MAURY USCG vessel records Sign in
← All vessels

MM 32

MM 32 is a 2008 tank barge. The Coast Guard has recorded 28 inspections since 2008, most recently in July 2026, along with 10 deficiencies and 1 casualty investigation in 2010.

Records from 2008 to 2026. Most recent: inspection, 20 July 2026.

Built
2008
Last inspected
20 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

943749
Flag
UNITED STATES
—
Maury page id
psix-943749

Inspections, by type

…with no type recorded5
Years with a record 18 calendar years (2008–2026)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2008
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 July 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Net Ton
1754 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS KATHY Towing Vessel · MISLE 127072 · 17 August 2010 · activity 3826498MM 57B Tank Barge · MISLE 560944 · 17 August 2010 · activity 3826498MM 30 Tank Barge · MISLE 879668 · 17 August 2010 · activity 3826498

Inspection history · 28

20 July 2026 Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8434702
21 July 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8188191
26 June 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7941995
10 May 2023 COI Inspection · Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7685306
2 February 2022 Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7389471
16 July 2021 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7256227
6 July 2020 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7002730
9 December 2019 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6870330
16 July 2019 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6751987
2 April 2018 COI Inspection · Cargo Tank Internal · Administrative Inspection · Examination of Repairs · MTSA Verification · Special · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6383576
28 June 2017 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6190793
18 October 2016 Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6024812
28 January 2016 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5807400
23 June 2015 Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5161389
8 July 2014 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4915535
14 January 2014 Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4782816
4 December 2012 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4495904
25 June 2012 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4357357
16 August 2011 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4118404
17 August 2010 Type not recorded
No type recorded · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3826498
24 June 2010 Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3787265
24 March 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3702200
22 March 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3702150
14 March 2010 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3695500
9 September 2009 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3590824
9 September 2009 Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3590839
29 September 2008 Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3335072
25 June 2008 Cargo Tank Internal · Administrative Inspection · Deadweight Survey · Initial Construction-Excluding Oversight · Initial Certification · Internal Structural Exam · MTSA Verification · Hull Examination
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3247466

Deficiency record · 10

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 February 2022 Resolved
A fixed pressure-sensing device must be installed as close as practicable to the vessel vapor connection on a tank barge with a vapor collection system. The pressure-sensing device must measure the pressure vacuum in the main vapor collection line and have a pressure indicator located where the cargo transfer is controlled. The gauge on the vapor line was inoperable. Gauge was replaced on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 February 2022
Resolved 3 February 2022
Resolution: Operator replaced gauge during inspection.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 July 2020 Resolved
Thermal Fluid Heater (TFH) internal visual inspection revealed the thermal insulation was peeling away on the rear portion of the chamber. Repair/replace insulation prior to use of the TFH.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2020
Resolution: Missing insulation replaced.
Lifesaving › Lifebuoys › Immediately Available
Issued 9 September 2009 Resolved
life Ring needs to be readably accessible
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 September 2009
Resolved 16 September 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 9 September 2009 Resolved
Properly Mount Fire extinguisher in bracket.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 September 2009
Resolved 16 September 2009
Electrical › Mast › Lightning Ground
Issued 9 September 2009 Resolved
Wire connections on running lights out of sheathing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2009
Resolved 16 September 2009
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 9 September 2009 Resolved
2 port gauging stick binding
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2009
Resolved 16 September 2009
Engineering › Fuel Oil Service System › Filter
Issued 9 September 2009 Resolved
Missing Flash Bowl for Fuel Filter on Generator set
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 September 2009
Resolved 16 September 2009
Deck/Cargo › Cargo Stowage › General
Issued 9 September 2009 Resolved
Label Flammable locker orremove flammables
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2009
Resolved 16 September 2009
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 25 June 2008 Resolved
Provide a copy of the vessel response plan and approval letter onboard the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 June 2008 Resolved
Replace cargo pump engine wiring harness with approved harness NLT 01 Aug 08 or in compliance with submitted plan as per D8 policy letter 02-2007.
Action required: 705 - Other - as specified
Due 18 June 2010
Resolved 18 April 2013
Resolution: Engine relocated outside class I Div I hazardous zone.

Casualty record · 1

17 August 2010Routine · role: Involved in a Marine Casualty · activity 3826498
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.