Records from 1993 to 2026. Most recent: inspection, 1 June 2026.
Documentation record
Registered dimensions (L × B × D)44.2 ft × 20.3 ft × 6.7 ft
Registered tonnagegross 52 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSNEED'S SHIPBUILDING INC · ORANGE, TN, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLAKE CHARLES, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Regulatory (Subpart C or D), Gross Ton
36 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 37
1 June 2026
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8385651
9 April 2026
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8345494
13 March 2026
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8325588
2 March 2026
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8318638
16 February 2026
Drydock Extension · COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8309306
13 November 2025
Uninspected Other
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8268282
23 October 2025
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8257839
4 April 2023
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 7662545
29 March 2023
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7659250
1 October 2020
Initial Certification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7069479
21 July 2020
TPO Audit
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7013167
10 January 2019
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6608765
19 September 2017
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 6270622
2 December 2016
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 6051161
8 March 2016
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5836057
2 October 2015
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 5734545
28 May 2015
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 5141340
18 March 2013
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4552956
11 December 2012
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 4532225
3 June 2012
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4347669
28 March 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4273846
14 December 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3921441
6 April 2010
Deficiency Check · MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3711839
2 November 2009
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3626753
18 July 2007
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2999798
2 March 2007
Examination of Repairs · Uninspected Other · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2880809
2 March 2007
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3023294
6 September 2006
MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2771049
10 February 2006
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2584211
8 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979097
4 April 2001
Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 1522541
10 April 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 17402
17 February 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 274907
5 January 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 273535
7 August 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 21062
15 May 1997
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 404084
21 December 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 117924
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 February 2026
Resolved
The following items must be performed and properly recorded:
- Orientation of individuals that are part of the crew and not part of the crew
- Emergency drills and instruction
- Health and Safety training
When the above have been completed over the course of the next 30 days, submit objective evidence to this office.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2026
Resolved 13 March 2026
Resolution: Received objective evidence of record keeping
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 16 February 2026
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment. Conduct and record navigation assessments to include the information required in 46 CFR 140.635. Submit objective evidence of navigation assessments being completed to this office.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2026
Resolved 13 March 2026
Resolution: Received objective evidence that nav assessments are being completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 February 2026
Resolved
Essential systems or equipment must be regularly tested and examined. Provide objective evidence, to this office, that the tests required by Table 143.245(b) have been performed in the intervals required by the table.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2026
Resolved 9 April 2026
Resolution: Received report from Rio Marine for tsteing of all alarm setpoints.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 February 2026
Resolved
Pressure vessels over 5 cubic feet must be fitted with a relief valve that prevents the pressure from exceeding 10 percent of the pressure vessel's MAWP. The pressure vessel in the engine room has a relief valve with a set point of relief was 100 psi more than the pressure vessel MAWP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2026
Resolved 6 March 2026
Resolution: Third party installed lower set relief valve.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 February 2026
Resolved
All portable, semi-portable fire extinguishers and fixed fire detection systems must be inspected/tested at least once every 12 months. Provide objective evidence to this office that the onboard extinguishers and detection system has been inspected/tested.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2026
Resolved 2 March 2026
Resolution: Completed annual inspection of fire extinguishers and fixed fire detection system. Documents uploaded.
Construction/Loadline › Hull › Weld
Issued 2 March 2007
Resolved
Repair/ replace fracture in aft/ port side taft rail
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 March 2007
Resolution: COMPLETED REPAIR.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 2 March 2007
Resolved
Replace Lifejacket found to have broken latch system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 March 2007
Resolved 6 March 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 2 March 2007
Resolved
Ensure Emergency fuel shutoff is located outside of space.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 6 March 2007
Deck/Cargo › Cargo Stowage › General
Issued 2 March 2007
Resolved
Ensure portable gas bottles are chained down in lieu of tied loosely with line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 March 2007