MAURY USCG vessel records Sign in
← All vessels

CMA CGM ORFEO

CMA CGM ORFEO is a 2008 freight ship. The Coast Guard has recorded 37 inspections since 2008, most recently in July 2026, along with 6 deficiencies and 13 operational controls.

Records from 2008 to 2026. Most recent: inspection, 13 July 2026.

Built
2008
Last inspected
13 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9364992 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
950425
Flag
GERMANY
—
Maury page id
psix-950425

Inspections, by type

…with no type recorded22
Years with a record 12 calendar years (2008–2026)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it111249 - Convention (Subpart B), Gross Ton
60767 - Convention (Subpart B), Net Ton
157968 - Displacement, Ton
120897 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SUZANNE MCALLISTER Towing Vessel · MISLE 427544 · 30 September 2022 · activity 7638318ONE HELSINKI Freight Ship · MISLE 1339594 · 30 September 2022 · activity 7638318ROSEMARY MCALLISTER Towing Vessel · MISLE 1407789 · 30 September 2022 · activity 7638318

Inspection history · 37

13 July 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8436849
17 April 2026 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8347272
9 October 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8249844
11 March 2025 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8092051
18 July 2024 PSC B · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7961242
21 February 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7639265
20 February 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7639108
15 February 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7637150
9 December 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7606990
5 December 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7604515
6 October 2022 MARPOL Annex I Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7572854
30 September 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7638318
20 July 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7512237
16 July 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7508052
17 May 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7453627
12 May 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7449017
5 December 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7362607
29 November 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7358455
23 September 2021 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7318341
23 July 2021 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7265464
22 July 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7264649
19 July 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7261464
18 July 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7259447
25 May 2021 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7263030
22 May 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6957913
17 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6954640
14 January 2020 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6888868
14 November 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6855850
14 November 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6859205
30 December 2018 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6603975
1 November 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6572448
24 March 2014 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4819265
12 February 2012 Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4242886
1 July 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3253805
27 May 2008 PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3218215
25 May 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3213677
25 May 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3216858

Deficiency record · 6

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 March 2025 Resolved
A main electric lighting system which shall provide illumination throughout those parts of the ship normally accessible to and used by passengers or crew shall be supplied from the main source of electrical power. PSCO observed two non-operational lightbulbs; one on the starboard "A" deck and one on the starboard "D" deck, that were associated with the emergency lighting system.- 74SOLAS04 II-1/41.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 March 2025
Resolved 12 March 2025
Resolution: Replaced lightbulbs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 1 November 2018 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO IDENTIFIED UNAUTHORIZED/UNNAPROVED REPAIRS TO THE STRUCTURE AND HINGES ON THE STBD LIFEBOAT. 74 SOLAS (14) I/11
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 December 2018
Resolution: rcvd survey statement from DNV-GL stating that all necessary repairs have been made to the satisfaction of class
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2018 Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. THE DESIGN SHALL HAVE REGARD TO MATERIALS USED IN CONSTRUCTION, THE PURPOSE FOR WHICH THE EQUIPMENT IS INTENDED, THE WORKING CONDITIONS TO WHICH IT WILL BE SUBJECTED AND THE ENVIRONMENTAL CONDITIONS ONBOARD. PSCO IDENTIFIED UNAUTHORIZED/UNNAPROVED TEMPORARY MOUNTING SUPPORTS AND ARRANGEMENTS (CHAIN BLOCKS, PIPE STAND, ANGLE IRON BETWEEN MOTORS) INSTALLED ON THE BOILER, THE #1 FUEL OIL BOOSTER PUMP AND THE #2 FUEL OIL BOOSTER PUMP. 74 SOLAS (04) II-1/26
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 December 2018
Resolution: rcvd survey statement from DNV-GL stating that all necessary repairs have been made to the satisfaction of class
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 12 February 2012 Resolved
A second source of energy shall be provided for an additional three starts within 30 minutes. Hydraulic starter for emergency generator inoperative. 74 SOLAS II-I Reg. 44.2
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2012
Resolution: PSCO''s attended vessel and witnessed the successful start of emergency generator with two independent methods.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 12 February 2012 Resolved
Periodically unattended machinery spaces must have special consideration to fire integrity. Wood boxes for spare parts found mounted adjacent to main engine and in purifier room. 74 SOLAS II-2 Reg. 5.2.3.1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 February 2012
Resolved 12 February 2012
Resolution: Removed wood boxes from space.
Engineering › Lubricating Oil Service System › Pump
Issued 27 May 2008 Resolved
Main Engine Crosshead Lubricating pump (#1) is leaking. Solas 74 as amended Ch II-2 Reg 4.1. 70a Rectify deficiencies prior to next US port after sailing foreign
Action required: 705 - Other - as specified
Resolved 3 July 2008
Resolution: RECIEVED CLASS REPORT STATING THAT THE NO 1 MDE PUMP HAS BEEN REPAIR.

Ownership record