Records from 1992 to 2025. Most recent: operational control imposed, 1 July 2025.
Documentation record
Registered dimensions (L × B × D)59.0 ft × 21.0 ft × 8.9 ft
Registered tonnagegross 105 / net 71
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPHILLIP DITTA · MADISONVILLE, LA, UNITED STATES · built 1973
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPADUCAH, KY
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it105 - Regulatory (Subpart C or D), Gross Ton
71 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 13
1 July 2025
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8188174
22 May 2025
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8141594
17 February 2022
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7470707
16 September 2021
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7313900
23 August 2018
Initial Certification
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6524724
28 June 2016
Industry Initiated Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5923881
8 June 2011
Industry Initiated Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 4040375
19 April 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2628355
13 August 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 717162
5 March 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 27038
30 January 1998
Uninspected Towing Vessel
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 786656
17 November 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 70471
14 April 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 218134
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 23 August 2018
Resolved
Create a navigation assessment to be completed every time the vessel gets underway for the day. It must include the 13 items listed in this regulation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 23 August 2018
Resolved
The following alarms must be visible and audible in the pilothouse, have means to test, and continue until acknowledged. 1) Main engine low lube oil pressure. 2) Main engine high cooling water temp. 3) Generator low lube oil pressure. 4) Generator high water temp. 5) High bilge level. 6) Low hydraulic steering fluid level. 7) Low fuel level.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 August 2018
Resolved
Alcohol testing strips were expired. Replace with new test strips.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 August 2018
Resolved
Current placards on the navigation lights are not legible and we are not able to verify if they are of a coast guard approved type. Horn light doesn’t illuminate when horn is producing sound.
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 August 2018
Resolved
Need to move one type-1 life vest to the pilothouse
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 August 2018
Resolved
The lifeline on ring buoy must be buoyant, 60ft in length, non-kinking, diameter of at least 5/16 inch, and resistant to UV light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 August 2018
Resolved
Vessel needs to carry three red flare and three parachute red flares as visual distress signals. Must be stored on a portable watertight container marked with “DISTRESS SIGNALS”
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 August 2018
Resolved
Towing Vessel Record (TVR) logbook must be kept in accordance with this part. TVR must include the sections 1-10 listed
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
10 - Safety of Navigation › N/A - No Subsystem › Rate-of-turn indicator
Issued 23 August 2018
Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 August 2018
Resolved
The floating electric light must be under the approval series 161.010 or 161.110. The water light’s batteries were not an approved battery for the light. Use the markings on the water light and install with a battery matching the approved ones.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 23 August 2018
Resolved
Repair Crack in the Port side stern void to the satisfaction of attending Marine Inspector
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 23 August 2018
Resolved
Repair Internal Structure in stern void to the satisfaction of attending Marine Inspector. Severe wastage of structural members was observed by the Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 August 2018
Resolved
Covers missing on open circuits in breaker box
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 23 August 2018
Resolved
Missing Lagging on exhaust for Main engines and generators
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 August 2018
Resolved
Provide testing documentation for Safety Relief Valves on both Air Tanks
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 August 2018
Resolved
Link MMSI number into VHF radios
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 August 2018
Resolved
Repair weather tight doors on main deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 23 August 2018
Resolved
Repair Exhaust Leaks
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2018
Resolved 30 June 2022
Resolution: Cleared by earlier event.