13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 November 2025
Resolved
Gears, couplings, flywheels, and all rotating machinery capable of injuring personnel must be provided with adequate covers or guards. Multiple guards on machinery damaged/corroded; STBD FWD winch cable drum, aux saltwater pump coupling, oil circulating pump, ect. 46 CFR 58.01-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2025
Resolved 2 December 2025
Resolution: Reviewed pictures attesting to repairs; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 November 2024
Resolved
Each individual bilge suction shall be fitted with a suitable bilge strainer having an open area of not less than 3 times that of the suction pipe. All bilge suctions had strainers removed. Replace and provide documentation attesting to installation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 November 2024
Resolution: Received documentation that strainers were installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 December 2023
Resolved
For industrial vessels of 300 gross tons and over but less than 4,000 gross tons, contracted for prior to July 1, 1968, which carry in excess of 12 industrial personnel, existing structure arrangements and materials previously approved will be considered satisfactory so long as they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. MI found structural wastage, openings, and holes along the entire machinery space boundary, a space protected by CO2 fixed extinguishing system.
46 CFR 92.07-90(b), 46 CFR 95.15-35(b)(c), Action Code 705: Until current contracted work is completed in Southwest Pass.
Action required: 705 - Other - as specified
Due 1 February 2024
Resolved 16 April 2024
Resolution: MI witnessed multiple areas with renewed metal correcting the wastage and holes in the machinery space. all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 5 December 2023
Resolved
The inspection shall be such as to insure that the vessel, as regards the structure is in satisfactory condition and fit for the service for which it is intended. During the general walk-through MI discovered multiple holes in the superstructure of the vessel. Concerning holes and wastage was found on bulkhead to the machinery space, fuel vents, decking, ladder wells and stanchions supporting the 03 Portable Accommodation Module. Complete repairs to the satisfaction of the attending marine inspector at the next dry-dock, anticipated in OCT 2024.
46 CFR 91.25-10, Action Code: 705
Action required: 705 - Other - as specified
Due 5 December 2023
Resolved 16 April 2024
Resolution: MI conducted complete walk around vessel, deck, house, and PAMS. All wasted metal had been renewed.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 5 December 2023
Resolved
General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads. When reviewing the fire control plan. Plan did not have markings for fire-resisting bulkheads. Revise plan to the satisfaction of the attending Marine Inspector at the next dry-dock, anticipated in OCT 2024.
46 CFR 97.36-1(a), Action Code: 705, Complete at dry-dock
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 5 December 2023
Resolved 25 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 November 2022
Resolved
Each power bilge pump must have the capacity to develop a suction velocity of no less than 400' per minute. Vessel was not able to draw suction from bilge pump in engineer plant.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2022
Resolved 16 December 2022
Resolution: Vessel was able to draw suction from bilge pump in engineer plant.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 15 November 2022
Resolved
Fire pumps may be used for other purposes provided at least one of the required pumps is kept available for use on the fire system at all times. The #2 fire pump has excessive water leaking from the packing. Repair to the satisfaction of attending MI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2022
Resolved 16 December 2022
Resolution: Repair to #2 fire pump packing completed.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 15 November 2022
Resolved
Fire Main - All piping, valves and fittings shall meet subchapter F. Vessel had at least 02 soft patches applied to it. Renew piping to the satisfaction of the attending MI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 December 2022
Resolved 16 December 2022
Resolution: Fire Main piping has been renewed.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 15 November 2022
Resolved
In spaces where the general emergency alarm signal cannot be heard over the background noise, there must be a red flashing light or rotating beacon. Bilge alarm and GE alarm light or beacon in generatior room are not working. Repair to the satisfaction of attending MI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2022
Resolved 16 December 2022
Resolution: Bilge & GE alarms tested satisfactory.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 15 November 2022
Resolved
All generator alarm bells shall be identified by red lettering at least 1/2" "GENERAL ALARM - WHEN BELL RINGS GO TO YOUR STATION." The beacon and bell in the gen room were not labeled. Replace to the satisfaction of attending MI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2022
Resolved 16 December 2022
Resolution: Beacon and bell in gen room have been labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 November 2022
Resolved
Pressure vessels that are required to be stamped must have the following: manufacture's name and serial #, Coast Guard #, Coast Guard symbol, MAWP, Class, min design temp & water capacity in liters. The #2 air receiver in the gen room has a wasted data plate. Renew or replace to the satisfaction of attending MI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2022
Resolved 16 December 2022
Resolution: The #2 air receiver has been replaced.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 November 2022
Resolved
Class 1 doors are permitted within crew and working spaces wherever located if in the judgement of the OCMI the door is located where it will be closed at all times except when in use. Class 1 WTD located at frame 71 between the gen room and pump room cannot be closed. Repair to the satisfaction of the the attending MI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2022
Resolved 16 December 2022
Resolution: Class 1 WTD has been repaired and is able to close.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 November 2022
Resolved
Electrical equipment must be arranged as far as practicable to prevent mechanical damage to the equipment from dust, oil, steam or dripping liquids. The spring bearing cooler OVBD at frame 57 STBD side is leaking on top of a heater controller and another fuse/breaker panel or junction box. Repair to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2022
Resolved 16 December 2022
Resolution: Spring bearing cooler OVBD at frame 57 STBD side has been repaired and not leaking.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 November 2022
Resolved
Complete but simple instructions for the operation of the system must be located in a conspicuous place at or near all pull boxes, stop valve controls. Paint locker fire extinguishing instructions are weathered/faded; clean or replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2022
Resolved 28 December 2022
Resolution: Fire extinguishing instructions have been renewed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 November 2022
Resolved
Within the accommodation and service area the following conditions shall apply:... Portable accommodation module (PAM) No. 1 has 02 improper electrical cable way penetrations through class A boundry.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2022
Resolved 28 December 2022
Resolution: PAM No. 1 electrical cable way penetrations have been repaired.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 15 November 2022
Resolved
Barges with sleeping accommodations for more than six persons...shall have permanently exhibited for the guidance of the officer in charge of the vessel... Fire control plan has not been updated to reflect current safety controls (ie. smoke detection, general alarm, and ESD, etc.).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2022
Resolved 19 December 2022
Resolution: Fire control updated to reflect safety controls.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 31 May 2022
Resolved
No repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met.
Vessel reported they found a 2" diameter hole in the starboard store room bilge (FR 26) near the forward transverse bulkhead. Vessel is authorized 01 time transit to emergency dry dock for permanent repairs. 46 CFR 2.01-15(a)
Action required: 60 - Rectify deficiencies prior to movement
Due 31 May 2022
Resolved 17 June 2022
Resolution: Vessel made repairs with an insert to the satisfaction of the Coast Guard.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 8 September 2021
Resolved
The general alarm system shall consist of electric vibrating bells and in certain cases flashing red lights located throughout passenger and crew's quarters, machinery spaces, and so long as to warn all occupants in an emergency.Vessels general alarm did not sound in Chief Engineer and Captains stateroom when exterior doors were in the closed position.
Old subchapter "J" 46 CFR 113.25-5(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2021
Resolution: Cleared by Sector NOLA MI's.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 September 2021
Resolved
Vessels on all routes 1600 GT's and over are required to have staorage batteries or diesel or gas turbine generator automatically or manual operated for a 12 hour operational period. Vessel crew was unable to start emergency generator for operational testing and to test alarms and shutdowns.
OLd "J" 46 CFR 112.05-5(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2021
Resolution: Cleared by Sector NOLA MI's.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 September 2021
Resolved
At each inspection for certification and at such other times as considered necessary the inspector shall determine that all fire-extinguishing equipment is in suitable condition and may require such test as are considered necessary to determine the condition of equipment. #3-5 fire hydrants had excessive leaking at the valve.
Old "I" 46 CFR 91.25-20(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2021
Resolution: Tested hydrants under system pressure, all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 September 2021
Resolved
Suitable guards shall be installed in way of exposed in dangerous places such as gears and machinery. Vessels dredge pump gears were exposed in machinery space posing a hazard to personnel.
Old " I" 46 CFR 92-25-15(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2021
Resolution: Cleared by Sector NOLA MI's.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 September 2021
Resolved
At each inspection for certification and at such other times as considered necessary the inspector shall determine that all fire-extinguishing equipment is in suitable condition and may require such test as are considered necessary to determine the condition of equipment. Vessels number 2 Fire/Service pump had excessive leaking at packing gland and leaking a large amount of water in bilge.
Old "I" 46 CFR 91.25-20(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2021
Resolution: Packing renewed. Conducted operational test of fire pump.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 September 2021
Resolved
When a manually started emergency lighting and power system is installed, the circuits listed in 46CFR 112.15-5,(embarkation station, passenger quarters, crew quarters, public spaces, machinery spaces shall be arranged so that they may be energized from the emergency source of supply.
Vessel had emergency lighting throughout vessel that was inoperable and no lighting in machinery spaces.
Old "I" 46 CFR 112.15-15(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2021
Resolution: Installed more lighting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 September 2021
Resolved
No repairs or alterations affecting the safety of the vessel with regard to hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Vessel had an unapproved portable rental generator to replace missing required main generator. Vessel is required to submit plans for approval to use portable generator or replace original main generator.
Old "I"
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2021
Resolved 25 April 2022
Resolution: Inspected instillation of new ABS approve generator. Def check Activity #7435988
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2021
Resolved
Installation of all systems of electrical engineering or interior communication nature, together with the details of design, construction and installation shall be in accordance with the requirements of subchapter "J". Vessel had junction box fwd upper machinery space that had wires pulled out of box and wire runs above emergency fire pump are being chaffed due to broken stuffing tube.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2021
Resolution: Cleared by Sector NOLA MI's.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 8 September 2021
Resolved
No repairs or alterations affecting the safety of the vessel with regard to hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Vessel had a soft patch on pipe coming from the main seachest to vessels main generator and all other onboard engines.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2021
Resolution: Section of piping was renewed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 8 September 2021
Resolved
46 CFR 56.70 (c)
Where fuel tanks are installed below weather deck, arrangements shall be provided for operating all shutoff valves at the tank outside the compartment where its located. Remote fuel shutoff valves from day tanks inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2021
Resolution: Cleared by Sector NOLA MI's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 September 2021
Resolved
Each vessel must carry lifebuoys approved under approval series 160.150.
Lifebuoy lines were deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2021
Resolution: Cleared by Sector NOLA MI's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 September 2021
Resolved
At least one-half the total number of lifebuoys on the vessel must each be fitted with a self-igniting light approved under approval series 161.010. Lifebuoy lights did not work and were replaced with wrong battery.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2021
Resolution: Cleared by Sector NOLA MI's.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 September 2021
Resolved
Exhaust pipe installations must conform with requirements of ABYC P-1 and part 1 section 23 of NFPA 302. Exhaust lagging on ship service diesel generator was missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 September 2021
Resolved
There shall be at least two means of escape from all general areas accessible to the passengers if carried or where the crew may be quartered or employed. The emergency escape aft starboard side machinery space was seized and unable to be opened.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2021
Resolution: Cleared by Sector NOLA MI's.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 March 2021
Resolved
Fire hydrants shall be of sufficient number and located that any part of the vessel accessible to persons on board while the vessel is being navigated may be reached with at least 2 streams of water from separate outlets, one of which shall be from a single length of hose.
A single length of 50' hose could not reach the portable accommodation modules.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2021
Resolution: Installed 4 hydrants to reach each PAM.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 16 March 2021
Resolved
The use of low melting point materials must not be used in vital systems unless approved by MSC. Vessel has plastic piping used in the fire main system.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2021
Resolution: Removed PVC from firemain. Piped toilet water to freshwater system.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 16 March 2021
Resolved
No repairs or alterations affecting the safety of the vessel with regard to hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Vessels fire main supplies water to the accommodation modules. Produce approved fire main drawings showing this modification.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 15 September 2021
Resolution: Updated fire plan with new hydrants.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 2 December 2020
Resolved
All general alarm bells shall be identified by red lettering at least 1/2 inch high: "GENERAL ALARM-WHEN BELL RINGS GO TO YOUR STATION" General Alarm in vessel's galley does not have required markings.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 7 December 2020
Resolution: Vessel provided appropriate markings to the satisfaction of the reviewing Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 December 2020
Resolved
Alcohol testing devices need not be carried on board each vessel if obtaining the devices and conducting the required alcohol tests can be accomplished within 2 hours from the time of occurrence of the SMI. Vessel's on board alcohol testing strips expired in 2017. Vessel was unable to provide proof of available test kits within two hours.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 7 December 2020
Resolution: Vessel provided alcohol testing devices as required.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 December 2020
Resolved
a) For all vessels of 4,000 gross tons and over contracted for prior to January 1, 1962, existing structure arrangements and materials previously approved will be considered satisfactory so long as they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. Minor repairs and alterations may be made to the same standard as the original construction. Major alterations and conversions shall be in compliance with the provisions of this subpart to the satisfaction of the Officer in Charge, Marine Inspection. Fire doors in the machinery space leading into the switch board do not latch lose, have missing mechanical latches and doors are rusted through. Fire boundary doors throughout vessel were also found not to latch properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 31 July 2021
Resolution: New approved fire doors were installed and tested, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 December 2020
Resolved
Nameplates: Each tray shall be provided with a durable nameplate securely attached, bearing the manufacturer’s name or trade mark and type designation, the ampere-hour rating at a specific rate of discharge, and the specific gravity of the electrolyte. Date molded on the tray case will be acceptable in lieu of a nameplate.
No information on battery trays in the switchboard room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 7 December 2020
Resolution: Vessel provided nameplates as required, to the satisfaction of the reviewing Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 December 2020
Resolved
Ventilation: all rooms, lockers, and boxes for storage batteries should be arranged or ventilated to avoid accumulation of flammable gas.
Poor ventilation in the stbd side switchboard room where the batteries and charger is located.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 7 December 2020
Resolution: Vessel improved ventilation to the satisfaction of the reviewing Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 April 2019
Resolved
All marine engineering details such as piping, valves, fittings, boilers, pressure vessels, etc., and their appurtenances installed on the vessel, shall be designed, constructed, and installed in accordance with the provisions of subchapter F (Marine Engineering) of this chapter. Vessel's Firemain piping had hole in it.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2019
Resolution: Repaired firemain piping and hydrotested to 1.5 PSI above MAWP. Test SAT!
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 April 2019
Resolved
All electrical engineering details and installations shall be designed and installed in accordance with subchapter J (Electrical Engineering) of this chapter. Extention Cord was wired in electrical distribution panel.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2019
Resolution: Extention cord was removed and approved marine grade cable and recepticle was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 April 2019
Resolved
Each generator prime mover must have an overspeed device that is independent of the normal operating governor and adjusted so that the speed cannot exceed the maximum rated speed by more than 15 percent. MI was unable to test overspeed device due to failure in overspeed device.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2019
Resolution: Tested all required overspeeds in accordance with regulatory requirements.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 April 2019
Resolved
No repairs or alterations affecting the safety of the
vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Vessel conducted repairs to CG approved Type II MSD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2019
Resolution: Repairs were made by an approved facility. Test SAT
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 November 2018
Resolved
A survey, either general, or partial according to the circumstances shall be made every time an accident occurs. Following report of damage to fore-peak area, submit temporary repair proposal to MI. iaw 46CFR91.30-1(a)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 28 November 2018
Resolution: Temporary repair conducted with welded box and cement patch to satisfaction of attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 November 2018
Resolved
The survey shall be such to insure that the necessary repairs have been effectively made. Provide repair proposal and complete permanent repairs prior to credit drydock in 18Aug19. iaw 46CFR91.30-1(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 19 July 2019
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 10 October 2017
Resolved
Properly connect the hydrostatic release units to the inflatable liferafts.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 October 2017
Resolved
Replace all expired floatlight batteries
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 17 October 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 October 2017
Resolved
Make operable port running light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 10 October 2017
Communications › Radio Communications › EPIRB
Issued 10 October 2017
Resolved
Properly mark EPIRB hydrostratic release unit with next service date.
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 12 October 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 10 October 2017
Resolved
Provide and install CO2 system instructions and diagram.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 26 October 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 October 2017
Resolved
Provide test report for all bilge CO2 system bilge nozzles.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2017
Documentation › Markings/Placards › Warning Signs
Issued 10 October 2017
Resolved
Provide CO2 warning placard throughout machinery spaces protected by CO2.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2017
Documentation › Markings/Placards › Oil Discharge Placard
Issued 10 October 2017
Resolved
Provide updated MARPOL placards in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 16 October 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 October 2017
Resolved
Properly terminate dead-end wiring in junction box or remove.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 24 October 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 October 2017
Resolved
Remove permanent extension cords and power strips throughout vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 10 October 2017
Engineering › Sea-water System (primary cooling) › Pump
Issued 10 October 2017
Resolved
Make repairs to auxiliary generator cooling pump leaking shaft seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 10 November 2017
Engineering › Fuel Oil Service System › Hose
Issued 10 October 2017
Resolved
The auxiliary generator supply fuel hose may only be 30" in length. Provide and install hard pipe for section exceeding 30".
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 20 October 2017
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 19 January 2016
Resolved
Submit plan and complete permanent repairs on fuel tank #8 prior to placing fuel in and placing tank back into service.
Action required: 705 - Other - as specified
Resolved 8 September 2016