Records from 1992 to 2025. Most recent: inspection, 4 December 2025.
Documentation record
Registered dimensions (L × B × D)93.2 ft × 30.0 ft × 9.7 ft
Registered tonnagegross 321 / net 213
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUPERIOR BOAT WORKS INC · GREENVILLE, MS, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLAKE PROVIDENCE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 December 2025 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it213 - Regulatory (Subpart C or D), Net Ton
321 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 30
4 December 2025
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8312774
28 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8041043
28 November 2024
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8044376
22 February 2024
In-Service Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7869456
2 November 2022
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7588356
25 September 2022
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7570600
16 November 2020
Initial Certification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7104582
1 October 2020
TPO Audit
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7076216
10 April 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6659964
31 March 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6653451
4 May 2018
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6784436
21 October 2017
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6294855
15 April 2016
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5854865
18 June 2014
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4893264
15 May 2014
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4860030
18 June 2013
Industry Initiated Exam · DAPI Audit · Administration · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4624827
26 May 2005
Uninspected Other
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2385266
17 June 2002
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1651462
7 December 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1473836
9 October 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 177659
8 July 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 205826
8 July 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 758501
21 May 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 60044
21 May 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 116813
12 April 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 656413
22 February 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 375634
1 April 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 357324
9 March 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 356868
20 March 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 656408
16 March 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 121523
Engineering › Freshwater System (cylinder head cooling) › Storage Tank
Issued 26 May 2005
Resolved
Expansion over-filled by crew antifreeze leaked onto deck.
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 27 May 2005
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 26 May 2005
Resolved
Marine Sanitation Device was operating but the access cover was rusted out and needed to be replaced/repaired. Also the manufacture plate was missing on the MSD.
Action required: 705 - Other - as specified
Due 2 June 2005
Resolved 2 June 2005
Fire Fighting › Fire Pumps › Location
Issued 26 May 2005
Resolved
Vessel had fire pump in engine room, but did not have a remote start located outside the engine room. We had the company place a portable fire pump onboard. Company will rewire main fire pump to start from a remote location.
Action required: 705 - Other - as specified
Due 9 June 2005
Resolved 9 June 2005
Fire Fighting › Semiportable CO2 Fire Extinguishers › Marine Type Label
Issued 26 May 2005
Resolved
The B-V semi-portable fire-extinguishing system is not properly marked as Marine Type approved. Company directed to request an extension to the new requirements. The company bought a system that is not Marine Type. Company will replace existing B-V with an approved system prior to the 17 June 2005.
Action required: 705 - Other - as specified
Due 17 June 2005
Resolved 17 June 2005
Accommodation/Occupational Safety
Issued 22 February 1995
Resolved
NO MARPOL PLACARD ON M/V SENATOR SAM.
Condition: Unknown
Due 22 February 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 22 February 1995
Resolved
NO OIL TRANSFER PROCEDURES FOR M/V SENATOR SAM.
Condition: Unknown
Due 22 February 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 22 February 1995
Resolved
NO NAME MARKED ON EITHER BOW.
Condition: Unknown
Due 1 March 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 22 February 1995
Resolved
NO COD WAS ON BOARD M/V SENATOR SAM AT TIME OF BOARDING.
Condition: Unknown
Due 22 February 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 22 February 1995
Resolved
M/V SENATOR SAM HAS NO COFR.
Condition: Unknown
Due 22 February 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 22 February 1995
Resolved
NO REQUIRED INFO IN RECORDS. NO DESIGNATED PIC LIST FOR TRANSFER OPERATIONS.
Condition: Unknown
Due 22 February 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 22 February 1995
Resolved
DOI NOT ON BOARD.
Condition: Unknown
Due 22 February 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 22 February 1995
Resolved
O5 FIRE EXT. DID NOT HAVE CG OR UL APPROVAL NUMBERS.
Condition: Unknown
Due 22 March 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 22 February 1995
Resolved
NO METAL OR MYLAR TAGS ON EXTINGUISHERS.
Condition: Unknown
Due 22 March 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 9 March 1993
Resolved
NO MARPOL PLACARD ON BOARD VESSEL.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Documentation
Issued 9 March 1993
Resolved
DOCUMENTATION CERTIFICATE NOT ON BOARD. (ORIGINAL IS AT OFFICE)
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993