Records from 2014 to 2026. Most recent: inspection, 4 May 2026.
Documentation record
Registered dimensions (L × B × D)122.9 ft × 38.0 ft × 12.0 ft
Registered tonnagegross 712 / net 213
ITC dimensions (L × B × D)122.9 ft × 38.0 ft × 12.0 ft
ITC tonnagegross 712 / net 213
BuilderNEWSOUTH MARINE CONSTRUCTION INC · GREENVILLE, MS, UNITED STATES · built 2014
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portVICKSBURG, MS
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 March 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it712 - Convention (Subpart B), Gross Ton
213 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 27
4 May 2026
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8361781
4 May 2026
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8368474
9 September 2024
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7999377
9 September 2024
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8016673
29 November 2023
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7831490
29 November 2023
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7831656
28 April 2023
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7677320
17 October 2022
COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7596039
30 June 2022
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7488845
23 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7458047
29 March 2021
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7134047
24 January 2020
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6895731
29 October 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6844670
26 September 2018
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6555807
9 May 2017
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6142824
28 April 2017
Administrative Inspection · DAPI Audit
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6137548
3 March 2017
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6112339
13 December 2016
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6057598
22 August 2016
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5979734
14 April 2016
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6038462
25 January 2016
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5805318
7 August 2015
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5208759
6 April 2015
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5098053
3 December 2014
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5033670
17 October 2014
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5008768
25 June 2014
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4899688
8 June 2014
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4883912
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 May 2026
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: (1) Be maintained to ensure proper operation;(2) Be suitable for route and service; and(3) Have suitable propulsion controls to provide the operator full control at each operating station. Vessel has a sheared bulking coupling resulting in inability to safely utilize starboard-side propulsion.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 May 2026
Resolution: Received mechanic's report of replaced bulking coupling and test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 November 2023
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: (1) be maintained to ensure proper operation.
The port MDE drive coupling to the reduction gear failed. Make repairs to the satisfaction of the TPO. Provide objective evidence of repairs to the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 29 November 2023
Resolved 30 November 2023
Resolution: Received objective evidence of satisfactory repairs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 June 2022
Resolved
A remote fuel shut off valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine. The wire rope for the starboard main engine fuel shut off valve parted while testing, rendering it inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2022
Resolved 30 June 2022
Resolution: Engineer reattached wire rope and showed proper operation of valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 June 2022
Resolved
Electrical systems must be designed and maintained for safe operation of the towing vessel and safety of persons on board. The battery charger for the battery bank located on upper engine room starboard side is connected to the batteries with gator clips.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2022
Resolved 6 July 2022
Resolution: Received pictures showing battery charger cables were changed to have ring terminals.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 June 2022
Resolved
Electrical systems must be designed and maintained for safe operation of the towing vessel and safety of persons on board. The DC panel in upper engine room starboard side is missing blanks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2022
Resolved 6 July 2022
Resolution: Blanks installed in DC breaker panel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 May 2022
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. The company failed to undergo an annual inspection within 3 months before and after the COI anniversary date.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2022
Resolved 30 June 2022
Resolution: Annual inspection completed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 October 2019
Resolved
Fire pump not capable of supplying adequate water.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2019
Resolution: The pump was rebuilt.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 October 2019
Resolved
The fuel shutoff valve could not be operated from outside the space. The conduit, which housed the cable for the shutoff valve, detached from the wall when attempting to operate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 November 2018
Resolved
A B-II portable extinguisher must be located near the storage room for flammable and combustible materials.
Action required: 10 - Deficiency Rectified
Due 12 November 2018
Resolved 6 November 2018
Resolution: A B-II extinguisher was placed on the bulkhead next to the storage room.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 November 2018
Resolved
The frame of a semi portable B-V must be permanently attached to a bulkhead or deck.
Action required: 10 - Deficiency Rectified
Due 12 November 2018
Resolved 6 November 2018
Resolution: Chain welded to bulkhead on second deck to hold B-V.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 26 September 2018
Resolved
Supplemental flashing red light in lower engine room and in aft steering not operating. Repair/replace supplemental flashing red light in those locations.
Action required: 10 - Deficiency Rectified
Due 6 November 2018
Resolved 6 November 2018
Resolution: Supplemental flashing red lights have been replaced.