Records from 2014 to 2026. Most recent: inspection, 19 May 2026.
Inspection history · 30
19 May 2026
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8376597
15 April 2026
COC-MODU Annual
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8352623
3 December 2025
COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8279190
19 May 2025
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8140604
26 March 2025
In-Service Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8100090
26 September 2024
In-Service Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8020933
25 September 2024
Deficiency Check
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8020300
4 September 2024
In-Service Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7998123
13 August 2024
Deficiency Check
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7991447
12 August 2024
Deficiency Check
Physical examination · Outer Continental Shelf National Center of Expertise · Activity 7981914
6 August 2024
In-Service Inspection
Physical examination · Outer Continental Shelf National Center of Expertise · Activity 7975824
11 June 2024
COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7941785
6 June 2023
COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7706298
11 May 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7686454
8 November 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7594418
19 May 2022
ISPS Exam · Ballast Water Examination · COC-MODU Renew
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7458915
6 April 2022
PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7426088
12 March 2022
Damage Survey · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7410628
12 March 2022
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7411989
2 January 2022
VRP Review · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7374582
28 December 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7373250
5 December 2019
COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6882310
7 September 2018
Administrative Inspection · COC-MODU Renew
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6535318
19 January 2018
COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6535234
22 May 2017
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6152844
18 April 2017
In-Service Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6130828
6 September 2016
COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6055230
23 October 2015
COC-MODU Annual
Type not classified · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5736358
7 October 2014
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4989272
3 October 2014
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4998385
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 6 August 2024
Resolved
Should an incident occur, or a defect be discovered, which affects the safety of the unit or the efficiency or completeness of the structure, equipment, fittings, arrangements or materials, the person in charge or the owner of the unit should report the incident or defect at the earliest opportunity to the Administration... If the unit is in an area under the jurisdiction of another Government, the person in charge or the owner of the unit should also report the incident or defect immediately to the appropriate authorities of the port or coastal State and the nominated surveyor or recognized organization should ascertain that such a report has been made. The report referenced in deficiency no. 1 report was made to the coastal State five days after the damage was sustained and the lifeboat was out of service. At time of coastal State notification, Valaris acknowledged that the Administration had not yet been notified. Provide documentation on how notifications complying with this cite were made and if the Safety Management System sufficiently addresses how the "ship is maintained in conformity with the provisions of relevant rules and regulations". If determined to be non-compliant, provide intent on how future notifications are to be made "at the earliest opportunity to the Administration" and "immediately to the appropriate authorities of the port or coastal State".
Cite: 09 MODU 1.6.6.3; 20 SOLAS IX/3.1; ISM 1.2.3.2, 10.1.
Action: 16a,b,c.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2024
Resolution: Master provided summary of the reporting process related to this particular incident. Intent was to draw attention to 09 MODU 1.6.6.3 for coastal State notification with verification of same by RO.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 6 June 2023
Resolved
The bridge navigational watch system (BNWAS) shall be in operation whenever the ship is underway at sea. BNWAS found powered down and crew states BNWAS is not used while on DP.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 8 June 2023
Resolution: Master/OIM provided statment attesting to continued use of BNWAS.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Technical files and if applicable, monitoring manual
Issued 6 June 2023
Resolved
The survey of marine diesel engines and equipment for compliance with MARPOL Regulation 13 of Annex VI shall be conducted IAW with the revised NOx Technical Code 2008. Crew has not logged replacement of the parts/components which, when used in the engine will result in the continued compliance of the engine with the NOx emission limits in the EIAPP required technical files.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
Resolution: Master/OIM provided statements from ABS and crew will begin completing NOx technical file updates as required.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 12 March 2022
Resolved
The condition of the ship and it equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Following a reported marine casualty, marine inspectors found damage to electrical and lifesaving equipment, and other systems. PSCO requires vessel to be surveyed to assess damages and attest to repairs prior to departing the COTP zone.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2022
Resolved 6 April 2022
Resolution: Reviewed the class report, divers report, and witnessed onboard the vessel of satisfactory repairs. All satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 12 March 2022
Resolved
Ships shall be maintained in compliance with the structural, mechanical, and electrical requirements of a classification society which is recognized by the Administration. Following a reported marine casualty, marine inspectors identified structural damage to the starboard section of the vessel including but not limited to decks, vertical supports, overheads, and cross beams. PSCO requires vessel to be surveyed to assess damages and attest to repairs prior to departing the COTP Zone.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2022
Resolved 6 April 2022
Resolution: Reviewed the class report, divers report, and witnessed onboard the vessel of satisfactory repairs. All satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 12 March 2022
Resolved
Guard rails or bulwarks shall be fitted around all exposed decks. Following a reported marine casualty, marine inspectors found damaged/destroyed handrails on starboard side of vessel. Repair handrails to satisfaction of the RO.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2022
Resolved 6 April 2022
Resolution: Reviewed the class report, divers report, and witnessed onboard the vessel of satisfactory repairs. All satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 3 January 2020
Resolved
Load lines shall be permanently affixed in a contrasting color to the hull. Load line Plimsoll marks are not visible as presented.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 3 January 2020
Resolution: OIM sent photos of power washed Plimisoll marks w/contrasting color.
Lifesaving › Lifeboat › Markings
Issued 23 October 2015
Resolved
L/Bs located aft have faded retro-reflective tape. Retro-refelctive material shall be fitted on all lifesaving appliances IAW the recommendations of the organization. LSA Code 1.2.27
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 29 October 2015
Resolution: Brought new retro tape on board, replaced faded retro. [name withheld] submitted pictures.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 October 2015
Resolved
Downward facing embarkation light extingusihed at L/B #1 Sation. The area of water into a survival craft is launched shall be adequately illuminated by emergency lighting. [09 MODU Code 10.7.6]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2015
Resolved 26 October 2015
Resolution: Lightbulbs have been replaced. Pictures were sent from [name withheld] to MI's.
Lifesaving › Lifeboat › Propulsion Engine
Issued 23 October 2015
Resolved
Two forward lifeboats had not been drained and refilled with fresh fuel since JULY 2014 (over 1 year). Annual inspection of L/B's shall include emptying and cleaning each fuel tank, and refilling it with fresh fuel. [46 CFR 109.301(f)(1)]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 29 October 2015
Resolution: Stripped, refilled with fresh fuel on L/Bs. [name withheld] forwarded MI's copy of work order in PMS.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 October 2014
Resolved
Stairways which penetrate more than a single deck should be protected by self closing doors at all levels. Stairway doors are not self closing. Adjust doors so that they are self closing.
Action required: 705 - Other - as specified
Due 9 November 2014
Resolved 24 October 2014
Resolution: Received email stating that all stairwell fire doors had been repaired and now properly close.