Records from 1989 to 2025. Most recent: inspection, 16 May 2025.
Documentation record
Registered dimensions (L × B × D)56.0 ft × 22.0 ft × 8.5 ft
Registered tonnagegross 102 / net 69
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHRIFT SHIPBUILDING & REPAIR INC · SULPHUR, LA, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLAROSE, LA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationCase Pending · issued 23 September 2025 · expires 30 September 2026
Service, as the file records itSchool Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it102 - Regulatory (Subpart C or D), Gross Ton
69 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
16 May 2025
Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8145490
16 May 2025
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8187224
24 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8098570
27 October 2024
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8027266
6 February 2024
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7861743
31 March 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7166432
22 April 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6942476
18 March 2019
Initial Certification · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6690048
13 March 2019
Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6642135
8 March 2019
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6640305
13 October 2006
Uninspected Other · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2799758
5 October 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2794330
29 April 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2345640
6 April 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2331292
6 February 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2025739
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977606
25 March 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 427051
21 January 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 24965
18 May 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 32394
27 November 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 65790
19 November 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 45523
29 November 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 452537
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2025
Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel. Vessel was observed with a steering gear pin improperly secured & backing out from flanking rudder port jockey bar/ram.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: Received objective evidence. See def docs.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 23 April 2025
Resolved
Each device must Be free of design defects such as rough or sharp edges that may cause bodily injuries or that would allow toxic substances to escape to the interior of the vessel. The Marine sanitaion device was observed wasted in areas with temporary repairs made which would allow toxic substances and gas to escape.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: Received objective evidence. See def docs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 April 2025
Resolved
The following systems must be equipped with gauges at the machinery location: Main engine lubricating oil pressure, main engine RPM, and Main engine cooling water temperature. Both main engines were observed without functioning gauges.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 8 May 2025
Resolution: Received evidence of operable gauges.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 April 2025
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Vessel was observed with gasoline in unapproved containers stored unsecured on the 02 deck. Remove fuel containers immediately, 14 days to remedy securing plan and obtain auth. containers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 8 May 2025
Resolution: Fuel cans properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 February 2024
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. Vessel did not have railings or bulwarks on the aft deck. Vessel must install rails or equivalent protection on all spaces accessible to the crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2024
Resolved 27 February 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 February 2024
Resolved
46 CFR 143.400 (d)
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. The engine room's stbd breaker panel was missing breaker labels. Labels need to be added to those missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 9 February 2024
Resolution: Complete label list installed in panel door.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 February 2024
Resolved
46 CFR 143.400 (a)
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. The light switch cover in the aft berthing is missing the light switch cover. Vessel needs to replace the cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 9 February 2024
Resolution: Light cover installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2024
Resolved
46 CFR 16.230 (a)
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members. Vessel did not have established written procedures as to how they are conducting random testing. Vessel needs to establish written procedures regarding random drug testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 21 February 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 November 2019
Resolved
Vessel had an excessive amount of oily water in the bilge creating a fire and pollution hazard. Vessel must pump bilge into either slop tank or facility prior to operation. Vessel is allowed to transit to appropriate facility to clean bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2019
Resolution: Vessel submitted photograghs of bilges pumped dry.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 November 2019
Resolved
Vessel did not have any approved distress signals for Inspected Towing Vessels. Vessel must provide 03 day and 03 night distress signals or an approved combination of both.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2019
Resolution: Received photograph of appropriate distress signals on board
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 November 2019
Resolved
Vessel did not have the MMSI number programmed into either VHF radio installation. Program MMSI number into one of the VHF radios.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2019
Resolved
Vessel had fuel shutoff valves at both MDEs and Ships Service Generators. Vessel is required to have the fuel shutoffs at the fuel tank. Relocate or install new fuel shutoff valve at the fuel tank.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2019
Resolution: Photorgraph was provided of the newly installed fuel shutoffs at the main fuel tank