Records from 2008 to 2025. Most recent: inspection, 14 August 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBOLLINGER MARINE FABRICATORS INC · AMELIA, LA, UNITED STATES · built 2008
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry, non-fishing vessel
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Gross Ton
1754 - Simplified, Net Ton
4051 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
14 August 2025
Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8209670
17 July 2024
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7960223
18 September 2023
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7790433
14 August 2023
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7767784
23 March 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7655667
22 August 2022
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7540744
2 November 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7343994
29 July 2021
Periodic Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7272730
21 July 2020
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7012132
3 October 2019
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6831473
30 July 2018
Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6495491
29 August 2017
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6254319
12 July 2016
Internal Structural Exam · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5937611
18 August 2015
Periodic Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5219530
1 June 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5141955
5 August 2014
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4944810
4 September 2013
In-Service Inspection · Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4705422
18 July 2013
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4656867
17 October 2012
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4465932
23 April 2012
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4293540
2 December 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4200490
1 December 2011
Periodic Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4199104
1 August 2011
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4101515
21 February 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3956435
9 December 2010
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3907320
1 December 2009
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3636955
9 July 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3554372
30 March 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3442768
1 June 2008
Administrative Inspection · Initial Certification · Construction Oversight · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3322482
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 17 July 2024
Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station, conspicuously marked, and located at the midpoint of such vessel, or 100 feet from the engine, whichever is the more practical. The remote quick acting manual shutdown shall be installed on the engine so as to provide a quick and effective means of stopping the engine (such as by cutting off the intake air).
Port Cargo Pump Emergency Shutdown was in-op.
46CFR32.50-35
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2024
Resolved 25 July 2024
Resolution: Rcvd evidence of def being rectified.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 17 July 2024
Resolved
Where cargo pump shafts pierce gastight bulkheads, stuffing boxes with readily accessible gastight glands shall be provided.
Starboard cargo pump "stuffing box" (drive shaft through hole) was not vapor tight.
46CFR32.50-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2024
Resolved 25 July 2024
Resolution: Rcvd evidence of def being rectified.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 17 July 2024
Resolved
(a) Each cargo tank of a tank barge must have one of the following liquid overfill protection arrangements:(1) A system meeting the requirements of 46 CFR 39.2007 that—
(ii) Is powered by generators on the barge.
Loss of power alarm did not active when power was secured.
46CFR39.2009(a)(1)(ii)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 25 July 2024
Resolution: Rcvd evidence of def being rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 July 2024
Resolved
There must be ground detection for each:...
Ground detection on Power Panel #2 and Flood light panel was in-op.
46CFR111.05-21
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 25 July 2024
Resolution: Rcvd evidence of def being rectified.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 18 August 2015
Resolved
Each circuit breaker must meet the provisions of 46 CFR 111.53-1. Found circuit breaker in the generator room switchboard not working properly
Due 25 August 2015
Resolved 20 August 2015
Resolution: Received pictures showing that they are working. Please see attached pictures.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 August 2015
Resolved
Each switchboard must be fitted with a drip shield...46 CFR 111.30-5 (b) The switchboard in the generator room was open at the top making it subject to leaks and falling objects.
Due 25 August 2015
Resolved 20 August 2015
Resolution: Received pictures showing that drip shield was installed. Please see attached pictures
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 4 September 2013
Resolved
Ground detection on the 120V panel in port machinery space for flood lights is not operational.
Due 18 September 2013
Resolved 12 September 2013
Resolution: Vessel replace flood lights for the 120V panel located in the port machinery space.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 4 September 2013
Resolved
Outboard generator over speed shutdown could not be verified due to computer controller issues.
Due 18 September 2013
Resolved 12 September 2013
Resolution: Vessel replaced computer module, over speed test was satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 9 December 2010
Resolved
Vessel must test all cargo hoses at 1.5 times the manufacturers rated MAWP.
Action required: 705 - Other - as specified
Due 9 July 2011
Resolved 14 December 2010
Deck/Cargo › Cargo Stowage › General
Issued 1 June 2008
Resolved
Vsl is not authorized to conduct cargo ops until it receives Cargo Authority Attachment
Action required: 705 - Other - as specified
Due 1 October 2008
Resolved 25 September 2008
Resolution: CAA received