Records from 2012 to 2025. Most recent: inspection, 2 October 2025.
Documentation record
Registered dimensions (L × B × D)576.0 ft × 105.6 ft × 61.7 ft
Registered tonnagegross 29,242 / net 11,926
ITC dimensions (L × B × D)576.0 ft × 105.6 ft × 61.7 ft
ITC tonnagegross 29,242 / net 11,926
BuilderAKER PHILADELPHIA SHIPYARD INC · PHILADELPHIA, PA, UNITED STATES · built 2012
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 2 December 2025 · expires 31 January 2027
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29242 - Convention (Subpart B), Gross Ton
11926 - Convention (Subpart B), Net Ton
46697 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 40
2 October 2025
Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8245256
10 September 2025
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8231439
3 February 2025
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8073558
31 January 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8072653
22 October 2024
Annual Inspection · Deadweight Survey · ACP Annual Oversight · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8022692
17 April 2024
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7923601
14 February 2024
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7865704
27 October 2023
ACP Annual Oversight · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7812059
2 October 2023
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7801723
20 September 2023
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7794958
25 July 2023
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7753593
21 January 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7624978
25 December 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7612944
26 November 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7614623
26 November 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7623910
26 November 2022
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7632945
9 November 2022
ACP COI Oversight · COI Inspection · Re-Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7590463
28 October 2022
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7585213
23 August 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7541425
14 October 2021
Deficiency Check · Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7328619
6 October 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7327706
30 October 2020
Periodic Inspection · ACP Periodic Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7087342
29 May 2020
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6963597
29 May 2020
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6983744
30 September 2019
MTSA/ISPS Verification · Annual Inspection · Ballast Water Examination · ACP Annual Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6816522
27 November 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6593075
19 November 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6583673
1 October 2018
MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6552142
23 January 2018
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6342178
17 January 2018
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6340040
24 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6294478
11 September 2017
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6262609
23 August 2017
MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6249655
7 February 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6084095
18 October 2016
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6025099
4 October 2016
Annual Inspection · Administrative Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6015867
12 August 2015
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5213958
5 August 2015
ACP Annual Oversight
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5206422
30 October 2014
DAPI Audit · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5059930
23 May 2012
MTSA/ISPS Verification · ACP Handover Survey · Construction Oversight · Initial Certification · ACP COI Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4319987
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 22 October 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
Lifeboat window bolts were overtightened cracking windows in several spots. Additionally, seal between lower hull and topside was deteriorated across the stern
74SOLAS (20) III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 November 2024
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 27 October 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship on all respects will remain fit to proceed to sea without danger to the ship or persons on board. The cargo pilot line on the # 3 Port Framo pump ruptured during discharge operations. MI observed the crew activate ESD during an actual emergency. Vessel must secure the # 3 Port pump remote activation hydraulic line and blank-off the connection at the pump.
74 SOLAS (14) I/ 11(a)
705 (A)
Action required: 705 - Other - as specified
Due 27 October 2023
Resolved 28 October 2023
Resolution: Accepted by ABS: See Work Order: 6100174.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 October 2021
Resolved
When a distribution system, whether primary or secondary, for power, heating or lighting, with no connection to earth is used, a device capable of continuously monitoring the insulation level to earth and of giving an audible or visual indication of abnormal low insulation values shall be provided. At the time of the inspection, it was noted that a partial ground was found on the "B" phase of the 440VAC distribution panel. SOLAS09 II-I/Reg.45.4.2
Action required: 15 - Rectify deficiencies by next port
Due 28 October 2021
Resolved 25 October 2021
Resolution: Received, reviewed, and accepted ABS report # 4994290. ABS has made note and provided finding number for this deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 6 October 2021
Resolved
Ships shall be provided with arrangements, equipment and fittings of sufficient safe working load to enable the safe conduct of all towing and mooring operations associated with the normal operation of the ship. The crew reported a punctured hydraulic pipe used for mooring equipment on the main deck which was observed leaking hydraulic oil when under pressure. The piping is not in compliance with the classification society standards and poses a potential pollution threat. A temporary steel doubler was welded over the punctured piping until the pipe can be replaced in kind.
SOLAS 2009 Cons. II-1 3-8.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2021
Resolved 7 October 2021
Resolution: ABS issued a condition of class for temporary repairs on October 7, 2021. Final repairs to the piping were completed on October 14, 2021 and NDT testing witnessed by ABS surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 May 2020
Resolved
IN ADDITION TO THE REQUIREMENTS CONTAINED ELSEWHERE IN THE PRESENT REGULATIONS, SHIPS SHALL BE DESIGNED, CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY WHICH IS RECOGNIZED BY THE ADMINISTRATION IN ACCORDANCE WITH THE PROVISIONS OF REGULATION XI-1/1, OR WHITH APPLICABLE NATIONAL STANDARDS OF THE ADMINISTRATION WHICH PROVIDE AN EQUIVALENT LEVEL OF SAFETY. VESSEL MAIN ENGINE IS UNABLE TO BE RUN IN REVERSE. PRIOR TO DEPARTURE FROM ANCHORAGE, PROVIDE CLASS REPORT ATTESTING TO THE PROPER OPERATION OF THE MAIN ENGINE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2020
Resolved 29 May 2020
Resolution: Vessel provided ABS class report detailing repairs to the satisfaction of the reviewing Marine Inspector. Cleared.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 17 January 2018
Resolved
Prove proper operation & reliability of the vessel's engine order telegraph. Machinery space to remain manned in accordance with minimally attended machinery space/ACC levels with live watch until rectified.
Action required: 705 - Other - as specified
Due 24 January 2018
Resolved 23 January 2018
Resolution: Received satisfactory report from classification society confirming permenant repairs.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 August 2017
Resolved
Unable to complete inspection due to pending hurricane approaching inspection location. See narrative for remainder of CG-835.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2017
Resolved 24 October 2017
Resolution: Recieved documentation from Vsl Rep of cleared CG-835 on 11 Sept by an attending inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 October 2016
Resolved
THE FIRE INTEGRITY OF THE DIVISIONS SHALL BE MAINTAINED AT OPENINGS AND PENETRATIONS. NUMEROUS MCTs THROUGHOUT THE CABLE TRUNK ON ALL DECKS WERE NOT PROPERLY SEALED. SOLAS II-2/9.1.3
Action required: 705 - Other - as specified
Due 6 November 2016
Resolved 13 October 2016
Resolution: Received Statutory Deficiency document from ABS Surveyor [name withheld], via email.
Lifesaving › Lifebuoys › Stowage
Issued 6 October 2016
Resolved
THE SELF-IGNITING LIGHT MAY NOT BE ATTACHED TO THE LIFEBUOYS REQUIRED BY THIS SECTION TO BE FITTED WITH LIFELINES. 46 CFR 199.70(a)(3)(ii).
Action required: 705 - Other - as specified
Due 6 November 2016
Resolved 13 October 2016
Resolution: Received Statutory Deficiency document from ABS Surveyor [name withheld], via email.
Operations/Management › Drills/Instruction › Not Conducted
Issued 30 August 2012
Resolved
Conduct fire, abandon ship, and security drills to the satisfaction of the attending USCG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2012
Resolution: Witness satisfactory abandon ship, fire, and security drill.