MAURY USCG vessel records
← All vessels

DAVID FANNING

Built
2008
Last inspected
22 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 22 July 2026
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 17 calendar years (2008–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE6925
949513
Flag
UNITED STATES
Maury page id
psix-949513

Documentation record

Registered dimensions (L × B × D)238.7 ft × 64.5 ft × 23.5 ft
Registered tonnagegross 2,724 / net 1,403
ITC dimensions (L × B × D)238.7 ft × 64.5 ft × 23.5 ft
ITC tonnagegross 2,724 / net 1,403
BuilderUS BARGE LLC · PORTLAND, OR, UNITED STATES · built 2008
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEATTLE, WA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 19 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2724 - Convention (Subpart B), Gross Ton
1403 - Convention (Subpart B), Net Ton
5395 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 35 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TIM QUIGG Towing Vessel · MISLE 664066 · 27 October 2010 · activity 3879899ERNEST CAMPBELL Towing Vessel · MISLE 101698 · 20 January 2010 · activity 3669439

Inspection history · 35

22 July 2026 MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8371216
3 December 2025 Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8149783
12 August 2025 MARPOL Annex I Examination · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8148126
6 June 2024 MARPOL Annex I Examination · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7905652
6 December 2023 MARPOL Annex I Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7834750
2 November 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7802970
18 August 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7715816
20 July 2022 Periodic Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7466300
9 December 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7365410
1 September 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7302217
18 December 2020 Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7115326
27 August 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7044006
20 December 2018 Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6718619
6 December 2018 COI Inspection · Internal Structural Exam · Cargo Tank Internal · Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6577497
1 February 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6290971
16 November 2016 Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6021717
29 August 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5994511
12 February 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5777133
16 April 2015 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5104417
1 December 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5032491
20 May 2014 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4863195
9 December 2013 Internal Structural Exam · Drydock Exam · COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4767215
9 February 2012 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4224515
22 December 2011 Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4212192
23 August 2011 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4123963
27 October 2010 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3879899
10 September 2010 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3847150
8 March 2010 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3689452
22 January 2010 Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3668466
20 January 2010 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3669439
10 August 2009 In-Service Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3561469
22 March 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3438037
7 March 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3429775
21 February 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3422644
10 December 2008 Construction Oversight · COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3374080

Deficiency record · 14

09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 18 August 2023 Resolved
All exposed and dangerous places such as gears and machinery shall be properly protected with covers, guards or rails in order that the danger of accidents may be minimized. MI observed exhaust manifold and piping on generator missing lagging. Replace lagging on dry exhaust system for generator. 46 CFR 32.02-15(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2023
Resolved 13 September 2023
Resolution: new lagging installed
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 1 September 2021 Resolved
Oil tankers and offshore oil barges with an overall length of less than 400 feet must carry appropriate equipment and supplies for the containment and removal of on deck oil spills of at least 7 barrels. Barge does not have a full compliment of oil spill equipment. Vessel rep was able to find all sopep equipment and bring it onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 September 2021
Resolved 1 September 2021
Resolution: Vessel rep found all SOPEP equipment and brought it onboard.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 11 December 2018 Resolved
Suction valve on #1 port cargo tank remote indicator was showing partial open when closed. Repair gate valve indicator to reflect actual position (open/close).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2018
Resolved 12 December 2018
Resolution: Attending MI verified proper remote indication of #1 port cargo tank.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 11 December 2018 Resolved
Remote indicator for suction valve in #4 stbd cargo tank was disconnected. Reconnect and test indicator.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 December 2018
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 December 2018 Resolved
Show that the BII (40BC) Portable Extinguishers (2) on deck had received an annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2018
Resolution: Fire extinguishers inspected by a Certified Technician.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 6 December 2018 Resolved
Identified a damaged stiffener (bent) between the #2 and #3 vertical frames in vicinity of the Port Bow rake. This damage requires repair to original construction. Repair to be completed prior to but no later than next scheduled dry dock.
Action required: 705 - Other - as specified
Resolved 11 December 2018
Resolution: Damaged stiffener repaired to the satisfaction of USCG.
Lifesaving › Lifebuoys › Serviceable
Issued 1 February 2018 Resolved
Wasted retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 16 February 2018
Resolution: Retro was replaced
Electrical › Lighting (service) › Lighting Fixture
Issued 12 February 2016 Resolved
Make port aft flood light above deck house explosion-proof. Circuit must be isolated and tagged out until corrected to satisfaction of CG Marine Inspector. 46CFR111.105-3
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 March 2016
Resolved 7 March 2016
Resolution: Received satisfactory evidence that light fixture was replaced in kind.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 February 2016 Resolved
Replace in kind waterlight line attached to both life ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2016
Resolved 7 March 2016
Resolution: Vessel rep replaced all grab lines for lifebuoys with approved type.
Engineering › Reduction Gearing/Clutches › Hose
Issued 1 December 2014 Resolved
Replace nonmetallic flexible hose on STBD hydraulic pump supply.
Action required: 705 - Other - as specified
Due 17 December 2014
Resolved 10 December 2014
Resolution: Hoses have been replaced.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 December 2013 Resolved
Vessel may conduct offloading operations to remove remaining cargo. After the 10,000 bbls of cargo has been offloading no cargo operations can be conducted until the COI has been completed.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 December 2013
Resolution: Completed inspection, issued COI.
Construction/Loadline › Hull › Longitudinal Frame
Issued 22 January 2010 Resolved
Crop and re-new areas as marked to frame #16 in four starboard void.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 February 2010
Resolved 22 January 2010
Resolution: Distorted areas to frame # 16 were cropped and re-newed.
Construction/Loadline › Hull › Stringer
Issued 22 January 2010 Resolved
Crop and re-new areas as marked to the first stringer from the main deck in the number four starboard void.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 February 2010
Resolved 22 January 2010
Resolution: Distorted areas to stringer were cropped and re-newed.
Construction/Loadline › Hull › Double Hull
Issued 22 January 2010 Resolved
Make permanent repairs to frame number 14, and hull plating between frame numbers 16 and 14 at next dry docking, but NLT 10DEC2013.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 December 2013
Resolved 20 May 2014
Resolution: At the vessel''s drydocking, SECTOR SAN FRAN, and ABS determined that the damage was not bad enough to be repaired.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.