Records from 1996 to 2024. Most recent: inspection, 18 November 2024.
Inspection history · 17
18 November 2024
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8036341
7 July 2020
Deficiency Check · Re-Inspection · Administrative Inspection · Initial Certification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6999786
22 June 2019
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6752400
22 May 2019
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6697861
13 April 2016
Spot Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5854766
1 April 2014
Spot Check (Safety)
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4803470
24 April 2013
Spot Check (Safety)
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4562380
11 May 2012
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4334589
17 June 2011
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4340888
26 May 2010
Industry Initiated Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3749047
14 March 2006
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2602893
14 March 2006
MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2667527
28 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996419
24 October 1997
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 175374
30 June 1996
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 21361
30 June 1996
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 177285
22 January 1996
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 710181
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 July 2020
Resolved
Life buoy on starboard side pilot house had wasted plug/stopper that made inside foam open to the weather. Life buoy shall be approved under approval series 160.050 or 160.150 Provide life ring in accordance with 46 CFR 141.360 to the satisfaction of the attending Coast Guard
marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2020
Resolved 18 November 2024
Resolution: Not rectified. Vsl out of service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 July 2020
Resolved
Vessel starboard engine keel cooler has an unauthorized epoxy patch repair and additional pin hole leaks. Machinery and electrical systems must be designed and maintained to provide safe operations of the towing vessel and safety of persons onboard under normal and emergency conditions. Conduct satisfactory repairs to keel coolers prior to carrying passengers and prior to departure to the satisfaction of the attending Coast Guard marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 November 2024
Resolution: Not rectified. Vsl out of service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 July 2020
Resolved
Life jackets did not have proper marking of location, missing whistle and light. Life jackets must be readily accessible and the storage container must be marked in block capital letters with quantity. Each life jacket must have a whistle and a light approved under 161.012 or 161.142. Mark/label Life jacket storage with LIFEJACKET and list quantity. Provide each life jacket with a whistle and approved light prior to movement of the vessel to the satisfaction of the attending Coast Guard marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 November 2024
Resolution: Not rectified. Vsl out of service.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 7 July 2020
Resolved
Vessel does not have an installed fire detection system. Each towing vessel must have a fire detection system installed to detect engine room fires. Each detector control panel and fire alarm are approved by the Commandant under approval series 161.002 or listed by a NRTL as set forth in 29CFR1910.7. Install approved fire detection system as per 46CFR142.330 to the satisfaction of the attending Coast Guard inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2020
Resolved 18 November 2024
Resolution: Not rectified. Vsl out of service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 July 2020
Resolved
Rudder angle indicator electrical connection on stern of vessel has electrical tape securing the plug connection. Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Electrical cables must be suitably protected from wet and corrosive environments. Secure electrical connection with heat shrink for protection from weather to the satisfaction of the attending Coast Guard marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2020
Resolved 18 November 2024
Resolution: Not rectified. Vsl out of service.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 7 July 2020
Resolved
The bolts and nuts to the ladder leading from the galley to the pilot house are rusted or have fallen off. The ladder is currently being held in place by wire on one side. The owner must implement procedures to identify and mitigate health and safety hazards including slips, trips and falls. Install ladder as designed with appropriate nuts and bolts to the satisfaction of the attending Coast Guard inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2020
Resolved 18 November 2024
Resolution: Not rectified. Vsl out of service.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2019
Resolved
Provide an additional fire hose with quick connect fittings that meets the requirements set forth in 46 CFR 142.325 that can readily be deployed and connected with one of the two (02) hoses already in place on the QUEEN, in the event of a fire on board the ITV JANET E. The hose must be lined commercial fire hose 50 feet in length, at least 1.5 inches in diameter, and fitted with a nozzle made of corrosion resistant material capable of providing a solid stream and a spray pattern.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 17 June 2019
Resolution: New fire hose provided in approved location.