Records from 2006 to 2026. Most recent: inspection, 22 January 2026.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · MADISONVILLE, LA, UNITED STATES · built 2006
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 28
22 January 2026
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8300939
1 July 2025
Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8172354
5 June 2025
Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8152964
14 May 2025
Damage Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8136100
14 May 2025
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8225291
21 June 2024
MTSA Verification · Internal Structural Exam · Drydock Exam · Cargo Tank Internal · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7933902
1 July 2020
Administrative Inspection · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6992638
9 August 2018
MTSA Verification · Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6505656
10 July 2018
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6474502
16 October 2017
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6288257
18 July 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5938094
29 June 2015
Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5168071
18 June 2015
Internal Structural Exam · MTSA Verification · COI Inspection · Examination of Repairs · Drydock Exam · Administrative Inspection · Cargo Tank Internal
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5156773
9 February 2015
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5064690
31 January 2014
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4791952
7 January 2014
Annual Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4779531
21 December 2012
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4503805
14 May 2012
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4312067
20 January 2012
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4520801
13 January 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4224130
3 January 2011
Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3916481
27 August 2010
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3834359
15 October 2008
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3345219
30 September 2008
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3335870
5 September 2007
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3050122
6 November 2006
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2815396
20 September 2006
Construction Oversight · Internal Structural Exam · Initial Construction-Excluding Oversight · MTSA Verification · Hull Examination · COI Inspection · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2751199
15 June 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2680328
14 - Pollution Prevention › 142 - MARPOL Annex II › Vent. Procedures/equipment
Issued 10 July 2018
Resolved
There is a pinhole leak in the cargo vapor line. Temp repairs completed using rubber patch with epoxy underneath.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 14 August 2018
Resolution: cropped and renewed approximately 200 feet of logitudal vapor line with one tranverse flange to vapor drop only using shipyard furnished material. Crop and renew two 18" x 8" inserts on the tranverse header in kind. Conducted a visual exam of all repairs
Electrical › Electric Supply System (service) › Transformer
Issued 21 December 2012
Resolved
Transformer to the left of the switchboard shall be replaced prior to use of generator. Transformer's top was heavily corroded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 July 2015
Deck/Cargo › Cargo Heating › General
Issued 21 December 2012
Resolved
Thermal fluid heater must be tested prior to use in the presence of a Coast Guard marine inspector.
Action required: 705 - Other - as specified
Resolved 23 July 2015
Resolution: Added endorsement to COI
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 20 September 2006
Resolved
Provide original or certified copy of COFR to attending marine inspector. 33 CFR 138.65
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2006
Resolution: Proof of COFR found in MISLE, copy to be placed in Activity # 2815396.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 20 September 2006
Resolved
Provide proof of Cargo Transfer Procedures onboard to the attending marine inspector. 33 CFR 155.720
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2006
Resolution: Cargo Transfer Procedures onboard.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 20 September 2006
Resolved
Provide proof of Vessel Responce Plan onboard vessel as per 33 CFR 155.1030
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2006
Resolution: Approved Vessel Response Plan onboard.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 20 September 2006
Resolved
Provide proof of properly installed Class 1 Div. 1 wiring harness on Cargo Pump engine. 46 CFR 111.105-31
Action required: 705 - Other - as specified
Due 1 December 2008
Resolved 27 October 2009
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 20 September 2006
Resolved
Install [name withheld] indicating devices (rising sticks). 46 CFR 39.20-3
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2006
Resolution: High level indicating devices (rising sticks) installed on barge.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 September 2006
Resolved
Paint or mark Benzene regulated areas as per 46 CFR 197.535
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2006
Resolution: Painted and marked Benzene regulated area on barge.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 20 September 2006
Resolved
Provide proof of Benzene Monitoring Program as per 46 CFR 197 subpart C and NAVIC 6-92
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2006
Resolution: Benzene Monitoring Program information will verified with fax scanned to Activity # 2815396.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 20 September 2006
Resolved
Label overfill alarm connection. 46 CFR 39.20-7
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2006
Resolution: Overfill alarm connection labeled.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 20 September 2006
Resolved
Install exhaust blanket on generator exhaust piping. 46 CFR 58.10-5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2006
Resolution: Exhaust blanket installed on generator exhaust piping.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 20 September 2006
Resolved
Install non-conductive deck covering in front of the switchboard in the Thermal Fluid Heater house. 46 CFR 111.30-11
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2006
Resolution: Non-Conductive deck covering installed in from of thermal fluid heater switchboard.
Deck/Cargo › Cargo Heating › General
Issued 20 September 2006
Resolved
Install insulated incombustable material on cargo header pipe and all other heated pipes exposed to personnel as required in 46 CFR 36.05-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2006
Resolution: Installed insulated incombustable material on cargo header pipe.