RTC 28 is a 2008 tank barge. The Coast Guard has recorded 27 inspections since 2008, most recently in August 2025, along with 10 deficiencies, 1 operational control and 3 casualty investigations between 2009 and 2015.
Records from 2008 to 2025. Most recent: inspection, 14 August 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBOLLINGER MARINE FABRICATORS INC · AMELIA, LA, UNITED STATES · built 2008
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Gross Ton 1754 - Simplified, Net Ton 4051 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 17 July 2024Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station, conspicuously marked, and located at the midpoint of such vessel, or 100 feet from the engine, whichever is the more practical. The remote quick acting manual shutdown shall be installed on the engine so as to provide a quick and effective means of stopping the engine (such as by cutting off the intake air).
Port Cargo Pump Emergency Shutdown was in-op.
46CFR32.50-35
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2024
Resolved 25 July 2024
Resolution: Rcvd evidence of def being rectified.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 17 July 2024Resolved
Where cargo pump shafts pierce gastight bulkheads, stuffing boxes with readily accessible gastight glands shall be provided.
Starboard cargo pump "stuffing box" (drive shaft through hole) was not vapor tight.
46CFR32.50-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2024
Resolved 25 July 2024
Resolution: Rcvd evidence of def being rectified.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 17 July 2024Resolved
(a) Each cargo tank of a tank barge must have one of the following liquid overfill protection arrangements:(1) A system meeting the requirements of 46 CFR 39.2007 that—
(ii) Is powered by generators on the barge.
Loss of power alarm did not active when power was secured.
46CFR39.2009(a)(1)(ii)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 25 July 2024
Resolution: Rcvd evidence of def being rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 July 2024Resolved
There must be ground detection for each:...
Ground detection on Power Panel #2 and Flood light panel was in-op.
46CFR111.05-21
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 25 July 2024
Resolution: Rcvd evidence of def being rectified.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 18 August 2015Resolved
Each circuit breaker must meet the provisions of 46 CFR 111.53-1. Found circuit breaker in the generator room switchboard not working properly
Due 25 August 2015
Resolved 20 August 2015
Resolution: Received pictures showing that they are working. Please see attached pictures.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 August 2015Resolved
Each switchboard must be fitted with a drip shield...46 CFR 111.30-5 (b) The switchboard in the generator room was open at the top making it subject to leaks and falling objects.
Due 25 August 2015
Resolved 20 August 2015
Resolution: Received pictures showing that drip shield was installed. Please see attached pictures
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 4 September 2013Resolved
Ground detection on the 120V panel in port machinery space for flood lights is not operational.
Due 18 September 2013
Resolved 12 September 2013
Resolution: Vessel replace flood lights for the 120V panel located in the port machinery space.
9 July 2009Routine · role: Involved in a Marine Investigation (non-casualty) · activity 3554372
21 February 2011Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 3956435
1 June 2015Routine · role: Involved in a Marine Casualty · activity 5141955
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.