Records from 2016 to 2026. Most recent: inspection, 1 July 2026.
Inspection history · 39
1 July 2026
Damage Survey · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8421641
6 February 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8308305
14 February 2025
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8079707
12 February 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8078869
25 April 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7901512
5 January 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7845773
15 November 2023
Internal Structural Exam · In-Service Inspection · Administrative Inspection · Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7825505
13 August 2023
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7791333
27 March 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7657722
23 January 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7625664
18 March 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7414060
17 December 2021
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7369632
9 December 2021
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7365455
8 November 2021
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7397313
29 September 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7323389
16 July 2021
Damage Survey · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7256302
7 June 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7218578
26 April 2021
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7182883
18 February 2020
COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6910585
14 November 2019
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6855709
17 October 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6836611
4 October 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6829601
1 October 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6825840
25 September 2019
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6821021
8 August 2019
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6801042
30 May 2019
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6699451
30 April 2019
In-Service Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6673495
29 April 2019
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6683039
3 December 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6588947
28 July 2018
Special
Type not classified · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6496893
5 June 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6434888
12 April 2018
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6390298
9 July 2017
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6202938
13 June 2017
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6174339
30 March 2017
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6118239
4 November 2016
Examination of Repairs · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6041266
30 August 2016
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5988563
4 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5849154
4 April 2016
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5861761
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 July 2026
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Extensive damage to bow and gangway. Provide a Naval Architect or P.E. letter attesting to the vessels ability to transit to the location of repair. Once at repair location, work with the local Coast Guard unit and conduct survey and effect repairs as needed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2026
Resolution: Non-destructive testing of bow repair was tested and found satisfactory. Gangway repairs visually inspected and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 23 March 2026
Resolved
Each launching appliance must be in good working order and ready for immediate use.
Rescue boat winch cable observed frayed and unserviceable. Vsl will replace the cable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2026
Resolution: Vsl replaced davit cable.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 March 2026
Resolved
Penetrations in A-Class fire control boundaries for electrical cables must be constructed to prevent the passage of flame and smoke for one hour.
Blue cables outside of male crew berthing area observed missing insulation through 02 fire boundaries. Vsl will reinstall insulation through ladderwell boundary and
cover gaps with fire proof caulking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2026
Resolved 24 March 2026
Resolution: Reinstalled insulation and fire proof caulking.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 March 2026
Resolved
At least one ring buoy must be fitted with a floating waterlight approved IAW 161.010.
Retroflective tape on waterlights observed deteriorated. Replace tape or procure replacement lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2026
Resolved 24 March 2026
Resolution: Replaced 02 waterlights.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 March 2026
Resolved
Each terminal part of a conductor must be made within an enclosure or have a pressure type connector or a solder lug.
Cables in engine room overhead near loudhailers observed taped with electrical tape. Cap terminal cable ends in accordance with CFR requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2026
Resolved 23 March 2026
Resolution: Capped terminal cable ends.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 March 2026
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces.
02 emergency lights observed not working.
Vsl replaced light batteries.
Action required: 10 - Deficiency Rectified
Resolved 23 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 February 2026
Resolved
Adult life jackets with appropriate approval series
number must be provided for each person onboard.
Observed vsl equipped with 206 adult lifejackets. 08
lifejackets observed missing clips.
Vsl procured 06 additional lifejackets and 08 clips to
meet 210 onboard.
Action required: 10 - Deficiency Rectified
Resolved 23 March 2026
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 14 February 2025
Resolved
46CFR 122.520 and 524
IAW the above CFR Cites, Fire and Boat Drills must be conducted and witnessed by the Coast Guard prior to getting underway with passengers. Call to schedule the inspection at [phone withheld].
Due 10 April 2025
Resolved 25 March 2025
Resolution: All required drills held satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 April 2024
Resolved
Emergency lighting must automatically actuate upon failure of main lighting system. Two emergency lights in the aft machinery space, two emergency lights in the male crew berthing, and an emergency light in the Sky Lounge (common area) were not actuating. Repair emergency lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2024
Resolved 7 May 2024
Resolution: Repaired. Report in docs.
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 26 April 2024
Resolved
A door in a main vertical zone bulkhead must be self closing. Self-closing fire doors on 5th deck (aft), 4th deck (aft), and 2nd deck (forward) did not fully close and latch. Repair doors so that they fully close and latch properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2024
Resolved 7 May 2024
Resolution: Repaired. Report in docs.
01 - Certificates & Documentation › 013 - Documents › Shipboard marine pollution emergency plan for NLS
Issued 29 September 2021
Resolved
Nontank vessels subject to this subpart may not operate upon the navigable waters of the United States unless in compliance with a vessel response plan (VRP) approved under § 155.5065. Vessel was observed operating in the MSU Pittsburgh COTP zone without an approved VRP. Provide updated VRP as required.
Before getting underway, provide MSU Pittsburgh COTP with requirements found in 33 CFR 155.5025.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 December 2021
Resolution: MSU Pittsburgh added to VRP.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 February 2020
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules (incorporated by reference, see 46 CFR 58.03-1), except as otherwise provided by this subchapter. During operational testing of Z-Drive propulsion, discovered 2 sheared, and multiple loose mounting studs on Center installation resulting in slight shifting and movement upon clutch control. Loose hardware was corrected, but broken studs cannot be serviced with vessel in water and unit installed. At next dry dock, replace broken studs IAW manufacturer recommendations.
46 CFR 58.05-1(a)
46 CFR 119.220(a)
Action required: 705 - Other - as specified
Resolved 19 March 2020
Resolution: Recieved photos and email from company rep. Studs drilled out and replaced with Grade-8 welded bolts of in-kind size and dimension.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 October 2019
Resolved
Crew training record required to be made available for review upon request. Crew training for emergency instruction placard and station bill duties not available. Make records available. 46 CFR 122.420
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2019
Resolved 17 October 2019
Resolution: Captain provided recent crew training records for duties and responsibilities during emergencies.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 October 2019
Resolved
Monthly abandon ship drill required to be logged. No abandon ship drill logged between 6-1-19 and 10-2-19. Properly log abandon ship drills.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2019
Resolved 17 October 2019
Resolution: Captain provided records of recent drills.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 4 October 2019
Resolved
Three surge protectors daisy chained into a single outlet was found in crew members stateroom presented a risk of fire hazard and not good marine practice. 46CFR115.800/46CFR116.405
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 4 October 2019
Resolved 4 October 2019
Resolution: The Captain of the vessel removed the three surge protectors from the stateroom prior to the departure of the CG Marine Inspector. The deficiency was cleared by the attending CG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 October 2019
Resolved
During spot check of emergency "E" lighting fixtures found multiple lights inoperable. Prove proper operation of all "E" lighting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2019
Resolved 17 October 2019
Resolution: Walked throughout vessel and verified proper operation of each emergency light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 October 2019
Resolved
Distribution panel #14 in lower crew aft quarters was missing breaker blank.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2019
Resolved 17 October 2019
Resolution: Verified all slots in the distribution panel were filled.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 September 2019
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] plans to the USCG Marine Safety Center for the addition of a high water alarm point in the space forward of the bow thruster tunnel prior to vessel's scheduled drydock exam.
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 14 November 2019
Resolution: Tested newly installed high water alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 May 2019
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practicable conditions. Furthermore, each vessel must be provided with a visual and audible alarm to indicate a high water level in a space subject to flooding. Proper drainage to bilge suction is inhibited by permanent concrete blockages and bilge high level alarm is positioned next to bilge suction, so it is unable to sense high water level in forward part of space. Due to necessity of vessel being in drydock to make permanent repairs, temporary measures must be established to ensure forward portion of space is monitored for flooding. Temporary measures must also be established to ensure proper bilge drainage. Company
must submit plan to OCMI detailing plans and timelines to make permanent repairs.
Action required: 705 - Other - as specified
Due 30 May 2019
Resolved 14 November 2019
Resolution: Vessel installed and verified operation of new high water alarm.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 May 2019
Resolved
All escape hatches and other emergency exits must be marked with "EMERGENCY EXIT, KEEP CLEAR." Exits from the forward machinery space and paddle wheel lounge space were not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2019
Resolved 13 June 2019
Resolution: Exits were marked properly.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 30 May 2019
Resolved
The manufacturer's instructions for onboard maintenance of rescue boats and launching appliances must be onboard or vessel must have planned maintenance program for rescue boat and launching appliances. Inspection and maintenance of equipment shall be logged or otherwise documented for review by Coast Guard. Vessel did not have maintenance instructions, proof of program, or maintenance logs available during inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 18 June 2019
Resolution: Vessel has a maintenance plan and logs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2019
Resolved
The name of the vessel must be marked or painted in clearly legible letters on the ring life buoys. Re-mark life ring buoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 13 June 2019
Resolution: Ring Life buoys properly marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 April 2019
Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil shall provide transfer procedures. Procedures must be posted or available at a place where they can be easily seen and used when engaged in transfer operations. Vessel did not have a copy of fuel transfer procedures onboard. Vessel must provide an onboard copy of Fuel Transfer Procedures prior to next bunkering operation.
Action required: 703 - Prior to bunkering operations
Resolved 2 May 2019
Resolution: Fuel Transfer Procedures have been placed onboard vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 April 2019
Resolved
The operator of a vessel that is required to have fuel transfer procedures shall maintain them current. The OCMI may require the vessel operator to amend those procedures if they do not meet requirements. Fueling procedures currently used in practice onboard vessel are not in accordance with the vessel's written fuel transfer procedures. Amend written procedures to align with actual procedures used onboard. Proper clearance of this deficiency requires an onboard verification by USCG Marine Inspector, ensuring amended procedures are sufficient and in practice aboard vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 30 May 2019
Resolution: Updated FTP were properly followed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 July 2018
Resolved
Sheathing was found missing over port engine drive shaft at the bulkhead penetration resulting in large opening in aft engine room bulkhead. This condition would render use of CO2 fire fighting system ineffective. Replace sheathing prior to carrying passengers for hire.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2018
Resolution: Sheathing was located and installed.
Engineering › Reduction Gearing/Clutches › Hose
Issued 12 April 2018
Resolved
Machinery installed must be suitable for the vessel and its operation and for the purpose intended. Hydraulic line on starboard main engine/Z-drive was supported with string because it was vibrating loose and leaking. Make permanent repairs to ensure hose does not vibrate loose and leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2018
Resolved 2 May 2018
Resolution: Corrected
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, High Pressure (fuel injection)
Issued 12 April 2018
Resolved
Machinery installed must be suitable for the vessel and its operation and for the purpose intended. Also, Fuel lines must be protected from mechanical injury. Fuel hose on port main engine was found partially chafed through. Replace hose and ensure protection against chafing is installed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2018
Resolved 2 May 2018
Resolution: Corrected.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 30 March 2017
Resolved
Provide proof of testing materials to meet drug and alcohol requirements.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 31 March 2017
Resolution: Received email with pictures showing that the good alcohol test strips were onboard.
Lifesaving › Rescue Boat › Capacity
Issued 30 March 2017
Resolved
Rescue boat is not labeled with capacity of vessel, name on both sides and does not have reflective tape.
Condition: Improper/Lack of Maintenance
Due 30 April 2017
Resolved 31 March 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 30 March 2017
Resolved
All of the vessels ring buoys are missing retro-reflective tape.
Condition: Improper/Lack of Maintenance
Due 30 April 2017
Resolved 31 March 2017
Engineering › Thrusters › Blade
Issued 30 August 2016
Resolved
Vessel struck a submerged object. Dive survey showed cracked cowling and bent blades to stbd "Z" drive. OCMI authorized vessel to continue voyage and make repairs at next scheduled dry dock (January) unless there is a further reduction in propulsion. Where as the vessel will contact the local OCMI to coordinate repairs to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 26 November 2016
Resolution: z-drive was replaced.