 20 March 2024 Resolved
There must be an installed or portable bilge pump for emergency dewatering. Installed bilge suction serving lazarette was found inoperable due to seized suction valve. 46 CFR 143.275
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 19 April 2024
Resolution: Tested bilge suction from lazaratte, all sat.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 20 March 2024 Resolved
Vessel must have in the engine room, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm—When Alarm Sounds or Flashes Go to Your Station” Vessel’s red flashing light in engine room was inoperable and missing sign. 46 CFR 143.235(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 19 April 2024
Resolution: witnessed light and signage installed and tested, all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 20 March 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard. Fire pump held up with wood blocks and not properly secured.46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 19 April 2024
Resolution: Fire pump permanently installed, all sat.

Recorded names · 1

BOBBIE ANN (2020). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.