Records from 2017 to 2026. Most recent: inspection, 28 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 24
28 April 2026
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8330807
7 April 2026
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8344461
23 April 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8117980
9 May 2024
Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7909706
21 February 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7868352
21 February 2023
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7638003
26 November 2022
Damage Survey · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7599621
25 November 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7602989
18 May 2022
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7465976
4 April 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7427606
2 March 2022
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7403596
2 March 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7473362
2 November 2021
Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7362171
6 October 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7332228
23 February 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7145217
20 August 2020
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7032579
1 March 2020
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6926361
10 February 2020
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6925705
5 February 2020
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6906378
1 February 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6618683
16 January 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6611171
5 November 2018
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6539170
19 March 2018
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6374905
17 May 2017
Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6271311
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 April 2026
No resolution recorded
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Marine inspector identified a 1" x 36" discontinuity in bulkhead separating starboard void forward of engine room and tank space. Submit repair proposal to be reviewed and approved by the attending USCG marine inspector. Owner/operator is required to notify Sector Honolulu Inspections requesting attendance no later than two weeks (14 days) prior to conducting repair. Repair to the satisfaction of the attending marine inspector no later than 30 Sep 2026 when vessel undergoes non-credit dry dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 September 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 May 2024
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Vessel has swim deck held in place by pins. Pins bolted with dissimilar metals, causing excessive corrosion where pins are bolted to swim deck. Submit repair proposal to be reviewed and approved by the attending USCG marine inspector.
46 CFR46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 30 May 2024
Resolution: Vessel welded new mounting plates and added a teflon barrier between stainless steel pins and aluminum mounting plate. Weight test satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 9 May 2024
Resolved
A hatch exposed to the weather must be watertight. Hatch on main deck leading into compartment above wing deck not watertight and allowing water to ingress.
46 CFR 179.360(a)
Action required: 705 - Other - as specified
Resolved 30 May 2024
Resolution: Gaskets on main deck above wing deck renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 21 February 2024
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction. 04 total welds cracked on upper deck rail both port and starboard side. Fractured welds on top deck effecting strength of railings. Grind and re-weld rails to provide adequate strength.
46 CFR 177.900(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2024
Resolved 20 May 2024
Resolution: Rails welded and gussets added for support.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 February 2023
Resolved
Each life float must be fitted with a light. The light must be a floating waterlight approved under approval series 161.010. The floating waterlight must be attached by a 3/8inch lanyard resistant to deterioration from UV light and at least 18 feet in length. Life float lights did not meet 161.010 and were not attached by 18 foot line. Provide life floats with approved lights and provide 18 foot line.
46 CFR 180.175(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2023
Resolved 17 March 2023
Resolution: Life float lights provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 March 2022
Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturers instructions. Fireboy override did not function as designed. Make pre-engineered fire extinguishing system function as designed with operational override.
46 CFR 181.420
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2022
Resolution: System fully operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 March 2022
Resolved
On a vessel of not more than 65 feet in length carrying more than 49 passengers, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414kPa (60 psi) at the pump outlet. The pump must be fitted with a pressure gauge. Gauge was inoperable. Fix gauge to reflect psi.
46 CFR 181.300(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2022
Resolution: Operator replaced gauge. Verified psi.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 2 March 2022
Resolved
Deck rails must be designed and constructed to withstand a point load of 200lbs applied at any point in any direction, and a uniform load of 50lbs/ft applied to the top rail in any direction. Discovered 03 cracks in rails on top deck, starboard side. Repair cracks.
46 CFR 177.900(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2022
Resolution: Welds were fixed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 March 2022
Resolved
Vessel does not currently meet the requirements of Work Instruction 31. Mandated crew posted on COI may not enter the water or act as lifeguard until policy and procedure provided. Provide written procedure.
Work Instruction 31
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 April 2022
Resolution: Procedures provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 2 March 2022
Resolved
A mariner may not serve under the authority of an MMC past its expiration date. Expiration date for master was 07 Jan 2022. The movement of vessel shall be under the direction and control of the master at all times. Vessel master operated the vessel 23 days with expired MMC. Vessel must have master must have valid MMC. Provide master with valid MMC for operations.
46 CFR 10.205(c)
46 CFR 185.304
Action required: 705 - Other - as specified
Resolved 4 March 2022
Resolution: Master with valid MMC provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2021
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all supervisory personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2021
Resolved 30 November 2021
Resolution: Supervisors completed required EAP Training.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 24 February 2021
Resolved
(02) sewage valves were missing lock and only had the clip sleeve installed. Secure both overboard sewage valves in accordance with regulations. (i.e. closing each valve leading to an overboard discharge and removing the handle; padlocking each valve leading to an overboard discharge in the closed position; or using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 25 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 February 2021
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. The upper deck containers for life jackets marking deteriorated due to the sun. Repair/Renew upper deck markings for life jacket stowage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 25 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 February 2021
Resolved
Vessel COI indicates requirement for (06) Portable Fire Extinguishers. Vessel [name withheld] indicates (02) extinguishers in the Pilot House (one for the pilot house/one for the upper deck). Vessel must comply with Table 181.500. Vessel has five portable extinguishers installed, and two stowed as extras. Install the sixth extinguisher in accordance with general arrangement.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 2 April 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 February 2021
Resolved
Provide updated vessel electrical one line drawing following installation of additional power outlet to provide proper electrical power source to portable A/C unit in pilot house. Do not operate portable A/C unit with extension cord.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 25 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 January 2019
Resolved
Vessel was missing 4 adult PFDs. Provide PFDs in accordance with 46 CFR 180.71. Vessel limited to 151 total persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 January 2019
Resolution: PFDs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 January 2019
Resolved
Prove valves on port and stbd fuel tank sight glasses will close automatically when sight glass is ruptured in accordance with 46 CFR 182.440(a)(7).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 February 2019
Resolution: Document provided proving sight glass valves are self closing in the event of a failure of the sight glass.
Documentation › Certificates/Documents › Stability Letter
Issued 9 February 2018
Resolved
Provide approved stability from MSC. Obtain stability letter and post as reuired.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2018
Resolved 9 March 2018
Resolution: Recieved signed stability letter from MSC. Sec Pgt Snd sent copy to [name withheld]
Documentation › Logs/Records › Drug Test Records
Issued 9 February 2018
Resolved
Provide evidence of DAPI enrollment for all Masters/Crewmembers working on vessel.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2018
Resolved 23 March 2018
Resolution: Audit complete.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 9 February 2018
Resolved
Provide original MMC for Master of vessel to USCG Inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2018
Resolved 19 March 2018
Resolution: MMC provided.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 9 February 2018
Resolved
Provide evidence of CPR/Frist aid certification for 50% of crew
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2018
Resolved 19 March 2018
Resolution: Certification provided.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 9 February 2018
Resolved
Provide applicable charts and publications pertaining to operating zone.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2018
Resolved 19 March 2018
Resolution: Charts and Pubs provided.
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 February 2018
Resolved
Conduct Fire, Man overboard, and Abandon ship drill
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2018
Resolution: Drills conducted.