MAURY USCG vessel records
← All vessels

DELAWARE

DELAWARE is a 2022 industrial vessel. The Coast Guard has recorded 10 inspections since 2018, most recently in July 2025, along with 4 deficiencies and 2 casualty investigations in 2022.

Records from 2018 to 2025. Most recent: inspection, 30 July 2025.

Built
2022
Last inspected
30 July 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 July 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM 7158
1266146
Flag
UNITED STATES
Maury page id
psix-1266146

Documentation record

Registered dimensions (L × B × D)273.6 ft × 62.0 ft × 14.0 ft
Registered tonnagegross 2,200 / net 2,200
ITC dimensions (L × B × D)273.6 ft × 62.0 ft × 14.0 ft
ITC tonnagegross 3,319 / net 995
BuilderBAY SHIPBUILDING CO · Sturgeon Bay, WI, UNITED STATES · built 2022
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 24 April 2026 · expires 30 April 2027
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3319 - Convention (Subpart B), Gross Ton
2200 - Regulatory (Subpart C or D), Gross Ton
995 - Convention (Subpart B), Net Ton
2200 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

Inspection history · 10

30 July 2025 Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8197979
23 June 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8156435
1 May 2025 Drydock Extension
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8126976
26 March 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7885148
28 June 2023 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7724708
18 August 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7538185
16 August 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7535331
4 August 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7529785
18 September 2020 Construction Oversight · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7080754
24 September 2018 Construction Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6547527

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 July 2025 Resolved
46 CFR 91.25-10: The inspection shall be such as to insure that the vessels fire-detecting is in satisfactory condition and fit for the service for which it is intended. Vessel had tape on 05 fire detectors. Ensure tape is removed from all fire detectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2025
Resolved 1 August 2025
Resolution: Recieved photographic proof that tape was removed. See photos documents.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 July 2025 Resolved
46 CFR 91.25-10: The inspection shall be such as to insure that the vessels extinguishing equipment is in satisfactory condition and fit for the service for which it is intended. Vessel had 01 fire hose with puncture. Punctured hose was removed from service and replace; corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 30 July 2025
Resolved 30 July 2025
Resolution: Repaced punctured hose with a new hose.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 26 March 2024 Resolved
Means shall be provided for stopping all fans in ventilation systems serving machinery and cargo spaces and for closing. Exhaust trunk #1 ventilation closures did not completely close.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2024
Resolved 22 April 2024
Resolution: Received Video was received showing full closure of damper from Port Engineer [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 26 March 2024 Resolved
Each vessel must have a line-throwing appliance approved under approval series 160.040. Vessel only had 1 Line throwing device instead of the 4 required by 46CFR160.040.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2024
Resolved 8 April 2024
Resolution: Picture of new line throwing canisters were emailed by Port Engineer [name withheld]

Casualty record · 2

4 August 2022Routine · role: Involved in a Marine Casualty · activity 7529785
18 August 2022Routine · role: Involved in a Marine Casualty · activity 7538185
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.