TEXAS ENTERPRISE

TEXAS ENTERPRISE is a 1981 freight ship. The Coast Guard has recorded 50 inspections since 2016, most recently in May 2021, along with 42 deficiencies, 4 operational controls and 34 casualty investigations between 2002 and 2020.

Records from 2002 to 2021. Most recent: inspection, 18 May 2021.

Built
1981
Last inspected
18 May 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 May 2021
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7821154
Flag
HONG KONG
Maury page id
psix-52594

Documentation record

Tonnage as PSIX records it21734 - Convention (Subpart B), Gross Ton
12120 - Convention (Subpart B), Net Ton
36476 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ALASKA Industrial Vessel · MISLE 77764 · 27 November 2018 · activity 6593075PENNSYLVANIA Tank Ship · MISLE 1171586 · 27 November 2018 · activity 6593075

Inspection history · 50

18 May 2021 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7200201
9 March 2021 In-Service Inspection · Administrative Inspection · TPO Audit
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7152662
28 September 2020 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7069309
23 September 2020 ACP Annual Oversight · ACP Additional Oversight – Risk Assessment · Annual Inspection · Ballast Water Examination · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7063664
27 August 2020 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7043809
21 August 2020 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7038927
9 August 2020 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7027560
8 June 2020 Administrative Inspection · ACP Additional Oversight – Risk Assessment
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6971018
18 May 2020 MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6955397
17 September 2019 MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6814295
28 March 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6651239
6 March 2019 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6637111
6 March 2019 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6637152
21 February 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6632602
3 December 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6590826
27 November 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6593075
13 November 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6580046
12 October 2018 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6560262
9 October 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6558415
7 June 2018 ACP Additional Oversight – Risk Assessment · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6438164
1 May 2018 Annual Inspection · ACP Additional Oversight – Risk Assessment
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6403840
1 May 2018 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6531717
25 April 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6399612
23 April 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6397661
23 January 2018 ACP Additional Oversight – Risk Assessment · Internal Structural Exam · Drydock Exam
Physical examination · Activities Europe · Activity 6341932
24 October 2017 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6293872
14 October 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6287500
10 October 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6284582
21 September 2017 Annual Inspection · Administrative Inspection · Examination of Repairs · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6271811
3 July 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6195569
26 June 2017 Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6201436
22 June 2017 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6184623
18 June 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6179329
3 June 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6164251
2 May 2017 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6137049
27 March 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6112834
25 March 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6111482
1 March 2017 ACP Periodic Oversight · Administrative Inspection · Periodic Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6096791
27 February 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6096106
24 February 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6094043
29 November 2016 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6049411
18 November 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6043683
24 August 2016 ISM Oversight
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5982604
3 June 2016 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5896305
23 May 2016 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5884581
11 May 2016 ACP COI Oversight · Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5879604
5 May 2016 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5869741
17 February 2016 Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5824549
1 February 2016 Type not recorded
No type recorded · Activities Europe · Activity 5807025
27 January 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5804155

Deficiency record · 42

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 September 2020 Resolved
The fire detection panel in the EDG was indicating a fault on zone 1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 September 2020 Resolved
Port and starboard fuel and crossover piping lagging forward of both MDE’s has oil soaked lagging.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 September 2020 Resolved
A soft patch was discovered on the No.1 SSDG salt water out piping near the plate cooler.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2020 Resolved
The engine case steel vacuum hoses had what appeared to be red hand patches in a few locations on both MDE’s.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2020 Resolved
On the rear of the Stackhouse there was a plug and junction box hanging by its wires. The mount to the bulkhead has wasted through and fell toward the deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 September 2020 Resolved
In the EDG there was missing CO2 activation instructions for the E/R CO2 flooding fixed fire extinguishing system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 September 2020 Resolved
On the deck outside of the emergency diesel generator entrance, a 3X3 patch was discovered covering a hole over the port mess.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 9 December 2020
Resolution: Accepted as condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2020 Resolved
Both steering gear pump suction pipes have what a pears to be silicone caulking on the pipe where it penetrates the tank top plate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 28 September 2020 Resolved
Fire control plan incorrectly displayed the Cargo Tanks of the vessel having installed CO2 protection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 September 2020 Resolved
The #4 and #5 deck fire main stations had leaks in the shutoff valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 28 September 2020 Resolved
Forward life raft is not provided with a ladder.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 September 2020 Resolved
Forward life raft station not equipped with emergency lighting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2020 Resolved
Electrical room outside the galley breaker box had incorrect marking of electrical breakers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2020 Resolved
Electrical room outside the galley breaker box had incorrect size enclosures.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 September 2020 Resolved
Fire main valve outside forward super structure had wasted nuts and bolts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 September 2020 Resolved
There were 3 lifejackets in the ECR labeled with expired battery dates. One of those lifejacket lights did not illuminate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 23 September 2020 Resolved
All quick acting cargo hold hatches were loose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 September 2020 Resolved
The incinerator exhaust in the container is no longer providing support through the overhead penetration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 28 October 2020
Resolution: Accepted as condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 August 2020 Resolved
Sector Jacksonville MI's were informed by the vessel Master that the port main engine would not clutch ahead fully and this therefore affected the vessels fitness for service.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2020
Resolution: Sector Jacksonville MI's witnessed SAT repairs with ABS. Refer to work order 4394858.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 March 2019 Resolved
During periods of high water unless moored to a shore facility or mooring buoys, Captain of the Port New Orleans has determined that all deep draft vessels must have three means to hold position. Vessel's starboard anchor was lost in vicinity of Magnolia Anchorage. Prior to movement, the vessel is to be made capable of a third method of holding position. Transit to Buck Kreighs for replacement of starboard anchor is authorized prior to arrival of assist tugs. SECNOLA MSIB 22FEB2019
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 31 March 2019
Resolved 29 March 2019
Resolution: Rcvd. SAT ABS report of ABS certified anchor installed. CG-835v cleared.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 March 2019 Resolved
The vessel owner/operator must submit a written salvage plan prior to the vessel departing port documenting how the lost anchor will be located and subsequently recovered. The vessel must also submit in writing to the COTP the position (latitude/longitude) and serial number of the lost anchor to aid in future identification.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2019
Resolution: Received email from vessel master with serial number of lost anchor, and GPS coordinates of vessel while anchored. SONAR scans by independent surveyor were unable to locate anchor.
Construction/Loadline › Structures › Superstructure
Issued 1 May 2018 Resolved
Electrical wires running overhead aboce false ceiling passing through fire boudary bulkheads not installed with fire stops. Install proper fire stops and check throughout vessel and install where needed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2018
Resolved 7 June 2018
Resolution: Steel renewal in New Orleans, witnessed by ABS.
Fire Fighting › Self-contained Breathing Apparatus › Quantity
Issued 1 May 2018 Resolved
EEBD missing from Bosun's locker. Approved fire plan shows EEBD location in Bosun locker.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 7 June 2018
Resolution: EEBD in Bosun locker in Emergency cabinet.
Fire Fighting › Means of Escape › Mimic Plans
Issued 1 May 2018 Resolved
STBD side fire plan and crew list holder not labeled "Fire plan", stencil appropriate markings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 7 June 2018
Resolution: "FIRE PLAN" stenciled on tube.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 1 May 2018 Resolved
SOLAS training manuals have not been updated to reflect new owner and vessel name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 7 June 2018
Resolution: Name updated on manuals
Lifesaving › Rescue Boat Equipment › Paddle/Oar
Issued 1 May 2018 Resolved
Oar broken on rescue boat.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 7 June 2018
Resolution: Oar replaced.
Lifesaving › Launching Appliances › Davit
Issued 1 May 2018 Resolved
P/STBD davit structure and stiffners wasted, worn and holed in certain areas. Make appropriate repairs and conduct weight tests as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2018
Resolved 7 June 2018
Resolution: Steel renewal, witnessed by ABS
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 10 October 2017 Resolved
An 835 was issued covering sailing short the First Engineer who quit the vessel on 7 Oct 17. Sailing short request made evening of 7 Oct 17 after not being able to secure a replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2017
Resolved 14 October 2017
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 25 September 2017 Resolved
Waste Oil Incinerator Conex Box is wasted and holed preventing CO2 Fire Suppression System effectiveness. Vessel is restricted from using Waste Oil Incinerator until satisfactory repairs are made.
Action required: 705 - Other - as specified
Due 25 September 2017
Resolved 27 September 2017
Resolution: Holes repaired.
Deck/Cargo › Ballast › Tank
Issued 22 June 2017 Resolved
There is a 14" crack in the deck plate above the #4 ballast tank. Drill stop crack and make temporary repair prior to departing port. Proceed directly to Tampa for offloading and permenant repair. All repairs shall be to the satisfaction of the attending Class and Coast Guard Marine Inspectors that are attending the vsl.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 26 June 2017
Resolution: Attending USCG Marine Inspector and ABS Surveyor witnessed satisfactory final weld test.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 1 March 2017 Resolved
Fire extinguishers, semi-portable and fixed systems annual inspection past due 2/21/17, while vessel was underway. Provide inspection report prior to departure from port to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2017
Resolved 3 March 2017
Resolution: Portable, semi-portable and fixed tested SAT by 3rd party.
Fire Fighting › Fire Hoses › Connections
Issued 1 March 2017 Resolved
Fire hoses at interior fire stations were found not connected to the outlets. Attach all fire hoses to station outlets and ensure connections are maintained to the satisfaction of the attending Marine Inspector.
Due 1 March 2017
Resolved 1 March 2017
Resolution: Fixed on the spot.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 1 March 2017 Resolved
Found hold-back hooks on the Pilot stateroom door and the Navigation bridge door leading to the stair-tower. Permanently remove hold-back hooks to the satisfaction of the attending Marine Inspector.
Due 1 March 2017
Resolved 1 March 2017
Resolution: Fixed on the spot.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 1 July 2016 Resolved
BOSUN stateroom head did not have a properly operating light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2016
Resolution: Replaced bulb
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 1 July 2016 Resolved
AB stateroom head did not have properly operating light or cold water.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2016
Resolution: Replaced light bulb and fixed cold water issue.
Construction/Loadline › Markings › Load Line Mark
Issued 1 July 2016 Resolved
Loadlines were not contrasting colors and were not clearly visible.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2016
Resolution: Loadlines were painted in contrasting color to the hull.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 1 July 2016 Resolved
Emergency Gear Locker #2 had exposed dead end wires hanging from the ceiling.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2016
Resolution: Wires were capped off and stowed in J-Box in overhead.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 1 July 2016 Resolved
Identified a leak in the exhaust of the incinerator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2016
Resolution: Properly welded hole.
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 1 July 2016 Resolved
Missing nonconductive mat IWO the E-gen switchboard.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2016
Resolution: Provided required mat/grating.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 1 July 2016 Resolved
The doors surrounding the Class A fire boundary of the galley space were not closing properly/entirely.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2016
Resolution: The crew adjusted the hinges and closing mechanisms accordingly.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 1 July 2016 Resolved
As per the fire plan posted in the officer’s mess room, the vessel was not provided with appropriate fire blankets IVO the galley. The blankets provided outside the galley space were personal wool thermal blankets.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2016
Resolution: The vessel was provided with approved/appropriate fire blankets and place IAW the ships fire control plan.
Lifesaving › Lifebuoys › Size
Issued 1 July 2016 Resolved
The required 4KG liferings on the bridge wings were replaced with 2.5 KG liferings. Provide 4KG lifebuoys for the bridge wings.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2016
Resolution: The Chief Mate had the rings replaced prior to our departure.

Casualty record · 34

19 June 2002Routine · role: Involved in a Marine Casualty · activity 1736280
8 June 2003Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1821645
14 January 2005Routine · role: Involved in a Marine Casualty · activity 2310796
15 April 2005Routine · role: Involved in a Marine Casualty · activity 2359182
13 May 2005Routine · role: Involved in a Marine Casualty · activity 2367702
5 May 2006Routine · role: Subject to Marine Inspection · activity 2711180
25 February 2007Routine · role: Involved in a Marine Casualty · activity 3078315
16 October 2007Routine · role: Involved in a Marine Casualty · activity 3099602
16 January 2008Routine · role: Involved in a Marine Casualty · activity 3134170
22 January 2008Routine · role: Involved in a Marine Casualty · activity 3142973
25 September 2008Routine · role: Subject to Marine Inspection · activity 3383526
22 September 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3631160
14 June 2010Routine · role: Involved in a Marine Casualty · activity 3775793
16 June 2010Routine · role: Involved in a Marine Casualty · activity 3775822
19 June 2010Routine · role: Involved in a Marine Casualty · activity 3781032
21 June 2010Routine · role: Involved in a Marine Casualty · activity 3788443
7 October 2010Routine · role: Involved in a Marine Casualty · activity 3874774
11 March 2011Routine · role: Involved in a Marine Casualty · activity 3965525
14 March 2011Routine · role: Involved in a Marine Casualty · activity 3965257
9 November 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4186455
6 June 2012Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4335932
20 January 2013Routine · role: Involved in a Marine Casualty · activity 4540135
2 February 2013Routine · role: Involved in a Marine Casualty · activity 4540011
21 July 2013Routine · role: Acknowledged Pollution Source · activity 4663041
8 August 2013Routine · role: Involved in a Marine Casualty · activity 4680127
5 September 2013Routine · role: Involved in a Marine Casualty · activity 4707584
13 January 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4787712
29 August 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4972257
27 February 2015Routine · role: Involved in a Marine Casualty · activity 5077673
1 February 2016Routine · role: Involved in a Marine Casualty · activity 5807025
3 June 2016Routine · role: Acknowledged Pollution Source · activity 5896305
27 November 2018Routine · role: Transiting Vicinity of Primary Subject · activity 6593075
21 February 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6632602
21 August 2020Routine · role: Involved in a Marine Casualty · activity 7038927
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

CYNTHIA FAGAN (2002–2005), MARY ANN HUDSON (2006–2014). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.