Records from 2014 to 2026. Most recent: inspection, 26 June 2026.
Inspection history · 29
26 June 2026
PSC A
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8413717
28 April 2026
Administrative Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8358182
2 September 2025
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8225512
25 September 2024
MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8008991
13 December 2023
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7886386
11 August 2023
MARPOL Annex I Examination · Periodic Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7764862
2 August 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7758516
4 January 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7615907
30 March 2021
Damage Survey · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7194344
23 February 2021
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7150109
23 February 2021
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7150359
15 December 2020
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7112095
18 November 2020
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7097853
30 October 2020
Administrative Inspection · Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7086948
19 October 2020
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7080423
1 November 2019
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6846979
1 August 2019
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6768712
7 February 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6621757
1 November 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6575864
2 August 2018
Administrative Inspection · MARPOL Annex I Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6502360
25 July 2018
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6489218
9 February 2018
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6352429
15 September 2017
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6267471
14 July 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6208955
17 May 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6148202
31 August 2016
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5995816
2 August 2016
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5960605
21 January 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5790810
1 May 2014
Administrative Inspection · Construction Oversight · Initial Certification · Security Plan Review - VSP
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5014791
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 April 2026
Resolved
46 CFR 42.07-5
Load line marks to indicate the maximum amidship's draft to which a vessel can be lawfully submerged, in the various circumstances and seasons, shall be permanently marked on each side of the vessel in the form, manner, and location as required by this subchapter. Port and Stbd LL not permanetly affixed. Clear to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 19 May 2026
Resolution: Examined center-punched loadline symbols, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 August 2023
Resolved
Each OSV must carry not less than 12 rocket parachute flares; six (06) flares were expired.
46 CFR 133.60(b)
Action required: 10 - Deficiency Rectified
Resolved 11 August 2023
Resolution: Flares replaces.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 August 2023
Resolved
Each vessel must comply with 47 CFR part 80 as applicable; three (03) VHF radios did not have correct MMSI programmed.
46 CFR 130.210
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2023
Resolution: VHFs replaced with correct call sign programmed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 January 2023
Resolved
At least 2 lifebuoys each with self activating smoke signals must be stowed for quick release, for I service. No smoke quick release installed. Correct prior to returning to “I “ service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2023
Resolved 28 August 2023
Resolution: Bridge buoys installed.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 4 January 2023
Resolved
Line throwing appliance shall meet 160.040 and have an Aux line of at least 1500 ft. appliance onboard is approved under 160.031, which is only approved for “L” Service. Correct prior to returning to “I” service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2023
Resolved 28 August 2023
Resolution: Appropriate line throwing guns purchased.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 January 2023
Resolved
Paint locker required to have fixed extinguisher or if less than 200 cu ft a portable 40 B can be mounted outside. No extinguisher mounted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2023
Resolution: The fixed extinguisher mounted and hose repalced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 November 2020
Resolved
Where fire extinguishing systems or equipment are not required, but are installed, the system or equipment must be maintained in accordance with an appropriate industry standard and the manufacturer's specific guidance. Prove proper operation of the port and starboard fixed firefighting system / monitors.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2020
Resolved 15 December 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 November 2020
Resolved
Where fire extinguishing systems or equipment are not required, but are installed, the system or equipment must be maintained in accordance with an appropriate industry standard and the manufacturer's specific guidance. Prove proper of operation of the fire system strobe light in the galley deck area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 18 November 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 November 2020
Resolved
No flexible cord may be used except as allowed under Sections 400-7 and 400-8 of NFPA NEC 2002. Remove extension cords from the freezers and provide proper electrical junction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 18 November 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2020
Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he deems necessary to be assured of the safety and seaworthiness of the vessel. Make two leaking fasteners in the Engine Room overhead approximately 3 feet aft of the forward door watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 18 November 2020
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 2 November 2020
Resolved
In the inspection of hulls, the standards established by the American Bureau of Shipping shall be accepted as standard by the inspectors. ABS Rules for Building and Classing Steel Vessels Under 90 meters, Part 3, Chapter 2, Section 7.1.2 requires that access doors normally closed at sea are provided with a means on indicating on the bridge whether they are open or closed. The main deck forward hatch indicator switch was found inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 18 November 2020
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 19 October 2020
Resolved
Provide proof of structural integrity and NDT reports for satisfactory test of mast and struts and all related equipment/fasteners. Include masters statement to proper operations of all navigation lighting arrangements. Additionally, include repairs to hydraulic lines, tanks, and proper operation of equipment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 October 2020
Resolved 21 October 2020
Resolution: Received, reviewed, and accepted structural NDT report, satisfying the requirement.