Records from 2008 to 2026. Most recent: operational control imposed, 15 April 2026.
Inspection history · 20
14 April 2026
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8349694
14 January 2026
COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8296290
1 October 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8245098
8 January 2025
PSC B · COC-TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8057590
7 January 2024
PSC B · COC-TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7843638
26 April 2019
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6665603
30 April 2018
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6396161
8 September 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6262680
22 June 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6184654
26 February 2017
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6091743
28 July 2016
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5930140
3 November 2015
COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5755582
28 September 2011
COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4154806
26 September 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4155707
8 August 2011
COE-Dockside
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4109222
1 November 2010
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3882041
27 September 2010
ISPS II Exam · Ballast Water Examination · COC-TVE Renew · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3857863
6 November 2008
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3358569
3 November 2008
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3356314
24 October 2008
ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3347146
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 27 September 2010
Resolved
Vessel crew was unable to demonstrate proper operation of the IGG during exam. Conical fitting for IGG is due for overhaul. Vsl has parts needed for due maintenance. Prior to cargo operations in the US vsl crew must demonstrate to the satisfaction of the Classification Society that the IGG is fully operational.
SOLAS (2004 Cons. Ed.) Ch. II-2/ Reg. 4.5.5
Action required: 15 - Rectify deficiencies by next port
Due 28 September 2010
Resolved 1 November 2010
Resolution: Received documentation of completed class survey attesting to satisfactory demonstration of IGG operation.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 24 October 2008
Resolved
Vsl has a leak/ fractured weld seam in stool space between 2P, and 2S tanks, allowing cargo to leak into 2S segregated ballast tank. Ballast isolated to slop tank, stool space inerted, repair plan awaiting class approval. Repair plan to be approved at next port of call.
Action required: 705 - Other - as specified
Resolved 6 November 2008
Resolution: Received class report attesting to the repairs of the cargo tanks.