Records from 2008 to 2025. Most recent: inspection, 20 October 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2008
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 July 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Net Ton
1754 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 28
20 October 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8255513
4 February 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8074393
23 January 2025
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8068815
23 October 2023
Internal Structural Exam · Examination of Repairs · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7810437
9 August 2022
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7529367
15 September 2021
Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7313927
28 August 2020
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7044642
27 August 2019
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6797430
2 July 2018
Damage Survey · MTSA Verification · Administrative Inspection · Examination of Repairs · Cargo Tank Internal · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6464046
27 September 2017
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6277295
22 August 2016
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5976272
14 August 2015
Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5219112
3 August 2015
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5205053
14 October 2014
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5004681
14 January 2014
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4782751
6 August 2013
Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4676922
9 July 2013
In-Service Inspection · MTSA Verification · Examination of Repairs · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4650510
21 June 2013
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4632263
20 June 2013
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4627237
15 August 2012
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4411685
14 August 2012
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4411748
2 July 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4365011
5 August 2011
Annual Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4104105
25 August 2010
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3825927
17 August 2010
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3827568
5 June 2009
Annual Inspection · Deficiency Check · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3495920
30 September 2008
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3335733
9 July 2008
Initial Construction-Excluding Oversight · MTSA Verification · Administrative Inspection · Initial Certification · Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3260748
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 23 January 2025
Resolved
(f) The frequency of the tests and inspections required by this section must be:
(3) For vessels, annually or as part of the biennial and mid-period inspections.
Port aft cargo pump relief valve was missing tag and paperwork showing proof of testing and calibration. Port aft IMO-style cargo pump shall not be used for cargo operations until proof of calibration and testing is provided.
Action required: 705 - Other - as specified
Resolved 4 February 2025
Resolution: Valve replaced with valve tested on 11/16/2024; testing and calibration documentation provided and placed on board vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 January 2025
Resolved
The applicable standards established by the ABS Marine Vessel Rules (incorporated by reference, see § 58.03-1), may be used as the standard for the design, construction, and testing of main and auxiliary machinery except as modified in this subchapter.
Starboard cargo pump prime mover RPM, jacket water temperature, and oil pressure gauges were inoperable. Make repairs to the same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2025
Resolved 4 February 2025
Resolution: Vessel rep proved proper operation of pump engine gauges.
Deck/Cargo › Cargo Heating › General
Issued 22 August 2016
Resolved
Low Fuel Oil PSI Alarm of Thermal Fluid Heater was found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2016
Resolution: Replaced sensor switch and conducted operational test of shutdown to satisfaction of attending MI.
Stability › Watertight Integrity › General
Issued 4 August 2015
Resolved
During this inspection, an inset of 7-8 inches over approximately 3 feet at the deck gunnel with an approximate 1/2 inch fracture in the deck in the way of the #3 port wing tank was discovered. An epoxy temp repair was made to the 1/2 inch fracture on deck and a CG 835 was issued for 30 days to make permanent repairs sat to CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 September 2015
Resolved 17 August 2015
Resolution: Attended vessel to verify permanent repairs of damage and conduct air testing of welds. All sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2012
Resolved
Replace cargo pump engine wiring harness NLT 01 NOV 2015 or IAW D8 letter dated 05 NOV 2010.
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 23 August 2013
Resolution: Relocated cargo pump engine outside the class1 div 1 hazardous zone.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 5 June 2009
Resolved
Replace matting w/ approved DECK COVERING as per 46CFR111.30-11.
Condition: Improper Installation
Due 5 June 2009
Resolved 5 June 2009
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 July 2008
Resolved
Replace cargo pump engine wiring harness NLT 01 Aug 08 or in compliance with submitted D8 plan as per D8 policy letter 02-2007.
Action required: 705 - Other - as specified
Due 18 June 2010
Resolved 14 August 2012
Resolution: New CG 835 issued extending compliance date to 01 NOV 2015