Records from 2014 to 2026. Most recent: inspection, 28 January 2026.
Documentation record
Registered dimensions (L × B × D)348.0 ft × 62.0 ft × 24.5 ft
Registered tonnagegross 4,530 / net 4,530
ITC dimensions (L × B × D)348.0 ft × 62.0 ft × 24.5 ft
ITC tonnagegross 4,311 / net 2,505
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2014
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portBALTIMORE, MD
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4530 - Simplified, Gross Ton
4530 - Simplified, Net Ton
4311 - Convention (Subpart B), Gross Ton
2505 - Convention (Subpart B), Net Ton
10035 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
28 January 2026
Examination of Repairs · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8302876
16 September 2024
Drydock Exam · COI Inspection · Internal Structural Exam · Deficiency Check · Cargo Tank Internal
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8003323
18 January 2024
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7851359
23 February 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7640867
19 January 2023
Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7623542
22 September 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7564654
14 October 2021
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7332489
21 October 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7085167
28 December 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6895638
21 October 2019
Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6834797
16 October 2019
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6836026
17 September 2018
Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6542055
5 February 2018
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6349471
4 October 2017
Periodic Inspection · Deficiency Check · MTSA Verification · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6280888
6 April 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6166717
5 November 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6035711
20 September 2016
Annual Inspection · Deficiency Check · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6004841
1 December 2015
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5773977
2 August 2015
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5203867
2 August 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5204771
2 March 2015
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5076765
21 October 2014
Administrative Inspection · Hull Examination · Initial Certification · Cargo Tank Internal · Construction Oversight · Internal Structural Exam · MTSA Verification · MARPOL Annex VI Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5009576
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 28 January 2026
Resolved
Before making any repairs to boilers or unfired pressure vessels, the Chief Engineer must submit a report covering the nature of the repairs to the Officer in Charge, Marine Inspection, at or nearest to the port where the repairs are to be made. MI was notified by SSF Command Center that two pinhole leaks in the tank piping arrangement led to leaking on-deck and inoperable thermal fluid heater. Provide a repair proposal to the satisfaction of the [name withheld] the thermal fluid heater is available for testing in the presence of a marine inspector. Rectify prior to operation of Thermal Fluid Heater.
(46 CFR 35.25-5)(a) 705c
Action required: 705 - Other - as specified
Due 11 February 2026
Resolved 18 February 2026
Resolution: Witnessed repairs to expansion tank. Witnessed operation of thermal fluid heater.
Deck/Cargo › Cargo Heating › General
Issued 4 October 2017
Resolved
Prove proper operation of thermal fluid heater and shutdown tests.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 5 February 2018
Resolution: Test complete of low thermal fluid alarm. All other tests were completed under actibity #6280888.
Electrical › Electrical Distribution System (service) › Conductor
Issued 20 September 2016
Resolved
Remove daisy-chained surge protectors above refrigerator in accom. space.
Due 20 October 2016
Resolved 10 November 2016
Electrical › Electrical Distribution System (service) › Conductor
Issued 20 September 2016
Resolved
Remove daisy chained surge protector in crew berthing
Due 20 October 2016
Resolved 10 November 2016
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 20 September 2016
Resolved
MMark Emergency Escape Hatch handle with direction of use.
Condition: Design Flaw
Due 20 October 2016
Resolved 10 November 2016
Fire Fighting › Means of Escape › Blocked
Issued 20 September 2016
Resolved
Mark bulkhead at emergency escape hatch hatch "Keep Clear"
Condition: Design Flaw
Due 20 October 2016
Resolved 10 November 2016
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 September 2016
Resolved
Provide documentation for crew members conducting monthly fire and abandon ship drills.
Condition: Improper Installation
Due 20 October 2016
Resolved 10 November 2016
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle, Spare
Issued 20 September 2016
Resolved
Spare SCBA bottle must be charged to full capacity
Condition: Improper/Lack of Maintenance
Due 20 October 2016
Resolved 10 November 2016
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 1 December 2015
Resolved
Vessel must install fuel oil drip sampler.
Action required: 705 - Other - as specified
Due 30 December 2015
Resolved 1 December 2015
Resolution: Vessel installed drip sampler.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Gaskets
Issued 1 December 2015
Resolved
Vessel must replace starboard cargo pump gasket at the deckhouse. Gasket is dry rotted and cracked. Vessel must replace this gasket prior to using this pump.
Action required: 705 - Other - as specified
Resolved 1 December 2015
Resolution: Vessel replaced gasket.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 August 2015
Resolved
Isolate and tag out circuits on all damaged deck and navigation lights and make permanent repairs prior to use.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 September 2015
Resolved 6 August 2015
Resolution: Repairs to forward mast, navigation lights, and deck lighting are complete. Turned on all lights and tested the ground detection on the 120v distribution panel for nav lights and deck lighting. All sat.