Records from 2014 to 2025. Most recent: inspection, 13 November 2025.
Documentation record
Registered dimensions (L × B × D)74.0 ft × 32.5 ft × 10.5 ft
Registered tonnagegross 212 / net 169
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHORIZON SHIPBUILDING INC · BAYOU LA BATRE, AL, UNITED STATES · built 2014
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 August 2026 · expires 30 September 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it212 - Simplified, Gross Ton
169 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 27
13 November 2025
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8267973
4 January 2025
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8060897
16 October 2024
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8019830
23 May 2024
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7917786
8 April 2024
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7889843
1 December 2022
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7602414
1 December 2022
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7604161
14 April 2022
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7430877
14 April 2022
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7430997
30 April 2019
Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6673460
13 April 2019
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6664597
10 January 2019
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6608765
10 December 2018
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6594996
6 November 2018
TPO Audit
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6575640
10 April 2018
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6403359
14 December 2017
MTSA Verification · Industry Initiated Exam · Administration
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6324852
10 December 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6327629
30 October 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6034183
25 June 2015
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5163771
12 May 2015
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5124180
21 April 2015
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5107955
1 January 2015
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5055509
14 November 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5023474
6 October 2014
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5000565
6 October 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5009654
30 September 2014
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4996755
7 August 2014
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4947159
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 4 January 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel alarm system malfunctioned. Provide TPO close out report prior to departure.
46CFR143.205
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2025
Resolution: Received TPO report.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 April 2024
Resolved
Each towing vessel have a self-priming, power-driven, fixed fire pump. Vessels fire pump was inoperable during inspection.
46 CFR 142.325 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2024
Resolution: Tech attended and repaired system - crew tested after repair (see docs)
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 8 April 2024
Resolved
There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. MI's unable to verify the primary
means of emergency dewatering (fixed system) functions as intended to include bilge suction.
46 CFR 140.210(a)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2024
Resolution: Crew demonstrated functionality of portable pumps, more to follow on this matter but 17 cleared.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 8 April 2024
Resolved
The safety of the towing vessel is the responsibility of the master and includes; Compliance with the applicable provisions of this subchapter and supervision of all persons onboard in carrying out their assigned duties. Crew onboard vessel unable to demonstrate familiarization and ability to utilize primary means of dewatering.
46 CFR 140.210 (a)(2)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2024
Resolution: Tech arrived on 4/9 and demonstrated use of fixed bilge system to vessel crew.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 8 April 2024
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. MI's unable to verify full functionality of the bilge system due to the inability to test bilge suction. Emergency dewatering system is tested every 3 months, but testing to ensure full functionality/functions as designed is not being completed in accordance with regulation, and procedural steps for testing as included in FT-51717.1 of the companies TSMS.
Company is required to have TPO conduct a external vessel audit. Scope of the audit shall include the verification that all essential systems, particularly the bilge and ballast system, are tested as required by 46 CFR 143.245. Additionally audit shall include verifying duties and duty stations of each person
onboard are identified IAW 46 CFR 140.405 and crews are
familiar with how to perform these duties. 72 hour notification prior to audit to be made to cognizant OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 December 2022
Resolved
Master reported that vessel lost port MDE while in process of mooring. Regulations require that propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems must: (1) Be maintained to ensure proper operation; (2) Be suitable for route and service; and (3) Have suitable propulsion controls to provide the operator full control at each operating station. Vessel will remain at McKinney Fleet (LMR 228) and have technicians attend for troubleshooting and repairs. Repairs will be cleared by TPO (TVIB), and reprot of repairs will be sent to CG.
Action required: 705 - Other - as specified
Resolved 3 January 2023
Resolution: Engine replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2019
Resolved
A continuous supply of clean fuel must be provided to main propulsion engines and generators.
Vessel has been draining and replacing fuel filters on board with increased frequency since April 4th, 2019, due to discovery of excessive water accumulation in the main engine fuel filters. Source/cause of excessive water in the fuel has not been identified and effectively corrected/isolated.
Vessel is allowed to continue voyage to Channahon, IL, however once there, the vessel is restricted from departing Channahon, IL until the source of excessive water contamination in the vessel's fuel is identified and steps are taken to correct the cause, and isolate/remove the water and/or contaminated fuel. After completing the above items, vessel must provide documentation of the above items and receive permission from CG MSU Chicago prior to departure from Channahon, IL.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 April 2019
Resolved 17 April 2019
Resolution: Evidence provided to validate issue corrected. See narative for additional details.