MAURY USCG vessel records Sign in
← All vessels

VALARIS DS-16

VALARIS DS-16 is a 2014 mobile offshore drilling unit. The Coast Guard has recorded 30 inspections since 2014, most recently in May 2026, along with 11 deficiencies and 1 operational control.

Records from 2014 to 2026. Most recent: inspection, 19 May 2026.

Built
2014
Last inspected
19 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9630078 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1291926
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1291926

Inspections, by type

…with no type recorded4
Years with a record 12 calendar years (2014–2026)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it52242 - Convention (Subpart B), Gross Ton
15672 - Convention (Subpart B), Net Ton
33418 - Dead Weight, Metric Ton
70458 - Displacement, Metric Ton
52242 - Simplified, Gross Ton
15672 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DEEPSTIM AMERICA Industrial Vessel · MISLE 1167069 · 8 November 2022 · activity 7594418SARAH GOLDING Towing Vessel · MISLE 1274953 · 12 March 2022 · activity 7411989AKTI Freight Ship · MISLE 1276979 · 12 March 2022 · activity 7411989MICHELLE GOLDING Towing Vessel · MISLE 1325679 · 12 March 2022 · activity 7411989HARVEY SBISA Towing Vessel · MISLE 1339634 · 12 March 2022 · activity 7411989

Inspection history · 30

19 May 2026 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8376597
15 April 2026 COC-MODU Annual
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8352623
3 December 2025 COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8279190
19 May 2025 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8140604
26 March 2025 In-Service Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8100090
26 September 2024 In-Service Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8020933
25 September 2024 Deficiency Check
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8020300
4 September 2024 In-Service Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7998123
13 August 2024 Deficiency Check
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7991447
12 August 2024 Deficiency Check
Physical examination · Outer Continental Shelf National Center of Expertise · Activity 7981914
6 August 2024 In-Service Inspection
Physical examination · Outer Continental Shelf National Center of Expertise · Activity 7975824
11 June 2024 COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7941785
6 June 2023 COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7706298
11 May 2023 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7686454
8 November 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7594418
19 May 2022 ISPS Exam · Ballast Water Examination · COC-MODU Renew
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7458915
6 April 2022 PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7426088
12 March 2022 Damage Survey · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7410628
12 March 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7411989
2 January 2022 VRP Review · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7374582
28 December 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7373250
5 December 2019 COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6882310
7 September 2018 Administrative Inspection · COC-MODU Renew
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6535318
19 January 2018 COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6535234
22 May 2017 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6152844
18 April 2017 In-Service Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6130828
6 September 2016 COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6055230
23 October 2015 COC-MODU Annual
Type not classified · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5736358
7 October 2014 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4989272
3 October 2014 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4998385

Deficiency record · 11

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 6 August 2024 Resolved
Should an incident occur, or a defect be discovered, which affects the safety of the unit or the efficiency or completeness of the structure, equipment, fittings, arrangements or materials, the person in charge or the owner of the unit should report the incident or defect at the earliest opportunity to the Administration... If the unit is in an area under the jurisdiction of another Government, the person in charge or the owner of the unit should also report the incident or defect immediately to the appropriate authorities of the port or coastal State and the nominated surveyor or recognized organization should ascertain that such a report has been made. The report referenced in deficiency no. 1 report was made to the coastal State five days after the damage was sustained and the lifeboat was out of service. At time of coastal State notification, Valaris acknowledged that the Administration had not yet been notified. Provide documentation on how notifications complying with this cite were made and if the Safety Management System sufficiently addresses how the "ship is maintained in conformity with the provisions of relevant rules and regulations". If determined to be non-compliant, provide intent on how future notifications are to be made "at the earliest opportunity to the Administration" and "immediately to the appropriate authorities of the port or coastal State". Cite: 09 MODU 1.6.6.3; 20 SOLAS IX/3.1; ISM 1.2.3.2, 10.1. Action: 16a,b,c.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2024
Resolution: Master provided summary of the reporting process related to this particular incident. Intent was to draw attention to 09 MODU 1.6.6.3 for coastal State notification with verification of same by RO.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 6 June 2023 Resolved
The bridge navigational watch system (BNWAS) shall be in operation whenever the ship is underway at sea. BNWAS found powered down and crew states BNWAS is not used while on DP.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 8 June 2023
Resolution: Master/OIM provided statment attesting to continued use of BNWAS.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Technical files and if applicable, monitoring manual
Issued 6 June 2023 Resolved
The survey of marine diesel engines and equipment for compliance with MARPOL Regulation 13 of Annex VI shall be conducted IAW with the revised NOx Technical Code 2008. Crew has not logged replacement of the parts/components which, when used in the engine will result in the continued compliance of the engine with the NOx emission limits in the EIAPP required technical files.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
Resolution: Master/OIM provided statements from ABS and crew will begin completing NOx technical file updates as required.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 12 March 2022 Resolved
The condition of the ship and it equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Following a reported marine casualty, marine inspectors found damage to electrical and lifesaving equipment, and other systems. PSCO requires vessel to be surveyed to assess damages and attest to repairs prior to departing the COTP zone.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2022
Resolved 6 April 2022
Resolution: Reviewed the class report, divers report, and witnessed onboard the vessel of satisfactory repairs. All satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 12 March 2022 Resolved
Ships shall be maintained in compliance with the structural, mechanical, and electrical requirements of a classification society which is recognized by the Administration. Following a reported marine casualty, marine inspectors identified structural damage to the starboard section of the vessel including but not limited to decks, vertical supports, overheads, and cross beams. PSCO requires vessel to be surveyed to assess damages and attest to repairs prior to departing the COTP Zone.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2022
Resolved 6 April 2022
Resolution: Reviewed the class report, divers report, and witnessed onboard the vessel of satisfactory repairs. All satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 12 March 2022 Resolved
Guard rails or bulwarks shall be fitted around all exposed decks. Following a reported marine casualty, marine inspectors found damaged/destroyed handrails on starboard side of vessel. Repair handrails to satisfaction of the RO.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2022
Resolved 6 April 2022
Resolution: Reviewed the class report, divers report, and witnessed onboard the vessel of satisfactory repairs. All satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 3 January 2020 Resolved
Load lines shall be permanently affixed in a contrasting color to the hull. Load line Plimsoll marks are not visible as presented.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 3 January 2020
Resolution: OIM sent photos of power washed Plimisoll marks w/contrasting color.
Lifesaving › Lifeboat › Markings
Issued 23 October 2015 Resolved
L/Bs located aft have faded retro-reflective tape. Retro-refelctive material shall be fitted on all lifesaving appliances IAW the recommendations of the organization. LSA Code 1.2.27
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 29 October 2015
Resolution: Brought new retro tape on board, replaced faded retro. [name withheld] submitted pictures.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 October 2015 Resolved
Downward facing embarkation light extingusihed at L/B #1 Sation. The area of water into a survival craft is launched shall be adequately illuminated by emergency lighting. [09 MODU Code 10.7.6]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2015
Resolved 26 October 2015
Resolution: Lightbulbs have been replaced. Pictures were sent from [name withheld] to MI's.
Lifesaving › Lifeboat › Propulsion Engine
Issued 23 October 2015 Resolved
Two forward lifeboats had not been drained and refilled with fresh fuel since JULY 2014 (over 1 year). Annual inspection of L/B's shall include emptying and cleaning each fuel tank, and refilling it with fresh fuel. [46 CFR 109.301(f)(1)]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 29 October 2015
Resolution: Stripped, refilled with fresh fuel on L/Bs. [name withheld] forwarded MI's copy of work order in PMS.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 October 2014 Resolved
Stairways which penetrate more than a single deck should be protected by self closing doors at all levels. Stairway doors are not self closing. Adjust doors so that they are self closing.
Action required: 705 - Other - as specified
Due 9 November 2014
Resolved 24 October 2014
Resolution: Received email stating that all stairwell fire doors had been repaired and now properly close.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.