MAURY USCG vessel records
← All vessels

SEA CYPRESS

Built
2014
Last inspected
30 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 30 June 2026
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2014–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH3758
1240991
Flag
UNITED STATES
Maury page id
psix-1240991

Documentation record

Registered dimensions (L × B × D)71.9 ft × 28.0 ft × 10.0 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)71.9 ft × 28.0 ft × 10.0 ft
ITC tonnageNot recorded
BuilderRODRIGUEZ SHIPBUILDING INC · CODEN, AL, UNITED STATES · built 2014
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMORGAN CITY, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 9 October 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 26 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 5 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

Inspection history · 26

30 June 2026 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8426257
10 February 2026 Bulk Liquid Transfer Monitor
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8455195
21 November 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8039583
8 April 2024 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7891620
16 May 2023 Damage Survey · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7690001
6 April 2023 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7663893
31 March 2023 Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7660432
31 March 2023 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7789742
2 March 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7644618
6 February 2023 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7632985
29 March 2022 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7420624
24 March 2022 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7418206
19 January 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7382557
19 April 2021 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7181773
30 November 2020 Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7101398
3 August 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6499693
28 July 2018 Examination of Repairs · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6495769
27 July 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6492117
24 July 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6490381
24 July 2018 Administrative Inspection · Damage Survey · Permit to Proceed
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6490402
11 June 2018 MTSA Verification · Industry Initiated Exam · Administration
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6441587
8 July 2016 MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5968603
4 February 2015 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5074749
31 January 2015 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5078892
7 October 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5001070
10 April 2014 Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4837253

Deficiency record · 9

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 April 2023 Resolved
(a) The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times. (b) Non-conformities and deficiencies must be corrected in a timely manner. Ensure all repairs completed meet sub chapter "M" requirements prior to departure.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2024
Resolved 30 June 2026
Resolution: MI attended vessel for 2026 annual and deemed vessel fit for route and service IAW sub M.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 February 2023 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. MI identified excessive oil and soot accumulation in overhead ventilation assembly above the stbd main engine and surrounding area. Remove accumulated oil.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 8 February 2023
Resolution: Received photos indicating area sufficiently cleaned.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 February 2023 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI identified Voltage selector adjustment switch missing on the main switchboard. Replace and install switch.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2023
Resolved 2 March 2023
Resolution: Recieved photograph of installtion of electrical panel voltage selector knob.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 February 2023 Resolved
The following systems must be equipped with gauges at the machinery location: (3) Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM. Neither generator has an RPM gauge installed. Install RPM gauge on both generators.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2023
Resolved 2 March 2023
Resolution: Received photos of installation of RPM guages on both generators.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 March 2022 Resolved
Vessel does not have a documented maintenance plan for the fuel system as required by 46 CFR 143.255(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 7 February 2023
Resolution: During Annual inspection verified Engine log book with maintenance plan.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 March 2022 Resolved
Vessel has no record of navigation assessment as required by 46 CFR 140.635
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 7 February 2023
Resolution: Verified nav assessment during annual COI inspection.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 March 2022 Resolved
Vessel has no record of emergency drills and instruction as required by 46 CFR 140.420
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 6 February 2023
Resolution: Verified ships record of drills during annual COI inspection.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 March 2022 Resolved
Vessel has no record of orentation for individuals that are not crew members as required by 46 CFR 140.415
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 6 February 2023
Resolution: Verified vessel records of orientation of individuals transiting on vessel during annual COI inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 July 2018 Resolved
Complete repairs to lower shaft tube damage caused by 24 JUL 2018 grounding, to the satisfaction of attending Marine Inspector prior to operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2018
Resolution: Repairs complete.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.