Inspection history · 56
13 June 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8403315
24 October 2024
MTSA/ISPS Verification · Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8021153
22 May 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7917274
14 May 2024
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7921858
13 May 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7933661
12 May 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7911772
25 April 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7901449
15 April 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7895573
9 April 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7892622
13 March 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7878720
26 February 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7871365
23 February 2024
Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7859372
9 October 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7805715
5 June 2023
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7751196
24 March 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7666908
20 January 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7625932
27 December 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7613626
26 October 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7584194
28 September 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7583558
22 April 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7436104
4 December 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7106668
21 October 2020
MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7082041
11 August 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7030425
8 February 2020
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6906097
8 February 2020
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6909457
25 November 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6862441
5 August 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6774067
18 January 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6617674
16 January 2019
Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6611368
12 July 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6477201
8 September 2017
MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6256445
9 April 2017
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6121699
3 February 2017
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6082577
23 January 2017
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6075664
24 November 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6046990
23 November 2016
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6046904
27 August 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5988133
18 June 2016
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5911448
12 May 2016
Administration
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5880779
26 April 2016
Industry Initiated Exam · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5870093
27 March 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5841776
9 December 2015
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5778617
13 November 2015
MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5784554
16 August 2015
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5218906
14 July 2015
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5199188
18 May 2015
Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5128664
22 November 2013
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4759695
23 May 2013
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4599043
21 November 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4192690
13 June 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4045327
27 January 2011
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3934966
27 January 2011
Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3936188
13 December 2010
Industry Initiated Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3909561
21 January 2010
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3671395
18 November 2009
Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3635638
21 April 2009
MTSA/ISPS Verification · Initial Certification · Construction Oversight · MARPOL Annex VI Survey · Uninspected Other
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3572958
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 June 2026
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection agains hazards to life, property, and the environment.
OMO notified OCMI of a leak in the fire main between frames 23 and 25 in the overhead of the main deck galley. Permanently repair or replace the affected section of piping and test the repair to the satisfaction of the third-party organization (TPO). Upon satisfactory completion, provide this office with a report from the TPO documenting the repair and test results.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 June 2026
Resolved 13 June 2026
Resolution: OMO provided report from TPO attesting to the satisfactory repair and test of renewed firemain piping.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 February 2024
Resolved
Remote fuel shutoff valve for emergency generator installed in fuel piping directly outside fuel supply tank found not able to be operated from a safe place outside the space where valve is installed. VESSEL WILL REPAIR DURING NEXT DRY DOCK,
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 February 2024
Resolved 24 October 2024
Resolution: Received ABS survey report no. 6517829, that assigns finding no. 490 to this issue and attests remote fuel shutoff was installed and tested to the satisfaction of the attending ABS surveyor.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 February 2024
Resolved
Fire pump to support the fire monitor found to be leaking 2-3 gallons/minute
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2024
Resolved 1 March 2024
Resolution: O/O sent a video of fire monitor pump tested. No leak detected
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 23 February 2024
Resolved
External shut down to emergency diesel generator found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 February 2024
Resolved 23 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 October 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons under normal and emergency conditions. Vessel's Port generator is currently not operational.
46CFR143.205
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2023
Resolved 13 October 2023
Resolution: Vessel provided satisfactory ABS report
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 27 December 2022
Resolved
Operate a ballast water management system that has been approved by the Coast Guard under 46CFR part 162. Ballast water treatment system is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 January 2023
Resolved 2 January 2023
Resolution: Replaced bypass filter, set limit switches on bypass valve, replaced air valves for setting speed and corrected position. Unit tested all. SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 February 2020
Resolved
46 CFR 143.605 / 10c - During the vessel's transit to Port Angeles, Wa, vessel experienced a loss of propulsion as a result of overspeed alarms and shutdowns of both main propulsion engines. It was determined that the propulsion machinery operated as designed and that both main engines restarted following normal procedures. An official statement by the Chief Engineer and copies of the engineering and brdige log book were required to verify that all systems operated as designed. Vessel cleared to sail.
Action required: 10 - Deficiency Rectified
Due 8 February 2020
Resolved 8 February 2020
Resolution: System confirmed as operating as designed. Vessel cleared to sail.
Engineering › Diesel Engine (propulsion-direct drive) › Connecting Rod
Issued 21 November 2011
Resolved
Port Engine bridge control Inoperable. Vessel rep must have repairs conducted prior to departing port of Tampa.
Action required: 705 - Other - as specified
Due 21 November 2011
Resolved 21 November 2011
Operations/Management › Pollution › Control of NOx
Issued 28 October 2009
Resolved
IAW MARPOL Annex VI - Provide EPA issued EIAPP for the (03) Caterpillar generators to the satisfaction of USCG MSD Sturgeon Bay within 90 days.
Action required: 705 - Other - as specified
Due 28 January 2010
Resolved 18 November 2009
Resolution: Rec''d electronic copy of EIAPPs for the 03 Caterpillar gen sets from Marinette Marine Corp rep [name withheld]