Inspection record

Last inspected 28 June 2024
…with no type recorded11
Operational controls None recorded without a removal date
Years with a record 39 calendar years (1986–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

267701
Flag
UNITED STATES
Tonnage
97 - Regulatory (Subpart C or D), Gross Ton 97 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-267701
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 8

Inspection history · 83

28 June 2024 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7944314
1 November 2023 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7819967
17 May 2023 Deficiency Check · In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7690575
1 May 2022 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7428678
1 April 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7166936
18 May 2020 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6955021
22 June 2019 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6752400
22 May 2019 DAPI Audit · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6690843
24 October 2018 Administrative Inspection · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6571691
8 May 2018 DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6409979
1 March 2017 COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6096457
13 April 2016 Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5856547
27 April 2015 DAPI Audit · Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5111456
1 April 2014 MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4803452
24 October 2013 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4739749
1 October 2013 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4710015
1 September 2013 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4730467
11 May 2012 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4334589
2 March 2012 Deficiency Check · MTSA Verification · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4234208
15 August 2011 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4120255
17 June 2011 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4340888
29 March 2010 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3704982
10 March 2010 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3696835
11 June 2009 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3501059
9 March 2009 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3430415
23 December 2008 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3411608
19 November 2008 Drydock Extension
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3365991
16 May 2008 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3208529
16 May 2008 Damage Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3211070
18 March 2008 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3172349
10 October 2007 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3077022
5 April 2007 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2902158
9 March 2007 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2882028
9 March 2007 MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2884954
9 March 2007 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2890505
14 March 2006 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2599486
25 May 2005 MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2374707
10 March 2005 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2307079
16 March 2004 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2015506
24 February 2004 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2011965
28 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996426
13 November 2003 Hull Examination · Internal Structural Exam · Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1954783
18 March 2003 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1759675
12 March 2002 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1493292
21 March 2001 Re-Inspection · Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1471610
7 February 2001 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1410500
14 March 2000 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1369578
21 April 1999 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1125068
23 March 1999 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1450253
30 March 1998 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1428922
5 June 1997 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1113780
8 April 1997 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1101070
8 April 1997 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1416487
22 January 1997 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1099689
23 October 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1166886
9 July 1996 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1088633
30 June 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1084547
30 April 1996 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1081300
20 March 1996 COI Inspection · Drydock Extension
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1083454
15 March 1995 COI Inspection · Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 833587
6 April 1994 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 857148
22 March 1994 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1165744
8 May 1993 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 830928
30 March 1993 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1149898
13 March 1992 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 953974
20 February 1992 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1260425
20 August 1991 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1255579
5 March 1991 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 930368
27 February 1991 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 925882
6 February 1991 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 899973
6 February 1991 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1317205
2 March 1990 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 927180
30 January 1990 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 925698
9 March 1989 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 888265
9 March 1989 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1027034
7 April 1988 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 995371
28 December 1987 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1005490
24 April 1987 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1007559
28 August 1986 Deficiency Check
Physical examination · MSO CINCINNATI · Activity 1007711
14 July 1986 Deficiency Check
Physical examination · MSO CINCINNATI · Activity 1297274
13 June 1986 Type not recorded
No type recorded · MSO CINCINNATI · Activity 1300706
23 May 1986 Deficiency Check
Physical examination · MSO CINCINNATI · Activity 985374
2 May 1986 Initial Certification
Physical examination · MSO CINCINNATI · Activity 1295581

Deficiency record · 89

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 November 2023 Resolved
Vessel did not receive a dry dock exam by the October 31 2023 deadline on its COI. The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys required by this section. Owner shall make vessel available for drydock exam prior to carrying passengers, to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2024
Resolution: Required inspections not completed. COI expired. Vessel removed from commercial service.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 May 2023 Resolved
Fire Main had two leaks, one fitting on main deck and one at the fire plug on the second deck. All piping, valves and fittings shall be accordance with good marine practices and suitable for its intended purpose. Make repairs to the satisfaction of the attending Coast Guard marine inspector
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 17 June 2023
Resolution: Fire main repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2023 Resolved
Ring Life Buoys name of vessel were missing or faded. Each ring life buoy must be marked in clearly legible block capital letters with the vessel name. Make correction to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 17 June 2023
Resolution: Life ring name replaced.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 May 2023 Resolved
Owner did not have crew available to perform drills during the annual inspection. The scope of the annual inspection is the same as the inspection for certification but in less detail The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway. Perform fire, man overboard and abandon ship drills prior to carrying passengers to the satisfaction of the attending Coast Guard marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2024
Resolution: Required drill not complete. COI expired. Vessel removed from commercial service.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 3 June 2022 Resolved
Master has not performed underway fire drills for Coast Guard Marine inspector. The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Master shall perform underway fire drills to the satisfaction of the attending Coast Guard Marine inspector prior to 03 Aug 2022.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2022
Resolved 19 August 2022
Resolution: Observed satisfactory fire drill.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 June 2022 Resolved
Master has not performed underway man overboard and abandon ship drills for Coast Guard marine inspector. The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Master shall perform underway drills to the satisfaction of the attending Coast Guard Marine inspector prior to 03 Aug 2022.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2022
Resolved 19 August 2022
Resolution: Observed satisfactory man overboard.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 June 2022 Resolved
Master has not demonstrated underway navigation which include vessel handling characteristics in presence of Coast Guard marine inspector. The master shall operate the vessel keeping the safety of the passengers and crew foremost in mind by directing the vessel in order to preventing a marine casualty. Master shall demonstrate vessel navigation to the satisfaction of the attending Coast Guard marine inspector prior to 03 Aug 2022.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2022
Resolved 19 August 2022
Resolution: Vessel conducted man overboard and vessel handling.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 May 2022 Resolved
Vessel fire hose nozzle are plastic are not the required type. Each combination solid stream and water spray firehose nozzle required to be approved under the provisions of this subpart must be of brass or bronze, except for hardware and other incidental parts, which may be of rubber, plastic, or stainless steel, and designed, constructed, tested, and marked in accordance with the requirements of ASTM F 1546 or NFPA 1964. Provide fire hose nozzle in accordance with 46 CFR 118.320 to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2022
Resolved 26 May 2022
Resolution: Appropriate fire nozzle installed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 20 May 2022 Resolved
Owner failed to provide training records for crew. The owner, charterer, master, or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 122.510, when applicable, the duties listed in the station bill required by § 122.514. Provide records of crew training to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2022
Resolved 26 May 2022
Resolution: Onwer provided training records.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 20 May 2022 Resolved
Owner failed to provide records of abandon ship or man overboard. The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2022
Resolved 26 May 2022
Resolution: Owner provided training records.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 May 2022 Resolved
Vessel bilge system was not operational during inspection. A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Make repairs to bilge systems and make available for inspection to the satisfaction
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2022
Resolution: Bilge was found to be operational.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 May 2022 Resolved
Owner failed to provide records compliance with drug and alcohol program, pre-employment testing and random testing. Provide drug and alcohol testing requirement to the satisfaction of the attending Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 19 August 2022
Resolution: Pre-employment verified
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 20 May 2022 Resolved
Forward number 1 void hatch was leaking due to lack lack of maintenance on hatch cover and gasket. Each hatch exposed to the weather must be watertight. Conduct maintenance and repairs to number 1 void hatch to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2022
Resolved 19 August 2022
Resolution: Gasket renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2022 Resolved
Master has not demonstrated power bilge pumps driven by two generators. If both of the required fixed power bilge pumps are electrically driven two generators shall be provided. Maser shall demonstrate bilge pump
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2022
Resolved 19 August 2022
Resolution: Two sources of power verified.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 1 May 2022 Resolved
Vessel does not have written senior deckhand policy/training demonstrating increased knowledge and skill of senior deckhand as required by the the Certificate of Inspection. Training and qualification needs to be commensurate with the duties of the senior deckhand duties. Provide senior deckhand policy/training in accordance with NVIC-91 to the satisfaction of the attending Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2022
Resolved 19 August 2022
Resolution: Owner will not use senior deck hand. A licensed pilot will be onboard while vessel is operating with passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2021 Resolved
Number 2 void bilge valve on the bilge manifold has a pin whole leak preventing de-watering of the space. Every vessel must be provided with a satisfactory arrangement for draining any water tight compartment. Replace bilge manifold vale to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2021
Resolved 16 April 2021
Resolution: Tested new bilge valve with satisfactory results.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2019 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length but not more than 6 feet, securing the waterlight around the body of the ring life buoy.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 17 June 2019
Resolution: Replaced line and lanyard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 May 2019 Resolved
Each life jacket kept in a storage container must be readily available. Replace rusted latch on the aft storage container, 2nd deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 17 June 2019
Resolution: Replaced storage container with new.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 May 2019 Resolved
Remove and/or replace expired items in the first aid kit and ensure that the kit meets the minimum requirements in 46 CFR 160.041 (attached) or an equivalent.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 17 June 2019
Resolution: Replaced in kind.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 8 May 2018 Resolved
B-II fire extinguisher did not have charge.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 June 2018
Resolved 8 May 2018
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 1 March 2017 Resolved
Each life jacket kept in a stowage container must be readily available. Latches on top deck have been painted over preventing them from opening.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 23 May 2017
Stability › Watertight Integrity › General
Issued 1 March 2017 Resolved
Any hatch exposed to the weather must be watertight IAW 46 CFR 116.1160
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 23 May 2017
Operations/Management › Drills/Instruction › Abandon Ship
Issued 1 March 2017 Resolved
Due to the river conditions, a man overboard drill and fire drill were not conducted during your vessel’s COI. Please schedule a follow up with this office prior to the due date.
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 23 May 2017
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 1 March 2017 Resolved
Contact your company’s drug program consortium to request proof of acceptable DOT five-panel testing implementation.
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 23 May 2017
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 1 March 2017 Resolved
Contact your company’s drug program consortium to request proof of CY 2015 and if available 2016 Management Information System (MIS) report submission.
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 8 May 2018
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 April 2014 Resolved
Make necessary repairs and demonstrate proper operation of the floating water light in way of the life ring buoy to the satisfaction of an attending Coast Guard Marine Inspector. Vessel is restricted to daylight operations until repairs are completed and verified.
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 3 April 2014
Resolution: Witnessed operation of the floating water light.
Construction/Loadline › Structures › Scupper
Issued 1 October 2013 Resolved
Replace wasted drain pipe outlet located on the stern of the vessel servicing the drain to the bar sink to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 1 November 2013
Resolved 24 October 2013
Resolution: Existing drain pipe was removed and the area cleaned. A new pipe was installed and inspected satisfactorily.
Construction/Loadline › Structures › Scupper
Issued 1 October 2013 Resolved
Replace wasted drain pipe outlet located on the starboard side, aft of the MN03 - Replace wasted drain pipe outlet located on the starboard side, aft of the vessel servicing the drain to the male head to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 1 November 2013
Resolved 24 October 2013
Resolution: Existing drain pipe was removed and the area cleaned. A new pipe was installed and inspected satisfactorily.
Construction/Loadline › Hull › Longitudinal Frame
Issued 1 October 2013 Resolved
Crop and Renew the buckled and tripped bulkhead stiffener located on the port side in the Forepeak Tank, #1 void. The frame should be cropped from the deck to a minimum of 18 inches high as marked and discussed with the vessel representative. Repairs should be completed to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 1 November 2013
Resolved 24 October 2013
Resolution: A new bulkhead stiffener was installed and inspected satisfactorily.
Stability › Watertight Integrity › General
Issued 1 October 2013 Resolved
Provide a captive chain in way of the watertight hatch on the bow deck to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 1 November 2013
Resolved 24 October 2013
Resolution: Captive chain was installed to the watertight hatch in way of the fore peak tank.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 March 2012 Resolved
Replace all expired medication s in the first aid kit and ensure the first aid kit has all the required contents in accordance with 33 CFR 160.041.
Action required: 705 - Other - as specified
Due 2 April 2012
Resolved 23 April 2012
Resolution: All expired medications were removed and first aid kit had sufficient contents in accordance with 46 CFR 160.041
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 March 2012 Resolved
Demonstrate proper operation of the floating water light attached to one of the required life ring buoys prior to carrying passengers during night time operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2012
Resolved 23 April 2012
Resolution: Floating water light was tested and found to be operational.
Communications › Public Address System › Amplifier
Issued 2 March 2012 Resolved
During operational test of the Public Address System, the Masters voice could only be faintly heard. Make necessary repairs to the fixed Public Address System on board and demonstrate proper operation to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 2 April 2012
Resolved 23 April 2012
Resolution: A new public address system was installed and tested.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2012 Resolved
Ensure all wiring and any splices of the associated wiring are properly secured in accordance with 46 CFR 120.340(i). Observed improper splices on the speaker wire located on the portside upper deck along the canopy and an electrical fan in the women's head.
Action required: 705 - Other - as specified
Due 2 April 2012
Resolved 23 April 2012
Resolution: All wirning was properly spliced and secured.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 March 2010 Resolved
Line attached to lifebuoys needs to be replaced, the line started to deteriorate and was not resistant to ultraviolet light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 29 March 2010
Resolution: Owner has replaced float-line with 100'' of new line.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 March 2010 Resolved
Free latches on two of the lifejack lockers that were found to be painted over and not free.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 March 2010
Resolved 10 March 2010
Electrical › Lighting (service) › Outlet Box
Issued 9 March 2009 Resolved
Outlet box topside, Aft, missing due to weather.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 April 2009
Resolved 11 June 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 9 March 2009 Resolved
One light fixture midships Port side needs to be repaired and one has water in the glass cover.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 April 2009
Resolved 11 June 2009
Accommodation/Occupational Safety › Potable Water System › General
Issued 23 December 2008 Resolved
Potable water line running through voids needs replaced due to fracture caused by freezing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2009
Resolved 9 March 2009
Resolution: Potable water line replace and inspected. Satisfactory condition.
Construction/Loadline › Hull › Side Shell
Issued 16 May 2008 Resolved
make permanent repairs to forward port quarter in way of damage from brage breaking away from moorings up river and colliding with vessel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 January 2009
Resolved 21 January 2009
Lifesaving › Lifebuoys › Serviceable
Issued 9 March 2007 Resolved
Replace two life buoys on the passenger barge QUEEN and add a floating light to one, also replace one life buoy on the towing vessel JANET E.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2007
Resolved 10 October 2007
Lifesaving › Lifejacket/PFD (Type II) › Marking
Issued 9 March 2007 Resolved
Install lifejacket donning instructions at all lifejacket lockers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2007
Resolved 5 April 2007
Resolution: Instructions installed.
Construction/Loadline › Hull
Issued 13 November 2003 Resolved
Vessel must conduct corrosion survey and evaluation of electrical equipment installations on board to determine cause and corrective actions needed to stop/arrest corrosive pitting of hull. Documents/reports relating to this survey must be submitted to OCMI Louisville. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 24 February 2004
Resolution: Received fax documenting electrical work/testing performed in an effort to remedy vessel hull corrosion/erosion problems. Deficiencies were found and corrected.
Communications › Audible Communications
Issued 12 March 2002 Resolved
Replace or repair Public Address System for internal communications. LEGACY COMPONENT DESC: Public Address System
Condition: Unknown
Due 12 April 2002
Resolved 15 March 2002
Resolution: Made repairs to existing system, conducted test unit found to be operating satisfactory.
Accommodation/Occupational Safety › Occupational Safety
Issued 12 March 2002 Resolved
Replace hinge pin/bolt on boom used to lift forward gangway. LEGACY COMPONENT DESC: Forward Gangway Lifting Boom
Condition: Unknown
Due 12 April 2002
Resolved 15 March 2002
Resolution: Installed new bolt for boom, weight tested satisfactory.
Electrical
Issued 21 March 2001 Resolved
REPLACE MISSING FACE PLATE FOR LIGHT SWITCH ON AFT SIDE OF BULKHEAD BEHIND BAR.
Condition: Unknown
Due 21 April 2001
Resolved 30 May 2001
Lifesaving
Issued 21 March 2001 Resolved
RESTENCIL VESSEL NAME ON RING BUOY.
Condition: Unknown
Due 21 April 2001
Resolved 30 May 2001
Construction/Loadline
Issued 21 March 2001 Resolved
LABEL BILGE HIGH LEVEL ALARM.
Condition: Unknown
Due 21 April 2001
Resolved 30 May 2001
Lifesaving
Issued 21 March 2001 Resolved
INVENTORY FIRST AID KIT AND REPLENISH AS NECESSARY.
Condition: Unknown
Due 21 April 2001
Resolved 30 May 2001
Electrical
Issued 21 March 2001 Resolved
MISSING 3 DECK/COURTESY LIGHT FIXTURES ON TOP DECK, REPLACE OR PROPERLY TERMINATE WIRES AND CLOSE FIXTURES.
Condition: Unknown
Due 21 April 2001
Resolved 30 May 2001
Construction/Loadline
Issued 23 March 1999 Resolved
INSTALL BILGE HIGH LEVEL ALARM IN COMPT #8 IN ACCORDANCE WITH 46CFR119.530.
Condition: Unknown
Due 23 March 1999
Resolved 23 March 1999
Documentation
Issued 30 March 1998 Resolved
PROVIDE AND POST EAP INFORMATION PER 46 CFR 16.401.
Condition: Unknown
Due 13 April 1998
Resolved 17 April 1998
Documentation
Issued 30 March 1998 Resolved
SUBMIT THE REQUIRED ANNUAL DRUG TESTING REPORT PER 46 CFR 16.500.
Condition: Unknown
Due 13 April 1998
Resolved 17 April 1998
Electrical
Issued 8 April 1997 Resolved
Demonstrate proper function of public address system to the satisfaction ofthe attending CG marine inspector.
Condition: Unknown
Due 8 April 1997
Resolved 8 April 1997
Electrical
Issued 30 June 1996 Resolved
THE GENERATOR ABOARD THE M/V JANET E FAILED TO HOLD THE ELECTRICAL LOAD UNDER NORMAL OPERATING CONDITIONS DUE TO OVERHEATING. THIS GENERATOR PROVIDES ELECTRICAL POWER FOR THE INSPECTED PASSENGER BARGE QUEEN.
Condition: Unknown
Due 3 July 1996
Resolved 3 July 1996
Navigation
Issued 15 March 1995 Resolved
PROPERLY FASTEN LINE SHAFT BEARING TO STEERING/RUDDER LINKAGE BELOW PILOT HOUSE ON JANET E.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Electrical
Issued 15 March 1995 Resolved
REMOVE JURY RIGGED LIGHTS FROM TOP MAIN DECK AFT ABOVE PORT AIR HANDLER.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Electrical
Issued 15 March 1995 Resolved
INSTALL ELECTRICAL MATTING BELOW SWITHBOX MOUNTED ON THE BULKHEAD ABOVE NO.8 VOID SPACE.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Fire Fighting
Issued 15 March 1995 Resolved
INSTALL DIAGRAM OF MANIFOLD FOR BILGE PIPING SYSTEM WHICH INCLUDES GASOLINEPOWERED PUMP AND LABELING OF ALL VALVES FOR APPROPRIATE SPACES.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Lifesaving
Issued 22 March 1994 Resolved
PROPERLY REPAIR DISCHARGE PIPE NIPPLE FROM POTABLE FRESHWATER TANK ON M/V "JANET E", TO PREVENT WATER SPRAY ON AN ELECTRICAL POWER PANEL.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Documentation
Issued 22 March 1994 Resolved
UPDATE POSTED DESIGNATED SENIOR DECKHAND LIST
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Construction/Loadline
Issued 22 March 1994 Resolved
DEWATER #7 COMPARTMENT OF 1 INCH OF WATER CAUSED BY A PREVIOUSLY BROKEN DOMESTIC WATER PVC DRAIN PIPE.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Electrical
Issued 22 March 1994 Resolved
PROPERLY WIRE AND RELOCATE ELECTRICAL JUNCTION BOX FROM FIRE AND BILGE PUMPDISCHARGE PIPING CONFIGURATION IN # 8 COMPARTMENT. WIRING LEADS TO A 12 VOLT, HIGH LEVEL INDICATOR, FOR THE SEWAGE HOLDING TANKS.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Construction/Loadline
Issued 22 March 1994 Resolved
DEMONSTRATE SATISFACTORY OPERATION OF SECONDARY FIRE AND BILGE PUMP.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 30 March 1993 Resolved
COMPLETED SATISFACTORY MAN OVERBOARD DRILLS AND FIRE DRILLS.
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Electrical
Issued 30 March 1993 Resolved
PRIOR TO NAVIGATING VESSEL, DEMONSTRATE SATISFACTORY OPERATION OF TWO-WAY COMMUNICATIONS BETWEEN JANET E. AND BOW LOOKOUT OF QUEEN.
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Navigation
Issued 30 March 1993 Resolved
PROPERLY INSTALL PORT, STBD, AND FLASHING AMBER NAVIGATION LIGHTS WHICH CONFORM TO THE 1972 COLREGS, NOT LATER THAN THE COMPLIANCE DATE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Documentation
Issued 30 March 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Lifesaving
Issued 30 March 1993 Resolved
MAKE AVAILABLE FOR INSPECTION, RESCUE BOAT, LIGHT FOR RING BUOY, AND LICENSES PRIOR TO NAVIGATING VESSEL.
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Navigation
Issued 30 March 1993 Resolved
COMPLETE OPERATIONAL TESTS OF M/V JANET E's STEERING AND NAVIGATION EQUIPEMENT PRIOR TO NAVIGATING BARGE QUEEN.
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Lifesaving
Issued 20 February 1992 Resolved
REPLACE DETERIORATED UPPER DECK LIFE PRESERVER STOWAGE BOXES NOT LATER THANTHE COMPLIANCE DATE._x001C_
Condition: Unknown
Due 20 February 1992
Resolved 20 February 1992
Lifesaving
Issued 20 February 1992 Resolved
PROVIDE TWO ADULT LIFE PRESERVERS NOT LATER THAN THE COMPLIANCE DATE. VESSEL IS RESTRICTED TO THE CARRIAGE OF NOT MORE THAN 426 PERSONS UNTIL TWOADDITIONAL APPROVED LIFE PRESERVERS ARE PLACED ONBOARD.
Condition: Unknown
Due 20 February 1992
Resolved 20 February 1992
Lifesaving
Issued 20 February 1992 Resolved
REPLACE THE DETERIORATED RING BUOY ONBOARD THE M/V JANET E. PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 20 February 1992
Resolved 20 February 1992
Electrical
Issued 20 February 1992 Resolved
REPLACE CLOUDED GAUGE BOX COVERS ON MAIN GENERATOR ONBOARD THE M/V JANET E.NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 20 February 1992
Resolved 20 February 1992
Lifesaving
Issued 20 August 1991 Resolved
PROVIDE THREE APPROVED ADULT LIFE PRESERVERS PRIOR TO THE COMPLIANCE DATE. TOTAL PERSONS ONBOARD IS RESTRICTED TO 425 UNTIL THREE COAST GUARD INSPECTED AND STAMPED LIFE PRESERVERS ARE PLACED ONBOARD.
Condition: Unknown
Due 20 August 1991
Resolved 20 August 1991
Engineering
Issued 27 February 1991 Resolved
RENEW CRIMPED FUEL HOSE TO SERVICE GENERATOR WITH USCG ACCEPTED TYPE (ON M/V JANET E.) PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Electrical
Issued 27 February 1991 Resolved
INSTALL MISSING BULB IN AFT EMERGENCY LIGHT FIXTURE PRIOR TO THE COMPLIANCEDATE.
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Unknown
Issued 24 April 1987 Resolved
DEWATER THE POTABLE WATER TANK AND COAT WITH AN APPROVED COATING.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Lifesaving
Issued 13 June 1986 Resolved
PROVIDE STORAGE FOR THE CHILDREN'S LIFE JACKETS AND PROPERLY MARK STORAGE.
Condition: Unknown
Due 13 June 1986
Resolved 13 June 1986
Lifesaving
Issued 23 May 1986 Resolved
THE VESSEL IS RESTRICTED TO THE CARRIAGE OF 400 ADULTS UNTIL THE 30 ADDI- TIONAL LIFE JACKETS ARE INSPECTED AND STAMPED.
Condition: Unknown
Due 23 May 1986
Resolved 23 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE "AS IS" DRAWINGS OF THE MAIN DECK AND GENERAL HULL ARRANGEMENT.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Electrical
Issued 2 May 1986 Resolved
PROVIDE WATERTIGHT ELECTRICAL FIXTURES FOR OUTSIDE OUTLETS.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE A DEVICE TO INDICATE WHEN THE SEWAGE RETENTION TANKS ARE 3/4 FULL.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Electrical
Issued 2 May 1986 Resolved
REPAIR THE EXHAUST LEAK ON THE NO. 5 CYLINDER ON THE MAIN GENERATOR.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE EVIDENCE THAT THE ON BOARD CARPETING IS ASTME-84 TESTED.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Electrical
Issued 2 May 1986 Resolved
WORK UP A COMPLETE ELECTRICAL LOAD ON THE MAIN GENERATOR ON BOARD THE CAP- TAIN AND PROVIDE THIS INFORMATION TO THIS OFFICE.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Lifesaving
Issued 2 May 1986 Resolved
PROVIDE THE PROPER NUMBER OF LIFE RINGS ON BOARD THE JUBILEE QUEEN AND AC- COMPANYING TOWBOAT.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Fire Fighting
Issued 2 May 1986 Resolved
REPAIR OR REPLACE AS NECESSARY THE ON BOARD FIRE AND BILGE PUMPS TO PROVIDETHE MINIMUM CAPACITIES AND PRESSURES.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVE, IN THE PRESENCE OF A COAST GUARD INSPECTOR, THE PROPER OPERATION ANDHANDLING OF THE TOWBOAT CAPTAIN AND JUBILEE QUEEN. THIS ITEM IS TO BE COM-PLETED PRIOR TO OPERATING THE VESSEL AND M/V [name withheld] ING TOW.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986