Records from 1999 to 2024. Most recent: inspection, 28 March 2024.
Documentation record
Registered dimensions (L × B × D)72.0 ft × 30.0 ft × 10.0 ft
Registered tonnagegross 144 / net 115
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHOPE SERVICES INC · DULAC, LA, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 August 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it115 - Simplified, Net Ton
144 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 34
28 March 2024
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7886624
26 January 2023
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7627599
25 January 2022
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7385561
30 June 2021
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7240507
16 January 2020
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6891545
19 November 2018
Administrative Inspection · Initial Certification · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6583761
16 October 2018
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6562687
26 May 2017
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6162811
20 June 2016
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 5913025
28 August 2015
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5231994
22 April 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4851619
22 April 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4851633
19 November 2013
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4767526
27 November 2012
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4492161
18 August 2011
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4119325
8 February 2011
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3942369
29 November 2010
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3900985
1 December 2009
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 3642788
17 December 2007
Damage Survey · Uninspected Other · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3116943
17 August 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3030799
21 April 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2339668
13 January 2005
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2275541
4 January 2005
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2268743
17 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1966209
26 August 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2013596
23 April 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1787770
4 August 2002
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1658429
23 May 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1624044
23 May 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1667517
31 January 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 102837
31 January 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 274543
17 September 1999
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 113212
24 May 1999
Uninspected Towing Vessel
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 799454
2 March 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 426176
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 March 2024
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery space. The starboard generator main seal is broken. Replace the main seal during next maintenance period within 3 months.
46 CFR 143.220(a)
Action required: 705 - Other - as specified
Due 18 July 2024
Resolved 22 April 2024
Resolution: Cummins rep installed new, longer vent tubes for port and starboard generators.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2024
Resolved
Piping for flammable or combustible liquid must be fitted with isolation valves that are clearly marked by labeling or color coding that enables the crew to identify its function. Port and starboard fuel tanks do not have isolation valves at top of tank. Install isolation valve on both fuel tanks.
46 CFR 143.250(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2024
Resolved 22 April 2024
Resolution: High level alarm isolation valves installed on each port/stbd fuel tank.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 March 2024
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. The electrical panel in the forward engine room was not labeled. Label the electrical panel with detail regarding what each breaker serves.
46 CFR 143.400(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2024
Resolved 22 April 2024
Resolution: Installed labeling on electrical panel detailing which load is served.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 28 March 2024
Resolved
As far as practicable, the owner or operating manager must implement safety control measures to include engineering, source modification. The steering gear systems expands beyond protective grating on the stern. Paint on the deck informing crew members to stay clear of the area has faded. Repaint the safety zone to ensure personnel keep out of steering gear zone when equipment is in use.
46 CFR 140.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2024
Resolved 22 April 2024
Resolution: Repainted area on deck identifying steering gear safety zone.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 June 2021
Resolved
Vessel must complete a TSMS audit
Action required: 705 - Other - as specified
Due 30 December 2021
Resolved 28 January 2022
Resolution: Audit was conducted and reviewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 November 2018
Resolved
Remove 75' fire hoses and replace with 50' fire hoses.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 19 February 2019
Resolved 19 February 2019
Resolution: Vessel removed 75' fire hoses and replaced with 50'.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 November 2018
Resolved
During a TSMS option no decal inspection the engine room did not have an approved B-V extinguisher. Equip the engine room with an approved 160-B semi portable fire extinguisher to the satisfaction of the Third Party Organization and provide a report of satisfactory to the Coast Guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2019
Resolved 28 March 2019
Resolution: Received objective evidence from TPO excepting semi portable fire extinguisher and its arrangement.