MAURY USCG vessel records
← All vessels

KATHRYN B

Built
1975
Last inspected
18 August 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 18 August 2025
…with no type recorded19
Operational controls None recorded without a removal date
Years with a record 20 calendar years (1992–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE2619
137775
Flag
UNITED STATES
Maury page id
psix-137775

Documentation record

Registered dimensions (L × B × D)99.2 ft × 22.1 ft × 7.9 ft
Registered tonnagegross 156 / net 106
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALBERT BERNERT INC · TROUTDALE, OR, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Endorsements, as the file codes themcw_un
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it156 - Regulatory (Subpart C or D), Gross Ton
106 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 35 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 13 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 13

Inspection history · 35

18 August 2025 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8239938
6 August 2025 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8204068
12 February 2025 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8058811
12 July 2024 COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7956749
14 August 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7764939
6 September 2022 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7553428
8 August 2022 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7523952
7 October 2021 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7328625
3 September 2021 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7306380
12 August 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7285029
13 July 2021 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8067449
23 June 2021 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7236039
17 August 2020 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7035351
12 June 2020 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6985173
8 January 2020 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6890393
30 October 2019 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6854364
5 August 2019 Initial Certification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6676056
9 March 2017 Industry Initiated Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6102125
23 April 2014 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4842324
13 April 2014 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4842163
22 August 2013 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4694428
20 March 2013 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4558454
23 April 2011 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3994037
11 March 2011 Industry Initiated Exam · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3963619
11 September 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3326821
22 March 2005 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2317077
19 October 2004 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2224246
27 August 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 80649
14 April 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 155897
6 June 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 65927
10 June 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 50092
5 March 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 125826
14 June 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 136927
24 May 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 186817
24 May 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 220065

Deficiency record · 15

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2025 Resolved
46 CFR 140.610(a) - All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding. Marine Inspector observed an excessive amount of water accumulation in the engine room bilge from the port and starboard shaft seals. Packing glands were found fastened almost completely tight. Replace packing to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2025
Resolved 18 August 2025
Resolution: attended vessel in water. Seals have had additional packing added to slow the leak.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 August 2023 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: High bilge levels. Void spaces 1,2,3 do not have functioning bilge alarms. Ensure all bilge alarms function and alarm at the operating station to the satisfaction of the Marine Inspector.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2023
Resolved 29 August 2023
Resolution: Tested bilge alarms in voids 1, 2, & 3. All operational and correctly identified individually in the wheelhouse.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 August 2023 Resolved
All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Bilge suction piping is missing check/foot valve. Install check/foot valve on all bilge suction piping to the satisfaction of the Marine Inspector.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2023
Resolved 8 September 2023
Resolution: Check vlaves were added to bilge overboard piping.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 August 2023 Resolved
Each distribution panel or switchboard on a towing vessel must be totally enclosed and of the dead front type. Inspector fund a breaker box closed with duct tape. Latch was inoperable and open breaker slots were exposed. Repair to satisfaction of marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2023
Resolved 29 August 2023
Resolution: Electrical box in engineering space properly closed to cover exposed breaker slots with a dead front cover.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 August 2023 Resolved
Each vessel must be designed and constructed to minimize fire hazards insofar as reasonable and practicable. Inspector asked master and crew how to block large ventilation tubing from engine room in the event of a fire. Crew did not have a solution. Repair to satisfaction of Marine Inspector.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2023
Resolved 8 September 2023
Resolution: Large culvert above engine room was sealed with metal and firestop.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 14 August 2023 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property and the environment. Emergency exit in auxillary machinery space was blocked with lube oil drums inside space. Remove all obstacles from egress route to the satisfaction of the Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2023
Resolved 29 August 2023
Resolution: Emergency egress route in Aux. machinery space cleared of oil drums.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 August 2022 Resolved
Emergency lighting must be provided for all internal crew working and living areas. No emergency lighting was present in the second deck accommodation space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2022
Resolved 6 September 2022
Resolution: Verified installation of emergency lighting and witnessed a satisfactory operational test.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 8 August 2022 Resolved
Auxiliary generator engine low lube oil pressure and high cooling water temperature must be tested twice in every 5 years, with no more than 3 years elapsing since last test. Vessel had no record of testing these alarms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2022
Resolved 6 September 2022
Resolution: Witnessed an operational test of both auxiliary generator's high jacket water and low l/o pressure alarms with a visible and audible alarm at the operating station.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 August 2022 Resolved
Vessels engaged in towing exclusively on navigable waters of the US must carry current or currently corrected charts. Existing charting system was last updated August 21, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2022
Resolved 6 September 2022
Resolution: Verified vessel's Rose Point navigation system was updated and had available the most current charts.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 8 August 2022 Resolved
Each towing vessel operator must hold a Restricted Radio Operator license or higher. Vessel's operator did not an FCC Radio Operator's permit of any grade.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2022
Resolved 6 September 2022
Resolution: Operator onboard had a valid radio operator's license.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 August 2021 Resolved
Fire detection systems. The system is installed, tested, and maintained in accordance with the manufacturer's design manual. The vessel's fire detection system has a General Trouble alarm on the panel. Identify and correct alarm cause and provide technician report to our office prior to towing operations.
Action required: 705 - Other - as specified
Resolved 13 August 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 August 2021 Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Vessel has fuel oil in storage room bilge aft of the forward fuel tank. Clean fuel oil from bilge to the satisfaction of a CG Marine Inspector prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2021
Resolution: Received objective evidence showing fuel oil has been removed and bilges cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 August 2021 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel's generator space is filled with combustion gases due to excessive engine blowby. Identify root cause and repair to the satisfaction of a CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 7 October 2021
Resolution: Vessel installed filter system on both generators to collect excess combustion gasses from oil blow-by system.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 August 2021 Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. Vessel has missing smoke detectors in berthing areas on the Texas Deck and Main Deck. Install smoke detectors in all berthing areas to the satisfaction of a CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 13 August 2021
Resolution: Received objective evidence showing new smoke detectors installed in berthing areas.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 August 2020 Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, fired-detection systems, and fixed fire-extinguishing systems, must be inspected or tested at least once every 12 months. Multiple fire extinguishers onboard the vessel were found to not have received their annual servicing conducted for 2020. The last inspection conducted for the un-serviced extinguishers occurred in March 2019. Ensure fire extinguishers are serviced and properly marked. Complete by 16 Sep 2020.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2020
Resolved 19 August 2020
Resolution: Company representative submitted a fire equipment-servicing certificate and photographic evidence attesting to the servicing of each of the deficient fire extinguishers identified during the annual inspection on 17Aug20.