Records from 1994 to 2024. Most recent: inspection, 13 August 2024.
Documentation record
Registered dimensions (L × B × D)51.1 ft × 20.0 ft × 7.1 ft
Registered tonnagegross 70 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLOUIS G ORTIS BOAT CO · KROTZ SPRINGS, LA, UNITED STATES · built 1973
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT ARTHUR, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it70 - Regulatory (Subpart C or D), Gross Ton
43 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 28
13 August 2024
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7980436
5 January 2023
TPO Audit · Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7616988
29 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7440564
23 August 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7294430
15 August 2019
COI Inspection · Examination of Repairs · Initial Certification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6784400
23 July 2019
Initial Certification · COI Inspection · MTSA Verification · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6759778
22 July 2019
TPO Audit
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6758882
31 March 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6653451
24 December 2018
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6608052
15 May 2014
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4859798
21 January 2014
Industry Initiated Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4787315
3 March 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4263744
9 April 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3713019
11 February 2010
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3678317
13 April 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2624151
12 April 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2332348
4 March 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2332002
4 October 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2213257
2 March 2004
Security Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2016730
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979074
24 March 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1767458
5 January 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 273531
8 May 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 416430
1 October 1997
MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1120882
14 January 1997
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 81474
29 May 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 391771
22 March 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 158407
2 August 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 369132
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2019
Resolved
Electrical systems must minimize system failures, fire and shock hazards. Electrical equipment must be marked. Individual circuit breakers must be labeled. Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Electrical equipment and electric wires must be suitably protected from wet environments. Electrical components posing an electrical hazard must be in an enclosure. Electrical components passing through watertight bulkheads must be installed so that the bulkhead remains watertight. Connections of flex cable plugs must be designed to prevent unintended separation. There were numerous wires and cables in the bridge (below equipment panel) and in the engine room that were spliced, dead-end and exposed and not in a junction box, posing a fire and shock hazard. Wiring was loose and not suitably installed. Electrical connections were not labeled or marked. Vessel is required to put dead end/spliced cables in junction boxes or remove them. Vessel is required to ensure that cables and wiring are suitably affixed so as not to come loose, to include elimination of loose extension cords.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2019
Resolved 16 August 2019
Resolution: Exposed wires removed or placed within an enclosure
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2019
Resolved
Vessel is required to to have circuitbreakers and switch boards labeled with a description of the loads they serve. Circuit breakers were not properly labeled. Marker used to list out potential loads did not properly identify which circuit breaker went to which load. Vessel required to properly mark all circuit breakers
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2019
Resolved 16 August 2019
Resolution: circuit breakers were labeled
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 1 August 2019
Resolved
Piping for flammable or combustible liquid, seawater cooling, or firefighting systems must be fitted with isolation valves that are clearly marked by labeling or color coding that enables the crew to identify its function. Any valve that penetrates the full below the waterline must be clearly marked by labeling or color coding that enables the crew to identify its function. Piping systems and valves throughout engine room were not color coded or labeled as required. Vessel is required to label and color code all valves and piping systems for flammable or combustible liquid, seawater cooling, firefighting, as well as valves penetrating the hull below the waterline.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2019
Resolved 16 August 2019
Resolution: All valves were painted/color coded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 August 2019
Resolved
Each lifeline on a lifebuoy must be of a dark color if synthetic or of a type to be resistant to deterioration from ultraviolet light. While conducting a deck walk, the Marine Inspector identified the lifeline on the port side ring buoy was significantly deteriorated and needs to be replaced. Vessel is to replace lifeline on port
side ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2019
Resolved 1 August 2019
Resolution: Line replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 1 August 2019
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. Air conditioning units penetrating the house did not have covers and one unit was missing louvers. Vessel is required to provide closure devices to protect openings where air conditioning units are mounted from excessive water ingress.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2019
Resolved 16 August 2019
Resolution: Determined by OCMI as weathertight
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 August 2019
Resolved
Each towing vessel must comply with 46 CFR part 4 for reporting marine casualties and retaining voyage records. Vessel unable to provide a log for known date of recent reportable marine casualty. Vessel is required to maintain voyage records related to marine casualties and to place onboard missing documentation from recent marine casualty.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2019
Resolved 16 August 2019
Resolution: Vessel agreed to maintain all necessary records in future.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 August 2019
Resolved
All equipment must be used in accordance with manufacturer's recommended practice. Equipment not in working order must be removed. The vessel must be kept in a sanitary condition. Crew accommodation and work space must provide for safe operation of vessel and protection and accommodation of crew. There were numerous tripping hazards throughout vessel incl garbage & broken materials strewn about deck, incl out of service tools and broken chair. Fan hanging by a cord in engine room and not in accordance with manufacturers rec practice. Vessel to remove garbage, stow out of use equipment and remove or properly mount fan. See also 46 CFR 144.700
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2019
Resolved 1 August 2019
Resolution: Vessel removed garbage from deck and took down fan in engine room hanging from cord
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2019
Resolved
Electrical equipment must be protected from wet and corrosive environments. Cord for electrical in engine room was located in water (in bottom of bilge - while plugged in) creating electrical hazard. Vessel to remove any electrical cords in bige.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2019
Resolution: Vessel removed cord from bilge in inspectors presence
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2019
Resolved
Electrical equipment and cables must be suitably protected from wet and corrosive environments. Closure devices must be provided for hull penetrations/deckhouse penetrations. There were drill holes in area where wiring in pilot house was located resulting in water ingress and mold around electrical cables. Pilot house electrical cables must be made water tight. See also 46 CFR 144.320
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2019
Resolved 16 August 2019
Resolution: Drill holes were filled to prevent water ingress
Unknown
Issued 29 May 1996
Resolved
VESSEL DID NOT HAVE THE OFFICIAL NUMBERS PERMANETLY MARKED ONBOARD.
Condition: Unknown
Due 28 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 29 May 1996
Resolved
A COPY OF THE INLAND NAVIGATION RULES WERE NOT ON BOARD THE VESSEL.
Condition: Unknown
Due 28 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 29 May 1996
Resolved
VESSEL DID NOT HAVE THE PROPER SIZE BELL INSTALLED.
Condition: Unknown
Due 28 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past