NORWEGIAN BREAKAWAY

NORWEGIAN BREAKAWAY is a 2013 passenger vessel (inspected). The Coast Guard has recorded 49 inspections since 2016, most recently in May 2026, along with 27 deficiencies and 4 operational controls.

Records from 2016 to 2026. Most recent: inspection, 17 May 2026.

Built
2013
Last inspected
17 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9606912
1116411
Flag
BAHAMAS, THE
Maury page id
psix-1116411

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded20
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it145655 - Convention (Subpart B), Gross Ton
132549 - Convention (Subpart B), Net Ton
13500 - Dead Weight, Metric Ton
69800 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

EMILY A HEBERT Towing Vessel · MISLE 16970 · 26 March 2017 · activity 6111971DOUBLE SKIN 304 Tank Barge · MISLE 874065 · 26 March 2017 · activity 6111971QUANTICO CREEK Towing Vessel · MISLE 1077107 · 26 March 2017 · activity 6111971

Inspection history · 49

17 May 2026 PSC B · COC-CVE Quarterly
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8361658
19 December 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8285761
19 December 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8306045
15 December 2025 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8283742
15 December 2025 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8306085
12 December 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8282398
22 November 2025 PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8272525
26 May 2024 PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7919004
28 November 2023 Deficiency Check · PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7830170
19 March 2023 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7653566
5 March 2023 COC-CVE Quarterly · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7643057
20 September 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7563010
11 September 2022 COC-CVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7555969
7 September 2022 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7560481
26 August 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7543941
3 August 2022 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7524137
3 August 2022 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7539447
2 March 2022 COC-CVE Quarterly · Ballast Water Examination · ISPS Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7404481
21 September 2021 COC-CVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7316695
6 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dpw) · USCG Southeast District (CGD-SE) · Activity 6936095
13 October 2019 ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6832821
11 August 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6779756
19 May 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6687722
14 April 2019 COC-CVE Quarterly · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6658851
25 January 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6950770
16 October 2018 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6559864
30 March 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6388155
2 March 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6386052
16 February 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6386015
5 December 2017 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6318505
3 December 2017 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6317083
18 November 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6309414
7 November 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6305749
19 October 2017 ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6290893
12 September 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6266294
7 September 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6261886
20 April 2017 COC-CVE Annual · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6129061
27 March 2017 Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6112163
26 March 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6111971
3 March 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6107959
12 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6056625
21 October 2016 ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6027078
13 August 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6014906
7 August 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5970807
31 July 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5960319
24 July 2016 NPV Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5950879
24 April 2016 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5860309
20 March 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5836969
6 March 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5828347

Deficiency record · 27

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 December 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Received report of port azipod operating at reduced capacity.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 January 2026
Resolution: Documentation received, deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 December 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Received report of port azipod operating at reduced capacity.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 December 2025
Resolved 19 December 2025
Resolution: DEF CLOSED to allow vessel entry for repair part retrieval. SAFETY COTP ORDER 071-25 REDUCTION IN PROPULSION ISSUED while vessel is in port. See Ops Control Activity 8285761.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 November 2023 Resolved
The means of escape, including stairways and exits, shall be marked ... The marking must enable passengers to identify the routes of escape and readily identify the escape exits. The route of escape signs for crew egress near B-04-04-007 and B-04-05-040 lead back into crew areas instead of a stairway, cooridor or open deck space. Route of escape sign near door 6-4-16 leads to a locked door. Route of escape is not indicated on the Fire Control Plan. 74 SOLAS 20 II-2/13.3.2.5.1 (16ac)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 11 December 2023
Resolution: Class report attesting to removal of sign in question provided and attached to this activity.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 November 2023 Resolved
Lifejackets shall be so placed as to be readily accessible and their positions shall be plainly indicated. Assessible cabin (ADA) lifejacket location is marked on lower level of closet and underneath the bed, but the lifejackets were stored only under the bed. 74 SOLAS 20 111/7.2.2 (16ac)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 11 December 2023
Resolution: Class report attesting to corrective action provided and attached to this activity.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 November 2023 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. Fire doors 13-5-004, 13-4-008, 13-3-008, 13-2-005, 13-1-003, 11-2-006, 11-1-002, 10-1-004, 10-3-003, 10-3-002, 10-3-009 closed in less than 10 seconds. 74 SOLAS 20 11-2/9.4.1.1.5.2 (16ac)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 11 December 2023
Resolution: Class report attesting to adjustment and validation of proper operation per SOLAS provided and attached to this activity.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 November 2023 Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the d ivisions. Fire doors 11-2-004 did not close properly. 74 SOLAS 20 11-2/9.4.1.2.1 (16ac)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 11 December 2023
Resolution: Class report attesting to adjustment and validation of proper operation per SOLAS provided and attached to this activity.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 November 2023 Resolved
The construction of doors and door frames in 'A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. Fire doors 13-5-004, 13-3-003, 13-3-002, 11-1-002, 10-5-005 did not close properly. 74 SOLAS 20 11-2/9.4.1.1.2 (16ac)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 11 December 2023
Resolution: Class report attesting to adjustment and validation of proper operation per SOLAS provided and attached to this activity.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 November 2023 Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. Twist locks that were not integrated into the release latch were observed in escape routes in the following areas: Entourage Lounge leading to arcade, the humidor, and the Ice Bar. 74 SOLAS 20 I-2/13.3.2.6.2 (10c)
Action required: 10 - Deficiency Rectified
Resolved 11 December 2023
Resolution: Class report attesting to adjustment and validation of proper operation per SOLAS provided and attached to this activity.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 5 March 2023 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Port side rescue boat crew are unfamiliar with procedure for lowering rescue boat. 74 SOLAS 20 111/19.2.1 Code 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2023
Resolved 5 March 2023
Resolution: Cleared on the spot. PSCOs allowed Safety Officer to give more training to the rescue boat crew and then successfully witnessed a lowering of the rescue boat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 March 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboat Number 9 port engine is inoperable. 74 SOLAS 20 111/20.2 Code 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2023
Resolved 4 April 2023
Resolution: SEC NOLA received a class report from DNV which satisfies the requirement of this regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 March 2023 Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All life-saving appliances shall be fitted with retro-reflective material where it will assist in detection. Lifeboats number 6 and 10 have wasted/missing retroreflective material. 74 SOLAS 20 111/34 LSA Code 1.2.2.7 Code 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2023
Resolved 19 March 2023
Resolution: PSC NOLA received a class report from DNV satisfying the requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2023 Resolved
Lifejacket lights and whistles shall be selected and secured to the lifejacket in such a way that their performance in combination is not degraded. The crew damaged the lifejackets while installing new lifejacket lights. 74 SOLAS 20 111/34 LSA Code 2.2.1.15 Code 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2023
Resolved 19 March 2023
Resolution: PSC NOLA received a class report from DNV satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 March 2023 Resolved
The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. Escape route in Meat Freezer Deck 4, MVZ 6, was obstructed by pallets. 74 SOLAS 2011-2/13.1.2 Code 10c
Action required: 10 - Deficiency Rectified
Due 5 March 2023
Resolved 5 March 2023
Resolution: Crew moved the pallets blocking the escape route.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2023 Resolved
The test procedure includes a visual inspection of the steering gear and its connecting linkage, and, where applicable, the operation of the following: (v) each remote steering gear control system power failure alarm. (vi) each remopte steering gear power unit failure alarm. During steering test, the crew did not conduct or witness anyof the required audible alarms. 33CFR164.25(a)(1) 10c
Action required: 10 - Deficiency Rectified
Due 5 March 2023
Resolved 5 March 2023
Resolution: PSCO's had the ships crew redo the steering test and verified the testing of the loss of power to the steering/azipod pumps.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 March 2023 Resolved
Spaces are classified according to their fire risk as shown in categories (1) to (14). NC Machinery space on desk 6, MVZ 7 is a category (10) space where storage of combustibles is prohibited. PSCO observed storage of multiple cardboard boxes containing NC parts in Space O6/E68. 74 SOLAS 20 11-219.2.2.3.2.2 Code 10c
Action required: 10 - Deficiency Rectified
Due 5 March 2023
Resolved 5 March 2023
Resolution: The vessels crew removed the common combustible stores from the space.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 September 2022 Resolved
74SOLAS20 II-2/13.3.2.6.2 Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. The "Under Two Zoo", "Entourage", and fitness room escape doors were not fitted with a means of quick release on the locking mechanism.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 26 October 2022
Resolution: under appeal
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 September 2022 Resolved
74 SOLAS 97 II-2/13.3.2.5.1 Escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. Massage rooms in spa lacked exit marking. Interior staricase within Haven space lacked exit marking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 26 October 2022
Resolution: under appeal
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 September 2022 Resolved
74 SOLAS 20 II-2/9.2.2.3.4.5 The sauna doors shall open outwards by pushing. Sauna doors open inward.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 12 October 2022
Resolution: Resolved via pictures/class report.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 September 2022 Resolved
74 SOLAS 20 II-2/9.2.2.3.4.6 Electricity heated ovens shall be provided with a timer. Sauna oven does not have a timer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 12 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 August 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel experienced a loss of propulsion on starboard azipod unit; after following the resets to the starboard propulsion, the power was restored to the B drive only, operating at 50% of its capacity.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 19 August 2022
Resolution: Class survey was sent to San Juan and Sector [name withheld] stating the satrboard azipod had been fixed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will reamin fit to proceed to without danger to the ship or persons on board. PSCO observed several soft patches in the black water piping located on deck 4, zone 2. Repair to original design.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 March 2022
Resolution: Received a class report attesting to the correction of the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022 Resolved
All electrial apparatus shall be so constructed and so installed as not to casue injury when handled or touched in the normal manner. PSCO observed exsposed outlet in barber ship and dead end cable hanging in technical space of salt bath area.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 March 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 March 2022 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the requirements outlined in SOLAS74(a) 2020 II-2/9.4.1.1.5. PSCO obsrved several doors unable to close properly (B-15-2-013/014.018)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 March 2022 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed several crew members assigned with emergency duties not familiar with vessel procedures. Crew member with assigined duties to undergo training prior to departure.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 6 March 2022
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 21 September 2021 Resolved
The following fire protection system shall be kept in good working order so as to ensure their required performance if a fire occurs including fire resisting divisions. Drawers under cooktops impeded the full closure of the fire dampers in multiple galleys. 74 SOLAS (20) II-2/14.2.1.1, 10a
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 21 September 2021
Resolution: Class surveyor onboard agreed with def and arranged for interim repairs while issuing a condition of class, full survey of all dampers to be conducted and permanent repair solution to be found.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 October 2019 Resolved
FIRE DOORS IN MAIN VERTICAL ZONE BULKHEADS, GALLEY BOUNDARIES AND STAIR WAY ENCLOSURES OTHER THAN POWER-OPERATED WATERTIGHT DORRS AND THOSE WHICH ARE NORMALLY LOCKED SHALL SATISFY THE FOLLOWING REQUIREMENTS: SHALL BE SELF CLOSING. DOORS FD-06-6-003, FD-045-009, FD-04-2-024, FD-04-2-020, FD-04-4-003, FD-04-6-003, FD-02-6-002, AND FD-02-2-008 WERE UNABLE TO PROPERLY CLOSE. 74SOLAS(14CONS.)II-2/ 9.4.1.1.5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2019
Resolved 23 October 2019
Resolution: RO issued statement attesting to the proper operation of the aforementioned fire doors. deficiency cleared 23OCT2019
Construction/Loadline › Hull › Hull Plating
Issued 27 March 2017 Resolved
Ships shall be designed, constructed and maintained in compliance with the structural requirements of a classification society. Bunkering barge collided with vessel during operations, vessel suffered smooth inset on port midships area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2017
Resolution: Reviewed and accepted class report from DNV-GL. report attached to activity.