MAURY USCG vessel records Sign in
← All vessels

HTCO 3073

HTCO 3073 is a 2009 tank barge. The Coast Guard has recorded 20 inspections since 2010, most recently in March 2026, along with 5 deficiencies and 3 casualty investigations between 2012 and 2016.

Records from 2010 to 2026. Most recent: inspection, 2 March 2026.

Built
2009
Last inspected
2 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1035626
Flag
UNITED STATES
—
Maury page id
psix-1035626

Inspections, by type

…with no type recorded3
Years with a record 13 calendar years (2010–2026)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2009
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 November 2025 · expires 31 December 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

Inspection history · 20

2 March 2026 Bulk Liquid Transfer Monitor
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8318782
10 March 2025 MTSA Verification · COI Inspection · Internal Structural Exam · Drydock Exam · Cargo Tank Internal · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8087824
20 March 2024 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7882606
30 March 2022 Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7421408
12 December 2019 Examination of Repairs · Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6862709
20 September 2018 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6544567
16 October 2017 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6288253
1 September 2016 Administrative Inspection · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5989365
20 June 2016 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 5913025
10 September 2015 Examination of Repairs · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5720856
1 September 2015 MTSA Verification · Damage Survey · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5232407
26 November 2014 Cargo Tank Internal · MTSA Verification · Internal Structural Exam · Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5026543
7 January 2014 Annual Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4779549
21 December 2012 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4503522
14 May 2012 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4312067
20 January 2012 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4228563
19 January 2012 Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4227500
13 January 2012 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4224130
1 September 2011 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4132883
10 August 2010 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3819249

Deficiency record · 5

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 20 September 2018 Resolved
Cargo hoses are required to be hydro tested annually. The 8" hose for oil service S/N 16570 hydro is out of date. Remove hose from service.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2018
Resolved 20 September 2018
Resolution: Hose was removed from barge.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 20 September 2018 Resolved
Vapor hoses are required to be hydro tested annually. The 8" vapor hose S/N CHTX 1116 hydro is expired. Remove hose from service.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2018
Resolved 20 September 2018
Resolution: Vapor hose was removed from barge.
Construction/Loadline › Hull › Hull Plating
Issued 1 September 2015 Resolved
Found 26" long X 5" deep inset on the headlog centerline. Issued 835 to have repairs made after discharge.
Condition: Damaged By Earlier Event
Due 1 October 2015
Resolved 10 September 2015
Resolution: Cropped and renewed one 2' x 3' section of slope sheet and one 3.5' x 5' section of headlog plate. Air/Soap test all sat.
Deck/Cargo › Cargo Heating › General
Issued 21 December 2012 Resolved
Conduct periodic test of thermal fluid heater as per use.
Action required: 705 - Other - as specified
Due 26 November 2014
Resolved 26 November 2014
Resolution: Attended vessel with rep from Volcanic. Witnessed operational test of thermal fluid heater as well as all required alarms. Test SAT.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 20 January 2012 Resolved
Vessels emergency shutdown was inoperable and mufflers were leaking . Vessel was required to make repairs to shut down and replace muffler.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 20 January 2012
Resolution: Vessel has made repairs to shut down and replaced muffler.

Casualty record · 3

13 January 2012Routine · role: Involved in a Marine Casualty · activity 4224130
14 May 2012Routine · role: Involved in a Marine Casualty · activity 4312067
20 June 2016Routine · role: Involved in a Marine Casualty · activity 5913025
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.